Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"Tissue Tracking"”.
-
Tissue Tracking and Motion Compensation for Robotic Surgery
The ability to negate tissue motion without complex physical constraints would greatly benefit beating heart surgery, procedures where respiration causes tissue movement, and in the case of physically unstable operating environments such as a battlefield, moving vehicle, or space station. Using a …
-
Towards automating cine DENSE MRI image analysis : segmentation, tissue tracking and strain computation
Over the past two decades, magnetic resonance imaging (MRI) has developed into a powerful imaging tool for the heart. Imaging cardiac morphology is now commonplace in clinical practice, and a plethora of quantitative techniques have also arisen on the research front. Myocardial tagging is an …
-
Developing surgical navigation tools for minimally invasive surgery using ultrasound, structured light, tissue tracking and augmented reality.
… more accurate and reduce the amount of healthy tissue they excise during operations. The ultrasound calibration technique improved ultrasound-based pinhead point reconstruction accuracy from 3.1mm to 1.3mm. The Pico Lantern and the PARIS were developed to improve surface reconstruction and to …
-
Assessment of long axis ventricular function in the fetal heart based on 2D grey scale image processing with a tissue tracking algorithm
Tissue-Tracking Echocardiography is a new method for in vivo quantitative assessment of the myocardial contraction and relaxation on the basis of grey scale 2D digital loops. This method is based on the estimation of motion and deformation parameters due to tissue compression and expansion and …
-
Real-time tracking of surgical tissue
This thesis addresses the problem of tracking surgical tissue using camera data in robotically assisted minimally invasive surgery. Millions of robotically assisted surgeries are performed yearly. These surgeries are performed by a surgeon who uses a teleoperation console. This console gives the …
-
Gewebedoppler-Echokardiografie und N-terminales Brain Natriuretic Peptide (NT- proBNP) bei der chronischen Herzinsuffizienz mit normaler und mit reduzierter linksventrikulärer Pumpfunktion
… (TVI, longitudinal Strain, Tissue Tracking) bei der Herzinsuffizienz mit normaler (HFNEF) und mit reduzierter (HFREF) linksventrikulärer Pumpfunktion zu untersuchen. Methodik: Wir schlossen in diese Studie ambulante und stationär betreute, klinisch stabile Patienten, die sich …
-
Filter Design and Consistency Evaluation for 3D Tongue Motion Estimation using Harmonic Phase Analysis Method
… used to produce harmonic phase images used for tissue tracking, influences the estimation accuracy. For this work, we evaluated different filtering approaches, and propose a novel high-pass filter for volumes tagged in individual directions. Testing was done using an open benchmarking dataset …
-
Cardiac resynchronization therapy in narrow QRS heart failure patients
… gender to wide QRS patients for a multi-plane tissue tracking and speckle-tracking echocardiographic analysis. Results: Narrow QRS patients were younger and had less radial dyssynchrony at baseline. Increases in EF of 3.2 ± 9% and 6.8 ± 9% (p<0.05) were seen in narrow and wide QRS patients, …
-
Deep learning-based 3d optical image reconstruction and surgical guidance
… reducing the risk of damage to surrounding tissues and improving patient outcomes. This dissertation consists of developing two different 3D intraoperative imaging modalities. The first is a high-speed volumetric(3D) optical coherence tomography system. OCT allows high-resolution volumetric …
-
Neue Biomarker zur Differenzierung von systolischer und diastolischer Herzinsuffizienz
… die Parameter longitudinaler septaler Strain, Tissue tracking sowie septal, rechts- und linkslateral bestimmte Gewebedopplergeschwindigkeiten (TDI). Als Biomarker wurden MR-proANP, MR-proADM, Copeptin und Endothelin evaluiert (Assays: Thermofischer AG). Statistische Untersuchungen wurden mit …
-
Ultrasound registration and tracking for robot-assisted laproscopic surgery
… between the ultrasound image and the underlying tissues, since tissues will move and deform from patient breathing and heartbeat, and from surgical instrument interaction with tissues. In order to overcome this, the underlying tissue should be tracked, and previously acquired ultrasound images …
-
Using tissue doppler imaging during exercise to assess ventricular function and wall motion in childhood survivors of acute lymphoblastic leukemia
… dysfunction, indicative of cardiotoxicity. Tissue Doppler Imaging (TDI) is a new echocardiographic technique that can be incorporated into current stress echocardiography protocols to potentially enhance our ability to detect early changes in cardiac function in ALL patients treated with …
-
Cardiac-coronary interaction in diastolic dysfunction
… diastolic strain and strain rate determined by tissue tracking of cardiac magnetic resonance imaging to invasive indices of diastolic function. Furthermore, using the aortic pressure trace, the validity of a modified Windkessel RC model to estimate changes in stroke volume will be assessed using …
-
Cardiovascular Magnetic Resonance Imaging in Cardiometabolic Disease
… elevations in Native T1, a surrogate marker of tissue fibrosis. Strain analysis, by novel CMR tissue tracking analysis, revealed a hyper-contractile state, likely representing a combined contribution of elevated systolic blood pressure with compensatory myocyte hypertrophy. Obese subjects were …
-
Zweidimensionales Speckle Tracking im Vergleich zu dopplerbasierten Ultraschallmethoden zur Bestimmung der myokardialen Funktionsparameter Tissue Velocity, Strain Rate und Strain
… können die myokardialen Funktionsparameter Tissue Velocity, Strain Rate und Strain auf verschiedene Arten berechnet werden. Es besteht die Möglichkeit, die Parameter mittels Gewebedoppler zu analysieren. Neue Techniken sind die Methode des Speckle Tracking und Kombinationen beider Methoden. …
-
Myocardial strain measured in survivors of acute ST-elevation myocardial infarction: implementation and prognostic significance of novel magnetic resonance imaging methods
… (DENSE) and cine derived methods such as feature-tracking. Whilst cine-derived strain is more appealing for imaging in real-world practice, there are concerns on accuracy, especially on a myocardial segmental level. Deformation-tracking is a new technique based on tissue-tracking from cine imaging …
-
Image-based computational modelling of coronary autoregulation with the primary aim of improving risk stratification of Alagille’s syndrome patients prior to liver transplantation
… pump function) using phasic volume changes and tissue-tracking, and showed that this robust methodology could improve disease staging. In Study 5, we developed and evaluated a novel tool for automated extraction of the thoracic aorta length from different CMR sequences to streamline pulse wave …