Results 1 to 20 of 426 for “"Time-Of- Flight - ToF"”
-
SPAD-Based Time-of-Flight (ToF) Depth Sensor for LiDAR Applications
… avalanche diode (SPAD)-based direct time-of-flight (d-ToF) light detection and ranging (LiDAR) sensors, targeting automotive urban-driving applications. In complex urban scenarios, LiDAR performance is critically degraded by strong ambient illumination, dominated by sunlight, and …
-
Fusion of time of flight (ToF) camera's ego-motion and inertial navigation.
For mobile robots to navigate autonomously, one of the most important and challenging task is localisation. Localisation refers to the process whereby a robot locates itself within a map of a known environment or with respect to a known starting point within an unknown environment. Localisation of …
-
Laser-driven implosion characterization by the analysis of charged-fusion-product energy spectra
Energy spectra of charged-fusion products escaping laser-imploded deuterium-tritium filled glass microballoon targets were measured with a time-of-flight (TOF) spectrometer. The TOF spectrometer was carefully designed, constructed and calibrated to simultaneously measure alpha-particles and protons.
-
Studies of oriented molecules using coincidence time-of-flight mass spectroscopy
A beam of symmetric top (CX3Y) molecules is state-selected using an inhomogeneous hexapole electric field and then oriented by homogeneous electric fields. A fast neutral atomic potassium beam produced via charge-exchange crosses the molecular beam at a right angle. Continuous electric fields …
-
A large area time of flight detector for the STAR experiment at RHIC
A large area time of flight (TOF) detector based on multi-gap resistive plate chamber (MRPC) technology has been developed for the STAR (Solenoidal Tracker at RHIC) experiment at the Relativistic Heavy Ion Collider at the Brookhaven National Laboratory, New York. The TOF detector replaces STAR's …
-
COINCIDENCE DETECTION OF PROTONS AND METASTABLE HYDROGEN ATOMS FROM DISSOCIATIVE IONIZATION OF MOLECULAR HYDROGEN BY ELECTRON IMPACT (TIME-OF-FLIGHT).
… and H⁺ fragments resulting from the bombardment of H₂ with 100 eV electrons. A significant source of this coincidence is believed to be the 2sσ(g) state of H₂⁺. The time-of-flight (TOF) distribution of H(2S) fragments from the 2sσ(g) state was measured and converted to the kinetic energy …
-
Desenvolvimento de um sistema de aquisição de informações volumétricas usando métodos de triangulação a laser e campo de visão variável
… 3D acquisition systems use the principle of laser triangulation or the principle of time of flight TOF. In the systems based on triangulation, the range and the depth variation are very limited, but it has a great precision. On the other hand the opposite occurs to the TOF systems where it …
-
MALDI-TOF MS Data Processing Using Wavelets, Splines and Clustering Techniques.
… assisted laser desorption/ionization (MALDI) time of flight (TOF), is emerging as a leading technique in the proteomics revolution. It can be used to find disease-related protein patterns in mixtures of proteins derived from easily obtained samples. In this paper, a novel algorithm for …
-
A Wavelet Based Method for ToF Camera Depth Images Denoising
This work addresses the problem of shot noise in Time-of-Flight (ToF) camera depth sensors, which is caused by the random nature of photon emission and detection. In this paper, we derive a Bayesian denoising technique based on Maximum A Posteriori (MAP) probability estimation, implemented in the …
-
The Study of (gamma, n) Reactions in Light Nuclei at Intermediate Photon Energy
… in this thesis describes an experimental study of (gamma,n) reactions on 16O and 6Li nuclei using 50-70 MeV tagged photons. At this photon energy range, the so-called intermediate energy region, the photon absorption mechanism is not quantitatively established, but it is thought that pion- …
-
The Design and Construction of a Surface Analysis Station (Part A)
… The design, construction, and initial operation of a surface analysis station were undertaken. The final UHV system is equipped for ion surface scattering, low energy electron diffraction, Auger analysis, secondary ion mass spectroscopy and residual gas analysis. </p> <p> The main goal of this …
-
Calibration of the STAR Time-of-Flight Detector for Particle Identification
This thesis describes several calibrations of the Time-of-Flight (TOF) detector at the Solenoidal Tracker at RHIC (STAR). These calibrations are required to allow Particle Identification (PID) which benefits many physics analysis. These calibrations treat the Integral Non-Linearity (INL) of the …
-
Inclusive charged kaon production from B mesons in Upsilon(4S) decays.
… we have investigated the inclusive production of charged kaons, in the decays of B mesons. We present results of the measurement of the charged kaon momentum spectrum from B decays, using information from Specific Ionization Energy Loss (dE/ dx) and Time-of-Flight (ToF) Particle Identification …
-
Signal and image processing methods for imaging mass spectrometry data
… thesis focuses on algorithms for the analysis of IMS data produced by matrix assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometer. IMS provides mass spectra acquired at a grid of spatial points that can be represented as hyperspectral data or a so-called datacube. …
-
Peer-to-peer wireless ultrawide-band localization of fast-moving entities
… localization techniques such that a group of mobile nodes can continuously track its topology, without relying on external infrastructure. Ultrawide-band (UWB) radios worn by each node (humans in our case) perform time-of-flight (TOF) measurements between different node pairs, ultimately …
-
Application of time-of-flight velocity selection to metastable de-excitation spectroscopy
… Spectroscopy (MDS) provides a valuable probe of surface electronic and magnetic structure. Spin labelling of the excited electron can yield additional information about the de-excitation mechanisms. In such experiments, neon ($\sp3$P$\sb2$) and argon ($\sp3$P$\sb2$) metastable atoms are …
-
Rendezvous and formation flying related to the TECSAS mission
… formation flying were examined in context of the TECSAS mission. Three terminal rendezvous trajectories, one V-bar approach and two R-bar approaches, are compared in terms of DeltaV fuel usage and time of flight (TOF). Results showed that the lidar-based V-bar approach trajectory with a 90 …
-
Rigid body pose estimation using multiple ultra-wideband ranging and angle-of-arrival measurements
… Ultra-wideband (UWB) sensing provides accurate Time-of-Flight (ToF) ranging and Angle-of-Arrival (AoA) measurements, offering complementary information for relative localization. However, existing UWB-based pose estimation methods typically rely on nonlinear optimization and are sensitive to …
-
MDS-based method for rigid body pose estimation using ToF
… is widely used in indoor positioning because of its high ranging accuracy. However, rigid-body pose estimation becomes challenging when only time-of-flight (ToF) measurements are available, especially under incomplete link conditions. To address this problem, this thesis proposes an MDS-based …
-
A Time of Flight on-Robot Proximity Sensing System for Collaborative Robotics
… presented in this work demonstrates the results of designing an industrial grade exteroceptive sensing device for proximity sensing for collaborative robots. The intention of this design's application is to develop an on-robot small footprint proximity sensing device to prevent safety protected …
Page 1 of 22