Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 21 for “"Tissue impedance"”.
-
In-Vivo Neural Tissue Impedance Measurements with a 126 Channel Silicon Microelectrode
… to understand the differing magnitudes of impedance changes in-vivo, comparing outcomes between currents sunk to a traditional headscrew, or to various locations on the probe itself. Leveraging the customizable and dynamically specifiable nature of microelectrodes on this device, hereto …
-
The impact of fine sensor spacing on complex tissue impedance spectra measurements in rabbit ventricular epicardium
… small sensors to complete complex composite impedance (uCI) measurements, whose amplitude and phase depend upon the tissue's resistive and capacitive properties. The goal of this study was to test the feasibility of using smaller electrodes with finer separations than sizes traditionally …
-
Non-linearity and Dispersion Effects in Tissue Impedance during Application of High Frequency Electroporation-Inducing Pulsed Electric Fields
… predictability in homogeneous and heterogeneous tissue masses. Therapeutic IRE and H-FIRE utilize source and sink electrodes inserted into or around the tumor to deliver the treatment. Prediction of the ablation size, for a set of parameters, can be achieved by the use of pre-treatment planning …
-
Calibration of ultrasound scanners for surface impedance measurement
… ultrasound scanners to measure surface impedance from reflection data. The method proposed uses calibration curves from known impedance interfaces. This plot, or calibration curve, may then be used, with interpolation, to relate measured grey level to impedance for the characterization …
-
Impedance Optimized Electric Pulses for Enhancing Cutaneous Gene Electrotransfer
… cell within a population present in treated tissue to derive electric pulse parameters. This results in fixed gene electrotransfer (GET) parameters that are not universally optimum. Slow progress towards the validation of a mechanism that explains this phenomena has also hindered its …
-
An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements
Electrical Impedance Spectroscopy techniques have long been used to investigate the frequency dependent electrical properties of biological tissues. Typically termed BioImpedance Spectroscopy, or BIS, these measurements are used in many medical and fitness-related applications. However, many of …
-
Computational and Experimental Investigation of Unintended and Enhanced Neural Stimulation in the Presence of Medical Implants
… by its surface-based delivery approach. The high impedance of superficial tissues limits current penetration and blocks deep nerve stimulation. To address this issue, this study is evaluating the alternative approach of using acupuncture needles to bypass the tissue impedance issue and deliver the …
-
Characterization and Implementation of an All-In-One Heating, Impedance, and Pulsing Device for Molecular Delivery Applications
… pulses or field strength, and the measurement of tissue impedance to indicate when successful electrical treatment has been applied.To date, no commercial or research machine exists which incorporates both improvements. In this work, the successful design and characterization of such an all-in-one …
-
Impedance Measurements as a Means to Improve the Biological Response of Gene Electrotransfer
When an electric field is locally applied to tissues in vivo the uptake of exogenous DNA can be greatly increased. This approach to gene transfer, called electroporation (EP) or gene electro transfer (GET), has potential applications in the treatment of skin disorders, vaccinations, some types of …
-
Investigating the Effect of Transcutaneous Electrical Stimulation on Enhancing Balance Control During Balance-Demanding Tasks
… the study delves into short-term adaptations in tissue impedance resulting from subsensory electrical stimulation, aiming to provide insights into its transformative potential on human performance and well-being. The primary objectives of the study include evaluating the efficacy of SES in …
-
Computational Modelling of Electrical Properties of Thyroid and Parathyroid Tissue
… associated with thyroid surgeries. Electrical Impedance Spectroscopy (EIS) based tissue differentiation recently emerged as a promising non-invasive technique that could enhance the tissues separation, and parathyroid preservation in a surgery setting. The aim of the work presented in this …
-
Development and Evaluation of Dry-Contact Electroencephalography (EEG) Sensors
… sensors indicates the unknown electrode-tissue impedance (ETI) is arguably the most difficult to deal with. While there are many modern techniques that aim to reduce the effects of the unknown ETI, none are regarded as extremely successful methods. Thus, researchers at the Institute of …
-
Arterial Perfusion Detection Method By Synchronous Detection
… created by unrelieved pressure, which causes tissue ischemia and subsequently damages the underlying tissue. This sequence of events is mainly centered on ischemia. Ischemia is a condition created by an insufficient flow of blood to an organ or part of an organ such as the skin. The outcome of …
-
Modular High-DR Artifact-Resilient Wearable EEG Headset with Distributed Pulse-Based Feature Extraction and Multiplier-Less Neuromorphic Boosted Seizure Detection
… >80dB CMRR in the presence of 1MΩ AE-to-AE input impedance (Zin) mismatch (89dB without mismatch), and 6) an AE-specific electrode-tissue impedance (ETI)-correlation-based circuit for motion artifact detection and suppression.
-
Quantification of power Doppler images to evaluate regional cerebral perfusion: Application of fractional moving blood volume (FMBV) in the neonate
… I investigated the feasibility of using novel impedance indices to evaluate tissue resistance as a complementary tool in the evaluation of tissue perfusion. The results of these studies show that FMBV is a reproducible technique that can be applied to neonatal images. A reference range for …
-
In-Vitro Biological Tissue State Monitoring based on Impedance Spectroscopy
… post-mortem state and changes of biological tissue impedance has been investigated to serve as a basis for developing an in-vitro measurement method for monitoring the freshness of meat. The main challenges thereby are the reproducible measurement of the impedance of biological tissues and …
-
Control of upper-limb functional neuromuscular electrical stimulation
… interesting observation was made relating to bioimpedance.<br/><br/>A study of bioimpedance measurements found a relationship between tissue impedance changes and muscle activity. Different methods for measuring bioimpedance where investigated and the results compared, before a practical …
-
Motion Artifact Reduction From Non-Contact ECG Recording Systems
… strategies, with focused attention on electrode-tissue impedance (ETI)-based reference signal techniques. To further this development, the study tackles this challenge by developing novel techniques to reduce MAs and improve the quality of capacitive ECG signals. The Adaptive Noise Cancellation …
-
Compensating for Signal Saturation Due to Electrostatic Noise in Electroencephalogram (EEG) Acquisition
… a direct connection to the skin. The electrode-tissue impedance (ETI) in both types of dry EEG sensory systems is highly associated with the hair-air domain which can cause erroneous measurements due to unknown impedance characteristics of hair, the potential of having heavy motion artefacts in …
-
Pracoviště pro měření měrného odporu biologických vzorků
Tato bakalářská práce se zabývá vylepšením metody vyvinuté na UVEE, která se využívá pro elektroporaci. Vylepšení spočívá v návrhu a realizaci snímače malých proudů s galvanickým oddělením.
Page 1 of 2