Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Time-varying elastance"”
-
Device for automating in vitro characterization of lymphatic vessel function
… investigators developed the concept of time-varying elastance. We evaluated the applicability of this concept to lymphangions by analyzing preliminary data obtained from the bovine mesenteric vessels. We found that there were some limitations to the applicability of this concept to …
-
Matematické modelování srdeční energetiky při aortální stenóze
… kardiovaskulárního systému, který integruje time-varying elastance model, 3 a 2 prvkový Windkessel model pro systémovou a plicní arteriální a venózní cirkulaci a „lumped-parameter“ model koronární cirkulace za účelem analýzy celkové energetické bilance srdce při závažné aortální stenóze. …
-
Effects of a stiffened arterial tree on ventricular-arterial coupling in healthy and diseased hearts
… the issue of the universality of the normalized time-varying elastance curve. It is demonstrated that the waveform of the normalized time-varying elastance curve (En(tn)) is qualitatively comparable between the control and MI hearts, however, when En(tn) is compared quantitatively between the two …
-
A computational approach to study the effect of multiple lymphangion coordination on lymph flow
… described by the classic description of time-varying elastance. When pumping up a pressure gradient, as in normal conditions, or when pumping down a pressure gradient, as in some cases of edema, we found that flow was optimized when the lymphangions in the vessel were pumping with a very …
-
Untersuchung des Einflusses der cerebralen Autoregulation auf die Messung der kardialen Kontraktilität mittels Fluß-Flächen-Beziehung
Fragestellung: Die time varying elastance, der Gold-Standart zur Bestimmung der myokardialen Kontraktilität, kann entweder mittels Druck-Volumen Kurven, die mit einem Conductance-Katheter gemessen wurden, oder über eine, mittels Ultraschalltechnik generierte, Fluß-Flächen-Beziehung bestimmt werden. …
-
Structural and functional characterization of a lymphatic system using computational and experimental approaches
… network structure, we used an approximation of time-varying elastance model. We found there is an optimal length for the lymphangion when it produces maximal flow. To develop a fractal network model, we determined the ratio of radius and ratio of length of lymphangion at a confluence. Using …
-
Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices
… Freedom (portable), Driver operating against varying loading conditions. Our results describe the hemodynamic envelope of the TAH. Uniquely, the TAH was found not to operate with time-varying elastance, to be insensitive to variations in afterload up to at least 135 mmHg mean aortic pressure, …
-
Studies in right ventricular function : employing the conductance catheter method for ventricular volume determination
… systole and diastole and proposed the model of "time-varying elastance". One success of this approach has been the development of contractile indices that are generally independent of loading conditions. These indices, Emax, preload recruitable stroke work index and dP/dtmax-end-diastolic volume …
-
Assessment of Cardiac Function by Acoustic Radiation Force (ARF) Based Methods of Ultrasound Elastography
… had the potential to be a direct measure of the time-varying elastance measured during the cardiac cycle using pressure-volume measurements. The question arose as to whether these ARF based measurements of dynamic stiffness could be used for cardiac functional assessments during systole and …
-
Towards patient-specific modelling as a pre-operative planning strategy and follow up assessment for the treatment of advanced heart failure with rotary blood pumps
… left ventricular assist device (LVAD) requires a timely discussion at a Multi-Disciplinary Team Meeting (MDT). Clinical-decision making is based according to the needs of the patient and must be processed without delays. Nevertheless, thrombus formation remains a feared complication which affects …
-
Exploitation conjointe d'un modèle biomécanique patient-spécifique de coeur et vaisseaux et de données mesurées au bloc opératoire pour augmenter le monitorage hémodynamique des patients sous anesthésie générale
L'évaluation hémodynamique des patients sous anesthésie générale est une tache complexe pour les médecins anesthésistes et/ou réanimateurs. En effet, les techniques de monitorage sont imparfaites, imprécises et/ou invasives, et le choix de la technique de monitorage doit prendre en compte la …