Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"Timepix"”

  1. Viability of Determining Ion Charge and Velocity Utilizing a Single Silicon Timepix Detector

    The emergence of the Timepix technology, a class of hybrid pixel readout Application-Specific Integrated Circuits (ASIC), has provided an opportunity for the evolution of small, low-power, active radiation detectors which have unprecedented capability. The application of this technology to …

    houston Repository record for Viability of Determining Ion Charge and Velocity Utilizing a Single Silicon Timepix Detector (opens in a new tab)

  2. Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy

    The Timepix detector developed by CERN is a novel and sophisticated particle detector. It consists of a semiconductor layer divided into an array of pixels. This array of pixels is bumpbonded to an electronics integrated layer (i.e. the readout chip). Timepix can be used for a wide range of …

    adelaide Repository record for Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy (opens in a new tab)

  3. A PATTERN RECOGNITION APPROACH TO LEARNING TRACKS OF HEAVY-ION PARTICLES IN TIMEPIX DETECTORS

    … The work reported here is based on the Timepix chip, which when coupled with an Si sensor, can function as an active nuclear emulsion, allowing the visualization of the individual tracks created as the different incident particles traverse the detector. The Timepix chip provides the …

    houston Repository record for A PATTERN RECOGNITION APPROACH TO LEARNING TRACKS OF HEAVY-ION PARTICLES IN TIMEPIX DETECTORS (opens in a new tab)

  4. Versatile low-energy electron source at the PHIL accelerator to characterise Micromegas with integrated Timepix CMOS readout and study dE/dx for low energy electrons

    Dans le cadre de cette thèse, la conception, la construction et la mise en service de la plateforme de test LEETECH ont été réalisées. La performance de LEETECH, y compris le mode de fonctionnement à faible multiplicité a été démontrée. En fournissant des paquets d’électrons avec une énergie …

    star-france Repository record for Versatile low-energy electron source at the PHIL accelerator to characterise Micromegas with integrated Timepix CMOS readout and study dE/dx for low energy electrons (opens in a new tab)

  5. Simulation and validation of charge carrier drift in pixelated microstructured semiconductor neutron detectors

    … Neutron Detector (MSNDs) bump bonded onto a Timepix pixelated readout chip. The device serves as a combined neutron and photon imager with a 256x256 pixel array, using per-pixel time-over-threshold (ToT) energy deposition. The X-MSND design has produced thermal neutron detection efficiency of …

    ksu Repository record for Simulation and validation of charge carrier drift in pixelated microstructured semiconductor neutron detectors (opens in a new tab)

  6. CdTe/CdZnTe pixellated radiation detector

    … and imaging performance of pixellated CdTe Timepix detector. Two pitches of pixel have been studied namely, 110 µm pitch and 55 µm pitch. The work on characterisations has been performed with polychromatic and monoenergetic beams of X-rays. In both the Counting mode and ToT (Time over …

    glasgow Repository record for CdTe/CdZnTe pixellated radiation detector (opens in a new tab)

  7. Development of an energy filtering direct electron detector for diffraction studies in the SEM

    … hybrid pixel detector, \Timepix" for electron backscatter diffraction (EBSD), a technique which allows the acquisition of precise crystallographic information from the surface of a sample, such as crystallographic orientation, phase and strain. EBSD results from nitride …

    strathclyde Repository record for Development of an energy filtering direct electron detector for diffraction studies in the SEM (opens in a new tab)

  8. A Novel Approach to Ion Spectroscopy of Therapeutic Ion Beams Using a Pixelated Semiconductor Detector

    … semiconductor detector is presented. The used Timepix detector, originally designed for photon beam imaging, offers a high spatial resolution enabling the detection of single particles. At first, an extensive characterization of the detector response to therapeutic ion beams was performed. The …

    heid-diss Repository record for A Novel Approach to Ion Spectroscopy of Therapeutic Ion Beams Using a Pixelated Semiconductor Detector (opens in a new tab)

  9. Simulation of Radiation Source Localization through Circle Approach and 3-D Visualization of Unknown Environment Using UGV Equipped with 3-D Lidar Based on Rotational 2-D Lidar

    … employing Ray-Tracing algorithms as well as Timepix hybrid pixel detector that is exceedingly small, powerful, and capable of measuring has been recently contributed to literature for the first time so that researchers are able to simulate these models and test methods under different …

    tamu Repository record for Simulation of Radiation Source Localization through Circle Approach and 3-D Visualization of Unknown Environment Using UGV Equipped with 3-D Lidar Based on Rotational 2-D Lidar (opens in a new tab)

  10. Characterization of Advanced Detector Technologies for Neutron Science Applications

    … of several detector technologies, enabled by the timepix3 ASIC, designed to enhance the scientific capabilities of neutron scattering facilities, particularly those at HFIR and SNS at ORNL. In part one, suitability of the novel Lithium-containing semiconductor Lithium Indium Phosphor Selenide …

    utk-theses Repository record for Characterization of Advanced Detector Technologies for Neutron Science Applications (opens in a new tab)

  11. Neutron Detection and Imaging Development of Lithium Indium Diselenide for Applications in Solid-State Devices

    … pitch pattern, derived from the 256×256 channel Timepix. The Timepix coupled LISe imager (LISePix) completed the groundwork for the detector as a high-resolution neutron imager, surpassing the design goal with a published spatial resolution limit of 34 μm (full width at half maximum (FWHM) of 111 …

    utk-theses Repository record for Neutron Detection and Imaging Development of Lithium Indium Diselenide for Applications in Solid-State Devices (opens in a new tab)

  12. Développement d'un imageur neutron portable

    … se reposant sur un masque codé et un détecteur Timepix modifié par une couche de paraffine. Le dernier axe concerne le déploiement et la caractérisation expérimentale de ce prototype.

    star-france Repository record for Développement d'un imageur neutron portable (opens in a new tab)

  13. Development of 3D Silicon radiation detectors for neutrons and high energy charged particles

    … read-out chips (e.g., those from the Medipix/Timepix family) is an important goal that was achieved in this thesis. In this thesis the entire workflow will be described in detail, covering the design, simulations, fabrication and characterization of 3D neutron detectors for imaging produced at …

    trento Repository record for Development of 3D Silicon radiation detectors for neutrons and high energy charged particles (opens in a new tab)

  14. Detectors developments for the UA9 experiment at the CERN SPS

    … Cherenkov (CpFM) et les détecteurs à pixel (Timepix). Depuis 2015, le CpFM (détecteur de Cherenkov pour la mesure du flux de protons) a été souvent modifié afin d'améliorer la précision pour le comptage des particules. La plage de fonctionnement du dispositif varie de 1 à 1000 particules par …

    star-france Repository record for Detectors developments for the UA9 experiment at the CERN SPS (opens in a new tab)

  15. On the spectrometry of laser-accelerated particle bunches and laser-driven proton radiography

    … the sensor chip of a hybrid pixel detector Timepix was irradiated edge-on with protons in the energy interval between 17 and 20 MeV. Spatial information along one axis perpendicular to the proton beam direction was obtained due to the pixelation of the detector. Although this spectrometric …

    lmu-germany Repository record for On the spectrometry of laser-accelerated particle bunches and laser-driven proton radiography (opens in a new tab)

  16. Ion Spectroscopy for improvement of the Physical Beam Model for Therapy Planning in Ion Beam Therapy

    … of versatile pixelated semiconductor detectors (Timepix). This method is based on tracking of single particles and pattern recognition of their signals in the detectors. Measurements were performed at the HIT facility. The mixed radiation field arising from 430 MeV/u carbon ion beams and 221 …

    heid-diss Repository record for Ion Spectroscopy for improvement of the Physical Beam Model for Therapy Planning in Ion Beam Therapy (opens in a new tab)

  17. Development and Characterization of Lithium Indium Diselenide for Neutron Detection and Imaging Applications

    … coupling a LISe crystal to a 256 x 256 channel Timepix Application Specific Integrated Circuit to maximize spatial resolution. The fast neutron spatial resolution for 9MeV [electron-Volts] neutrons was investigated via a knife edge experiment. The measured efficiency was in agreement with the …

    utk-theses Repository record for Development and Characterization of Lithium Indium Diselenide for Neutron Detection and Imaging Applications (opens in a new tab)

  18. Crystals for indirect and direct detectors employed in X-ray imaging applications

    … x 1010 ph/mm2/s. Results showed that the CdTe Timepix detectors should not be exposed at photon fluxes higher than 1.6 x 108 ph/mm2/s, that correspond to the dead time limit. As soon as the dead time threshold is approached the occurrence of pile up effects is observed, which reduce the …

    freiburg-diss Repository record for Crystals for indirect and direct detectors employed in X-ray imaging applications (opens in a new tab)

  19. Evaluation of radiation field properties with pixel semiconductor detectors operating in particle tracking mode

    … the detector network are presented including new Timepix readout chip, multilayer detector concept and possibility of usage of the CdTe sensor material. <br>The results presented in this thesis have proven to be an important feedback for ATLAS community and will possibly allow the calculation of …

    freiburg-diss Repository record for Evaluation of radiation field properties with pixel semiconductor detectors operating in particle tracking mode (opens in a new tab)

  20. Application and development of advanced Lorentz microscopy techniques for the study of magnetic nanostructures

    … detector on the TEM in the form of a Medipix/Timepix chip capable of microsecond exposure times without adding noise. Running this detector in integral mode and allowing for practical limitations such as experiment time and aperture stability, the resultant streak images were taken in Fresnel, …

    glasgow Repository record for Application and development of advanced Lorentz microscopy techniques for the study of magnetic nanostructures (opens in a new tab)

Page 1 of 2