Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 30 for “"Time-Of-Flight measurement"”
-
Determination of Wound Roll Structure Using Acoustic Time of Flight Measurement�
Roll structure measurement is presently done with destructive and intrusive measuring devices, such as Force Sensing Resistors (FSR) [1] or with specially instrumented winders. These methods are generally limited to research and development applications. Prior to this project, there was no method …
-
Development of a novel ultrasound monitoring system for container filling operations
… for measuring the liquid level in containers are often carried out downstream of the filling operation. While these methods meet the requirements of Trading Standards Legislation, they contribute very little to improving the real-time control of the filling process. Among the measurement …
-
An apparatus for electron impact ionization cross-section measurements
Cross sections for electron impact ionization of molecules and rare gases are necessary for the modeling of phenomena related to the earth's upper atmosphere and to plasmas. The construction of an apparatus to improve the accuracy of measurements of such cross sections is reported. The ions are …
-
Determination of the angular distribution of cosmic rays at sea level
… order to measure the zenith angular distribution of cosmic ray muons at sea level. The setup consists of two long scintillator counters with double-ended readout. Previous measurements have shown that the intensity of muons obey the cos 2 0 distribution. In this thesis, two methods are used. The …
-
Single pi-zero production in neutrino interactions
Production of single pio particles in neutrino reactions has been studied in an experiment at the Brookhaven National Laboratory Alternating Gradient Synchrotron. The neutral current reactions, vn -> vnpio and vp + vprr , and the charged current reaction, vn -> u-ppi0 ,were investigated. The …
-
A Source-Based Test-Bed for Fast-Neutron Irradiation
… neu- tron and with a substantially lower cost of entry. A drawback associated with radioac- tive sources is the associated isotropic mixed neutron/gamma-ray field. This work in- troduces a cost-efficient test-bed for the production of 2-7 MeV neutrons based on an 241Am/9Be source, with the aim …
-
3D imaging via binary wavefront modulation for lidar and machine vision applications
… We first demonstrate colorful 3D imaging via time of flight measurements in order to map the target scene to a 3D point cloud data and secondly perform triangulation method. For time of flight measurements, we employ a digital micro-mirror device with a resolution of 1920x1080 and a range …
-
AI for time-resolved imaging: from fluorescence lifetime to single-pixel time of flight
Time-resolved imaging is a field of optics which measures the arrival time of light on the camera. This thesis looks at two time-resolved imaging modalities: fluorescence lifetime imaging and time-of-flight measurement for depth imaging and ranging. Both of these applications require temporal …
-
Search for slow charged long-lived particles with the ATLAS detector at the LHC.
… data, corresponding to integrated luminosities of 140 fb−1 at √s= 13 TeV and 169 fb−1 at √s= 13.6 TeV. The analysis relies on independent measurements of the particle mass from the ionisation in the Inner Detector and the Muon Spectrometer and the time-of-flight in the Muon Spectrometer and the …
-
Fully Distributed Multi-parameter Sensors Based on Acoustic Fiber Bragg Gratings
… their widespread applications. A novel concept of acoustic fiber Bragg grating (AFBG) is conceived with inspiration from optical fiber Bragg grating (FBG). This AFBG structure exploits periodic spatial perturbations on an elongated waveguide to sense variations in the spectrum of an acoustic …
-
Thermal Microfluidic Devices; Design, Fabrication and Applications
… the thermal actuation and temperature measurement methods in microfluidic devices. We designed and fabricated microfluidic devices with various functionalities such as: bio sensing, particle counting, microscale calorimetry, and cellular temperature measurement. All of these …
-
An FPGA-based trigger processor for a measurement of deeply virtual compton scattering at the COMPASS-II experiment
… COMPASS-II experiment at CERN is focusing on a measurement of the deeply virtual Compton scattering. Several upgrades of the experimental setup have been performed in 2012, namely the construction of a long liquid hydrogen target and a surrounding recoil proton detector called CAMERA. Based on a …
-
Charge transport in polymer semiconductors
… is focused on the electrical characterization of polymer field effect transistors. Conventional method of characterizing organic polymeric semiconductors includes field-effect mobility measurement and optical time-of-flight measurement of drift mobility. In this dissertation we have introduced …
-
Predicting Surface Heat Flux and Temperature via a Pulse-Echo Acoustic Transducer for Inverse Heat Conduction Applications
… heat transfer situations rise where in-depth measurements must be used to predict a transient surface temperature or heat flux history. These occurrences are especially evident and necessary when a surface is exposed to a harsh thermal or chemical environment as the surface mounted sensor …
-
Ultrasonic Process Analytical Technology For The Control Of Injectables
… during pharmaceutical manufacturing requires timely process information without compromising qualified product-contact surfaces. This dissertation presents the development and experimental assessment of a non-invasive, clamp-on ultrasonic pulse–echo prototype for real-time estimation of sodium …
-
Optical Feshbach Resonances and Coherent Photoassociation in a Strontium BEC
The divalent electronic structure of alkaline-earth metal atoms such as strontium gives rise to metastable, excited triplet levels and narrow intercombination transitions. These have been exploited for optical clocks, powerful laser cooling techniques that are critical for achieving quantum …
-
Dynamic Structural Deflection Measurement with Range Cameras
… to construct bridges and other structures. Years of traffic overloading and insufficient maintenance have left civil infrastructure such as bridges in a poor state of repair. Therefore, the structures have to be strengthened. Many options for the reinforcement exist such as fibre-reinforced …
-
Measurement of 50Cr and 53Cr Neutron Capture Cross Sections for Nuclear Technology at CERN n_TOF and HiSPANoS
… energy has been recognized as crucial in terms of decreasing the CO2 emissions due to carbon sources while satisfying the increasing energy demands worldwide. The associated development towards a more efficient and safer nuclear energy requires nuclear data of high quality, serving criticality …
Page 1 of 2