Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 77 for “"Time-gated"”.

  1. Time-Gated Fourier-Domain Optical Coherence Tomography

    … resolutions with fast acquisition times. This imaging modality uses the interference between light backscattered from a sample and light that has traversed a known reference path delay to determine the scattering profile over penetration depths of up to several millimetres in …

    queens Repository record for Time-Gated Fourier-Domain Optical Coherence Tomography (opens in a new tab)

  2. Design of Time-Gated CMOS SPADs Towards High-Performance Imagers

    … positron emission tomography, fluorescence lifetime imaging, light detection and ranging, and more. SPAD fabrication has shifted recently towards custom technologies, 3D stacked designs, and post-processing steps (micro-lenses) to improve performance at the expense of increased cost and …

    mcmaster Repository record for Design of Time-Gated CMOS SPADs Towards High-Performance Imagers (opens in a new tab)

  3. SNM neutron detection using a time-gated synthetic aperture hybrid approach

    … as a large area system enables one to apply time gating the source-detector response to maximize signal to noise responses from a passing source with minimal background; multiple units may be positioned as a collective synthetic aperture detector array to be used as a way of performing real …

    gatech Repository record for SNM neutron detection using a time-gated synthetic aperture hybrid approach (opens in a new tab)

  4. Three Dimensional Localization with Time-Gated Photon Counting and Maximum Likelihood Analysis

    … objective. Maximum likelihood analysis of the time-gated fluorescence photons then provides sub-diffraction localization of single emitters. Samples of Rhodamine B, fluorescent latex beads, and nanospheres of gold are evaluated to see if they provide adequate signal-to-noise with time-gated …

    ut-knoxville Repository record for Three Dimensional Localization with Time-Gated Photon Counting and Maximum Likelihood Analysis (opens in a new tab)

  5. Ultrafast-time-gated ballistic-photon imaging and shadowgraphy in optically dense rocket sprays

    … in dense sprays by employing an ultrafast time gate to discriminate against diffuse light. The goal of this work is to improve on the existing imaging system and investigate the breakup mechanisms of the liquid core immediately following injection. By reducing the contribution from photons …

    iastate Repository record for Ultrafast-time-gated ballistic-photon imaging and shadowgraphy in optically dense rocket sprays (opens in a new tab)

  6. A Time-Gated Fluorescence Instrument and Its Applications Using Mn-Doped I(II)-III-VI Nanocrystal Probes

    … this work, two versions of a low-cost, portable, time-gated fluorescence intensity measurement instrument were developed with the primary aim of utilizing Mn-doped I(II)-III-VI nanocrystals (Mn:AgZnInS/ZnS and Mn:CuZnInS/ZnS core/shell) as long-lifetime fluorescent probes for sensing applications. …

    unr Repository record for A Time-Gated Fluorescence Instrument and Its Applications Using Mn-Doped I(II)-III-VI Nanocrystal Probes (opens in a new tab)

  7. Design of a Time-to-Digital Converter and Multi-Time-Gated SPAD Arrays Towards Biomedical Imaging Applications

    … sensing systems formed from the integration of time-to-digital converters (TDCs) with arrays of highly sensitive photodetectors known as SPADs. TDCs are high-performance mixed-signal circuits capable of timestamping events with picosecond level resolution. The digital operation mechanisms of …

    mcmaster Repository record for Design of a Time-to-Digital Converter and Multi-Time-Gated SPAD Arrays Towards Biomedical Imaging Applications (opens in a new tab)

  8. Miniaturization of Time-Gated Raman Spectrometer with a Concave Grating and a CMOS Single Photon Avalanche Diode

    … suppression, the SPAD is operated in the time-gated (TG) mode. The TG-SPAD is implemented in a 130nm standard CMOS technology. Fast gating, generation and readout circuits are designed to gate the SPAD at frequencies up to 100MHz, with a short gate window of 3.5ns. Negligible afterpulsing …

    mcmaster Repository record for Miniaturization of Time-Gated Raman Spectrometer with a Concave Grating and a CMOS Single Photon Avalanche Diode (opens in a new tab)

  9. Improvements to Optical Diagnostics of Thermal Barrier Coatings: Contaminant Identification during Laser Cleaning and Time Gated Photoluminescence Piezospectroscopy

    … has been previously used to assess remaining lifetime of TBCs, can suffer from fluorescence interference due to dopants in the coating composition. Unlike that of CMAS obstruction, which can be cleaned via LIBS, the source of interference within the coating could not be physically removed. A …

    uconn-diss Repository record for Improvements to Optical Diagnostics of Thermal Barrier Coatings: Contaminant Identification during Laser Cleaning and Time Gated Photoluminescence Piezospectroscopy (opens in a new tab)

  10. An Experimental Study of Tungsten Wire-Array Z-Pinch Plasmas Using Time-Gated Point-Projection X-Ray Imaging

    … (peak) current pulse with a zero-to-peak rise-time of approximately 100ns. The tungsten (W) wires used in these experiments had initial diameters ranging from 5.1 to 25um. For most experiments the array diameter was 8mm or 12mm and the array height was 8mm. Wire-array Z-pinch plasmas are …

    cornell Repository record for An Experimental Study of Tungsten Wire-Array Z-Pinch Plasmas Using Time-Gated Point-Projection X-Ray Imaging (opens in a new tab)

  11. Development of spectrometric field analytical systems

    … mA) was fabricated. Using this LED, a compact gated Terbium dipicolinate photoluminescence measurement system capable of detecting 0.4 nM DPA is built. DPA can be used as a selective marker for detecting bacterial spores, notably that of anthrax. The basic principle of using a highly …

    ttu Repository record for Development of spectrometric field analytical systems (opens in a new tab)

  12. A Characterization of Pulsatile Flow by Positron Emission Particle Tracking

    … Trajectories are divided into 20 equally spaced time gated frames in each pulse cycle. A three-dimensional velocity field is generated at each phase of the pulse cycle by integrating time gated data from several hundred pulse cycles. The average location uncertainty in the M-PEPT measurement is …

    ut-knoxville Repository record for A Characterization of Pulsatile Flow by Positron Emission Particle Tracking (opens in a new tab)

  13. Time-Controlled CMOS Single-Photon Avalanche Diodes Receivers Towards Optical Wireless Communication Applications

    … interference (ISI) effect caused by dead time is an important drawback that limits performance. In this thesis, we propose two novel SPAD operation receivers to reduce the ISI effect in SPAD-based OWC. To validate the feasibility of these two modes, we design a free-running SPAD front-end …

    mcmaster Repository record for Time-Controlled CMOS Single-Photon Avalanche Diodes Receivers Towards Optical Wireless Communication Applications (opens in a new tab)

  14. Radiative properties of Z-pinch and laser produced plasmas from mid-atomic-number materials

    … and usefulness of spectroscopy, particularly time-gated x-ray spectroscopy. For example, modeling of time-gated L-shell spectra captured from the precursor column of low-wire-number copper cylindrical wire arrays reveals electron temperatures ~400 eV, which is significantly higher than any …

    unr Repository record for Radiative properties of Z-pinch and laser produced plasmas from mid-atomic-number materials (opens in a new tab)

  15. Room Temperature Phosphorescence (RTP): Experimental And Theoretical Studies on Boron-Containing Materials

    … in security printing, OLEDs, optical storage, time-gated biological imaging and oxygen sensors. We report the first persistent RTP with lifetimes up to 0.5 s from simple triarylboranes which have no lone pairs. We also have prepared 3 isomeric (o, m, …

    wurz-thes Repository record for Room Temperature Phosphorescence (RTP): Experimental And Theoretical Studies on Boron-Containing Materials (opens in a new tab)

  16. Radio-Frequency Passive Wireless Sensing for Agricultural Applications

    … a new interrogation mechanism is explored. A time-gated transceiver for backscatter interrogation is assembled. The importance of high quality factor sensor nodes and the potential of microacoustic resonators to obtain high quality factor is established. Using the time-gated transceiver, a …

    penn Repository record for Radio-Frequency Passive Wireless Sensing for Agricultural Applications (opens in a new tab)

  17. Methods for Efficient Computation of Neutron Multiplicity Distributions and SNM Sample Characterization

    … neutron count distributions in a fixed detector time-gate. NMC limitations associated with finite-size and neutron phase effects are also addressed by extending the BME model to account for time-gated neutron count distributions in full phase space with implementation of the first four moment in …

    unm Repository record for Methods for Efficient Computation of Neutron Multiplicity Distributions and SNM Sample Characterization (opens in a new tab)

Page 1 of 4