Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 48 for “"Tissue Strain"”.

  1. Effects of Striker Compliance on Dynamic Response and Brain Tissue Strain for Helmeted Ice Hockey Impacts

    … and its influence on dynamic response and brain tissue strain was investigated in this study. In hockey, players can experience a broad range of striking/surface compliance during a head impact, from the stiff ice surface to highly compliant player collisions. An increase in striking compliance …

    ottawa-retro Repository record for Effects of Striker Compliance on Dynamic Response and Brain Tissue Strain for Helmeted Ice Hockey Impacts (opens in a new tab)

  2. The Use of Decoupling Structures in Helmet Liners to Reduce Maximum Principal Brain Tissue Strain for Head Impacts

    … speculate rotation of the head leads to shear strain on the brain tissue, which may be the underlying mechanism of injury leading to concussive type injuries [Gennarelli 1971, Ommaya 1974, Gennarelli 1982, Prange 2002, Gilcrhist 2003, Aare 2003, Zhang 2004, Takhounts 2008, Greenwald 2008, …

    ottawa-retro Repository record for The Use of Decoupling Structures in Helmet Liners to Reduce Maximum Principal Brain Tissue Strain for Head Impacts (opens in a new tab)

  3. Investigating the Relationship Between Kinematic-Based Brain Injury Metrics and Brain Tissue Strain for a Football Helmet Test Standard

    … with concussive injury. Maximum principal strain (MPS) is widely used as a strain-based predictor of brain injury; however, computational cost limits its application in helmet certification. As a practical alternative, helmet standards rely on kinematic-based brain injury metrics derived …

    ottawa-retro Repository record for Investigating the Relationship Between Kinematic-Based Brain Injury Metrics and Brain Tissue Strain for a Football Helmet Test Standard (opens in a new tab)

  4. Mechanical Characterization of Vertically Aligned Carbon Nanotube Forest Microelectrodes for Neural Interfacing

    … which remains active in response to the brain tissue strain caused by implanted probes during brain micromotion. Designing probes with softer materials can reduce the chronic FBR and improve device lifetime. A high-aspect ratio CNT MEA could provide several advantages as an intracortical MEA …

    byu Repository record for Mechanical Characterization of Vertically Aligned Carbon Nanotube Forest Microelectrodes for Neural Interfacing (opens in a new tab) Download PDF for Mechanical Characterization of Vertically Aligned Carbon Nanotube Forest Microelectrodes for Neural Interfacing (opens in a new tab)

  5. Mathematically modeling the mechanical constants of thoracolumbar fascia under compression, in vivo

    … have made it possible to move towards measuring tissue strain. Since this is an in vivo method, mechanical data of tissues in their natural environment allows a more accurate representation of tissue strain. However, many different methods of analyzing ultrasound data have been proposed. In this …

    njit Repository record for Mathematically modeling the mechanical constants of thoracolumbar fascia under compression, in vivo (opens in a new tab)

  6. Does a Regular Menstrual Tampon or an Intravaginal Pessary Mitigate Urine Leakage While Running Among Females Who Experience Exercise-Induced Urinary Incontinence?

    … during the run, exercise-induced pelvic floor tissue strain assessed via transperineal ultrasound imaging, and user self-reported experience. Both devices significantly reduced EI-UI Severity Index scores compared to no intervention, with the pessary offering significantly greater symptom …

    ottawa-retro Repository record for Does a Regular Menstrual Tampon or an Intravaginal Pessary Mitigate Urine Leakage While Running Among Females Who Experience Exercise-Induced Urinary Incontinence? (opens in a new tab)

  7. Biomechanics and dynamics of turning

    … prosthetic socket to predict the differences in tissue strain between walking straight and turning, both with and without a prosthetic rotation adaptor. There are differences in the absolute amounts of tissue strain and its rate of increase between walking straight and turning. The inclusion of a …

    washington Repository record for Biomechanics and dynamics of turning (opens in a new tab)

  8. Impact Characteristics Describing Concussive Injury in Youth

    … in the dynamic response of the head and brain tissue deformation characteristics between children and adolescents for falls in comparison to adult data which have resulted in concussive injuries. Patient data was collected from emergency room hospitals across Canada. After exclusion criterion …

    ottawa-retro Repository record for Impact Characteristics Describing Concussive Injury in Youth (opens in a new tab)

  9. Comparing Equestrian Helmets with and without Rotational Technology Using an Equestrian Concussive Specific Helmet Test Protocol

    … These accelerations create injurious brain tissue strain. While both linear and rotational accelerations occur during head impacts, the rotational components of acceleration are closely linked to brain tissue strain. To reduce brain strain, helmet technologies have been developed with the …

    ottawa-retro Repository record for Comparing Equestrian Helmets with and without Rotational Technology Using an Equestrian Concussive Specific Helmet Test Protocol (opens in a new tab)

  10. Recapitulating Native Tissue Biaxial Mechanical Properties in Tissue-Engineered Pulmonary Valves to Improve Their Hemodynamic Function and Tissue Homeostasis

    Current tissue-engineered heart valves undergo adverse tissue remodelling in vivo that leads to leaflet shortening and regurgitation. This adverse remodelling is in part due to non-physiological tissue strain response to hemodynamic pressure in diastole. Abnormal strains experienced by the valve …

    toronto-retro Repository record for Recapitulating Native Tissue Biaxial Mechanical Properties in Tissue-Engineered Pulmonary Valves to Improve Their Hemodynamic Function and Tissue Homeostasis (opens in a new tab)

  11. Analysis of 3D Strain in the Human Medial Meniscus and Comparison to 3D Strain in Meniscal Allograft Transplants

    A method of measuring 3D strain in-vitro is presented. Regional 3D meniscal strain has not been studied in a large number of human knees under simulated physiological loading. Strain is calculated by tracking markers implanted within the meniscal tissue using computed tomography imaging under …

    guelph Repository record for Analysis of 3D Strain in the Human Medial Meniscus and Comparison to 3D Strain in Meniscal Allograft Transplants (opens in a new tab)

  12. The Role of the Bronchi in Strain-induced Pulmonary Injury

    … the dynamic response of ex-vivo porcine lung tissue during a direct, blunt impact. A high-speed X-ray system captured the lung deformation and local tissue strain fields. It was found that the motion of the bronchi, with higher stiffness and density than the surrounding parenchyma, contributed …

    carleton Repository record for The Role of the Bronchi in Strain-induced Pulmonary Injury (opens in a new tab)

  13. Developing a framework for an adaptive transtibial prosthetic socket using FEA-based tissue injury risk estimation and generalised predictive control

    … fit. Poorly fitting sockets cause pain, limb tissue injuries, limited device usage, and potential rejection. Contact stresses at the socket-limb interface and strain of underlying soft tissues greatly determine user comfort and the risk of residuum tissue injury. Adjustable socket technologies …

    soton Download PDF for Developing a framework for an adaptive transtibial prosthetic socket using FEA-based tissue injury risk estimation and generalised predictive control (opens in a new tab)

  14. Spatial Regulation of Bone Formation in Functional Adaptation of Cancellous Bone

    … density. Forces on whole bones cause non-uniform tissue strains throughout bone’s internal structure. Bone formation is hypothesized to occur at locations of greatest tissue strains. In this dissertation, I examined the relationship between locations of bone formation and local tissue strains in …

    cornell Repository record for Spatial Regulation of Bone Formation in Functional Adaptation of Cancellous Bone (opens in a new tab)

  15. FRAMEWORK FOR DIGITAL TWIN SIMULATION OF A MAGNETICALLY ACTUATED PARALLEL ROBOT FOR ADAPTIVE TISSUE STRETCHING

    … stimulation of engineered skeletal muscle tissue. The physical setup consists of a dual-rod platform, where an external magnetic field actuates a flexible rod embedded with a permanent magnet, and a second rod remains fixed. Engineered muscle tissue is anchored between the two rod ends, …

    jhu Repository record for FRAMEWORK FOR DIGITAL TWIN SIMULATION OF A MAGNETICALLY ACTUATED PARALLEL ROBOT FOR ADAPTIVE TISSUE STRETCHING (opens in a new tab) Embargoed until 2027-08-01

  16. Mechanical Loading for Modifying Tissue Water Content and Optical Properties

    The majority of the physical properties of tissue depend directly on the interstitial or intracellular concentration of water within the epidermal and dermal layers. The relationship between skin constituent concentrations, such as water and protein, and the mechanical and optical properties of …

    vt Repository record for Mechanical Loading for Modifying Tissue Water Content and Optical Properties (opens in a new tab)

  17. Kompressions-Sonoelastographie zur Beurteilung der chronischen Transplantatschädigung bei nierentransplantierten Patienten

    Beantwortet werden soll die Frage, ob die TSI (Tissue Strain Imaging) Sono- elastographietechnik sowie die Realtime-Elastographie einen diagnostischen Beitrag zur Evaluation der chronischen Nieren-Transplantatschädigung leisten kann. Dafür wurden in einer prospektiven Studie die Elastographiedaten …

    fu-berlin Repository record for Kompressions-Sonoelastographie zur Beurteilung der chronischen Transplantatschädigung bei nierentransplantierten Patienten (opens in a new tab)

  18. An Enhanced Method for Full-Inversion-Based Ultrasound Elastography of The Liver

    … associated with biological changes that lead to tissue stiffening. An effective imaging technique that can be used for liver cancer detection through visualizing tissue stiffness is ultrasound elastography. In this thesis, we show the effectiveness of an enhanced method of tissue motion tracking …

    york Repository record for An Enhanced Method for Full-Inversion-Based Ultrasound Elastography of The Liver (opens in a new tab)

  19. A Comparison Between Two Oblique Test Protocols for Cycling Helmets

    … Rotational acceleration stimulates brain tissue strain resulting in mild to severe brain injuries. Current bicycle helmet standards test for linear acceleration, but not for rotational acceleration. The proposed standard (EN13087-11) by the European Committee for Standardization (CEN) and …

    ottawa-retro Repository record for A Comparison Between Two Oblique Test Protocols for Cycling Helmets (opens in a new tab)

Page 1 of 3