Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Time-Resolved cathodoluminescence"”

  1. Time-resolved cathodoluminescence

    … the optical and structural properties. A new time resolved CL measurement system (TRCL) with spatial resolution of 50 nm and temporal resolution of 750 ps is developed. The design is based on sequential registration technique using gated intensified charge coupled device (ICCD) as time …

    nus Repository record for Time-resolved cathodoluminescence (opens in a new tab)

  2. Picosecond time resolved cathodoluminescence to study semiconductor materials and heterostructures

    … also needed to obtain local excited carrier lifetimes in a disordered material. Due to the need of such a characterization tool, we have developed an original picosecond time resolved cathodoluminescence (pTRCL) setup using an ultrafast pulsed electron gun mounted on a scanning electron …

    epfl Repository record for Picosecond time resolved cathodoluminescence to study semiconductor materials and heterostructures (opens in a new tab)

  3. Steady State and Time-Resolved Cathodoluminescence Analysis of III-Nitride Semiconductors

    Cathodoluminescence is a tool that is used to investigate optical emission from semiconductors. The technique operates by exciting the sample with a focused electron beam such that it becomes excited and emits photons which are then analysed. The technique can be operated with a continuous electron …

    cambridge Repository record for Steady State and Time-Resolved Cathodoluminescence Analysis of III-Nitride Semiconductors (opens in a new tab) Restricted access

  4. Hibridinių InGaN nanodarinių spektroskopija su erdvine skyra /

    … with quantum well structure using spatially time-resolved cathodoluminescence technique. Cathodoluminescence intensity spatial distributions, time-resolved spectroscopy measurements were observed and correlation between geometric parameters and cathodoluminescence properties explored. …

    vilnius Repository record for Hibridinių InGaN nanodarinių spektroskopija su erdvine skyra / (opens in a new tab)

  5. Nepolinių InGaN epitaksinių sluoksnių liuminescencijos ypatumai /

    … quantum well samples have been studied using time-resolved cathodoluminescence spectrometer.

    vilnius Repository record for Nepolinių InGaN epitaksinių sluoksnių liuminescencijos ypatumai / (opens in a new tab)

  6. Cathodoluminescence spectroscopy of organic-inorganic perovskites

    In this work, cathodoluminescence (CL) techniques was applied to hybrid perovskite materials to identify relationship between their crystallographic microstructure and emission properties. The cathodoluminescence spectra of MAPbI3 and CsPbBr3 were compared against conventional photoluminescence …

    nanyang Repository record for Cathodoluminescence spectroscopy of organic-inorganic perovskites (opens in a new tab)

  7. Multimicroscopy characterisation of AlGaN-based deep ultraviolet light emitting diodes

    … variations; and hyperspectral, spatially resolved cathodoluminescence together with time-resolved cathodoluminescence to characterize optoelectronic properties of state-of-art DUV LED samples andcharge carrier dynamics. Two series of three samples each, provided by researchers from Prof. …

    strathclyde Repository record for Multimicroscopy characterisation of AlGaN-based deep ultraviolet light emitting diodes (opens in a new tab)

  8. Defektų įtaka InGaN junginių liuminescencijos savybėms mikroskopiniame mastelyje /

    … Microscopy (SEM) as well as spatially- and time- resolved Cathodoluminescence (CL) Spectroscopy were employed to investigate the optical and structural properties of three sets of InGaN structures. These three sets contained MQWS and layers of: (i) various polarities; (ii) In content; (iii) …

    vilnius Repository record for Defektų įtaka InGaN junginių liuminescencijos savybėms mikroskopiniame mastelyje / (opens in a new tab)

  9. Cathodoluminescence of nitrogen vacancies in nanodiamonds and plasmonic nanostructures

    … in nanodiamond and plasmonic nanostructures by cathodoluminescence. In particular, I have demonstrated by time-resolved cathodoluminescence (TR-CL) and control of the emission of NV centres through tailoring the dielectric properties of the host medium (including dielectric, plasmonic). I have …

    soton Repository record for Cathodoluminescence of nitrogen vacancies in nanodiamonds and plasmonic nanostructures (opens in a new tab)

  10. Ultrafast spectroscopy of wide bandgap semiconductor nanostructures

    … and temporal resolutions of our original time resolved cathodoluminescence system. The movement mechanism was modeled by a hopping process of excitons. Our results pave the way to new experiments allowing to reveal the physics at play at the nanoscale in different materials. However, in …

    epfl Repository record for Ultrafast spectroscopy of wide bandgap semiconductor nanostructures (opens in a new tab)

  11. Ultrafast carrier dynamics in III-nitride nanostructures and LED quantum efficiency

    … around an isolated single dislocation, by using time-resolved cathodoluminescence (TR-CL). The exciton diffusion length and effective area of the dislocation are deduced by modeling the CL decays across the dislocation, which reveals the intrinsic properties of dislocations as NRCs. The type of …

    epfl Repository record for Ultrafast carrier dynamics in III-nitride nanostructures and LED quantum efficiency (opens in a new tab)

  12. Picosecond cathodoluminescence

    We have developed an original time resolved cathodoluminescence (TRCL) set-up with temporal performances similar to those of conventional time resolved optical techniques, keeping the capability to get structural information through the secondary electron mode of an electron microscope (SEM). This …

    epfl Repository record for Picosecond cathodoluminescence (opens in a new tab)

  13. Ultra-thin GaAs Photovoltaics for Space Applications

    … Talbot lithography (DTL) was used for the first time in a photovoltaic application to produce these nanostructures. DTL is a non-contact, wafer-scale interference lithography technique that produces periodic features with excellent uniformity over significant topography in a single exposure. A …

    cambridge Repository record for Ultra-thin GaAs Photovoltaics for Space Applications (opens in a new tab)

  14. Spectroscopie du temps de vie de la cathodoluminescence pour des LEDs efficaces à base de nitrure d'élément III

    … la lumière. Un outil particulièrement adapté, la cathodoluminescence (CL) utilise des électrons pour sonder la matière et permet d'atteindre une résolution spatiale de quelques dizaines de nanomètres. De plus, la grande énergie des électrons devant l'énergie de bande interdite des semiconducteurs …

    star-france Repository record for Spectroscopie du temps de vie de la cathodoluminescence pour des LEDs efficaces à base de nitrure d'élément III (opens in a new tab)

  15. Excitons dans le nitrure de bore hexagonal et ses homostructures en rotation : propriétés de volume, aux surfaces et aux interfaces

    … études ont été réalisées avec le dispositif de cathodoluminescence (CL) à résolution temporelle du GEMaC, qui permet un contrôle spatial et temporel de l'excitation adapté à l'étude de la dynamique excitonique. Les expériences ont été effectuées sur des monocristaux de hBN de différentes …

    star-france Repository record for Excitons dans le nitrure de bore hexagonal et ses homostructures en rotation : propriétés de volume, aux surfaces et aux interfaces (opens in a new tab)