Results 1 to 19 of 19 for “"Titanium dental implants"”

  1. Integrated biomechanical, electronic and topographic characterization of titanium dental implants

    Titanium dental implants are medical devices used to restore the function entailed with the loss of one or several teeth. To obtain successful function over long periods, the dental implants must be sufficiently anchored in the bone to withstand the forces induced by for example chewing. Two …

    goteborg Repository record for Integrated biomechanical, electronic and topographic characterization of titanium dental implants (opens in a new tab)

  2. Development of antibacterial coatings for titanium dental implants based on different strategies

    … fracaso a medio y largo plazo de los implantes dentales fabricados en titanio sigue siendo significativo, debido principalmente a infecciones peri-implantarias. A pesar de que los antibióticos son altamente eficientes en el control de enfermedades infecciosas, la aparición de resistencias por …

    barcelona Repository record for Development of antibacterial coatings for titanium dental implants based on different strategies (opens in a new tab)

  3. Development of polymeric coatings with combined antifouling/antibacterial properties for titanium dental implants

    Titanium dental implants are a commonly used solution for the replacement of lost teeth. Even though the success rate is high, the number of infections related to the placement of the implant is still remarkable and may impair the proper function of the device, leading to health and economic costs. …

    barcelona Repository record for Development of polymeric coatings with combined antifouling/antibacterial properties for titanium dental implants (opens in a new tab)

  4. Nano Enhanced Surface Modification of Titanium Dental Implants for Improving Osseointegration and Biocompatibility

    Dental implants are prone to bacterial colonisation and infection which subsequently cause dental implant failure. Coating the dental implant with an antibacterial agent and a biocompatible agent can inhibit the bacterial colonisation and infection without disturbing the biocompatibility of the …

    plymouth Repository record for Nano Enhanced Surface Modification of Titanium Dental Implants for Improving Osseointegration and Biocompatibility (opens in a new tab)

  5. Influence of ultraviolet photofunctionalization on the surface characteristics of expired and unexpired manufactured titanium dental implants

    … characteristics of commercially available titanium dental implants with both expired and valid expiration dates, as well as different surface configurations.<br><br>Material and Methods: Four types of commercially available titanium implants with different surface characteristics (4.3x11mm, …

    freiburg-diss Repository record for Influence of ultraviolet photofunctionalization on the surface characteristics of expired and unexpired manufactured titanium dental implants (opens in a new tab)

  6. Accuracy and stability of titanium dental implants placed with s-CAIS: an in vitro and in vivo pilot study

    [ES] Los nuevos diseños de implantes dentales, junto con los avances digitales en la planificación quirúrgica, han dado lugar a la actualización de protocolos y técnicas quirúrgicas. El concepto de mínima invasión con la cirugía guiada de implantes, ha generado gran atención entre los clínicos y …

    salamanca Repository record for Accuracy and stability of titanium dental implants placed with s-CAIS: an in vitro and in vivo pilot study (opens in a new tab)

  7. In-vitro-Untersuchung zur Veränderung proinflammatorischer Genexpression in humanem Vollblut nach Kontakt mit plasmakonditionierten Implantatoberflächen

    … in human whole blood after contact with titanium implant surfaces after plasma treatment. Materials and methods: Grade 4 titanium dental implants were conditioned with low-pressure plasma (LPP) and atmospheric-pressure plasma (APP) and submerged in human whole blood in vitro. …

    cau-kiel Repository record for In-vitro-Untersuchung zur Veränderung proinflammatorischer Genexpression in humanem Vollblut nach Kontakt mit plasmakonditionierten Implantatoberflächen (opens in a new tab)

  8. Χαρακτηρισμός της επιφάνειας οστεοενσωματούμενων οδοντικών εμφυτευμάτων

    … last twenty years the number of osseointegrated dental implants used has been steadily increasing worldwide reaching today one million cases per year. The clinical success of dental implants is directly connected to their premature osseointegration. The chemical consistency and surface topography …

    greece Repository record for Χαρακτηρισμός της επιφάνειας οστεοενσωματούμενων οδοντικών εμφυτευμάτων (opens in a new tab)

  9. Effect of guided bone regeneration with rhBMP-2 on bone quality surrounding dental implants

    … osteogenesis in a bone defect surrounding a dental implant. While bone quantity at the implant interface has been investigated to evaluate stability of the implant system, bone quality is also responsible for determining mechanical response of bone around the implant. The objective of this …

    ohiolink Repository record for Effect of guided bone regeneration with rhBMP-2 on bone quality surrounding dental implants (opens in a new tab)

  10. Nanoindentation Properties Of Newly Formed Bone Surrounding Dental Implants Treated With E7-Modified Rbmp-2 Peptides

    Statement of Purpose: Use of titanium dental implants for treatment of partial or total edentulism has been well documented since the 1980s with consistent long term results. Osseointegration of these implants can be complicated by insufficient bone after healing of extraction sockets or systemic …

    uab Repository record for Nanoindentation Properties Of Newly Formed Bone Surrounding Dental Implants Treated With E7-Modified Rbmp-2 Peptides (opens in a new tab)

  11. Investigation of Designed Peptides for the Disruption of Bacterial and Mammalian Amyloid Systems

    … inhibition at a wound site and tethered to titanium dental implants to prevent oral biofilm infection. Next, the effects of the α-sheet peptides on Aβ in the context of AD were further examined. An increased rate of phagocytosis of Aβ oligomers in multiple cell lines was observed when cells …

    washington Repository record for Investigation of Designed Peptides for the Disruption of Bacterial and Mammalian Amyloid Systems (opens in a new tab)

  12. Functional studies of calcium enriched titanium surfaces.

    There exists a clinical requirement for dental implants which will enhance the speed of achievement of osseointegration, its maintenance, and biological and physical properties. Whilst commercially pure titanium remains the material of choice for implant fabrication, a promising approach to …

    ucl Repository record for Functional studies of calcium enriched titanium surfaces. (opens in a new tab)

  13. Titanium Corrosion is a Modifier of Peri-implant Health

    Dental implants are highly successful at replacing missing teeth and restoring Oral-Health Related quality of life. Despite a high rate of success, however, there remain a significant number of patients who develop peri-implant mucositis and peri-implantitis. The definition of success for implants …

    washington Repository record for Titanium Corrosion is a Modifier of Peri-implant Health (opens in a new tab)

  14. A prospective analysis of success and survival of haptic robotically driven dental implant placement.

    … prospective study was to assess survivability of dental implants placed using robotic computer aided implant surgery via Yomi® (Neocis, Inc. Miami, FL) after at least 1 year of functional loading. Secondary analysis included additional success and marginal bone loss outcomes after at least 1 year …

    wvu Repository record for A prospective analysis of success and survival of haptic robotically driven dental implant placement. (opens in a new tab)

  15. Development of hybrid coatings for osseointegration improvement of metal dental implants

    Los implantes de titanio presentan comprobada biocompatibilidad no obstante carecen de propiedades osteoinductoras. Las estrategias actuales de modificación superficial de los implantes no resultan plenamente efectivas en casos particulares de baja calidad del hueso receptor. La presente tesis …

    barcelona Repository record for Development of hybrid coatings for osseointegration improvement of metal dental implants (opens in a new tab)

  16. Fonctionnalisation de la surface du titane pour les implants dentaires

    … afin de développer de meilleurs modèles d'implants dentaires et d'optimiser leur ostéo-intégration. Cette fonctionnalisation a été réalisée en deux étapes ; on a commencé par la nano structuration de la surface de TiO2 par anodisation pour créer des sites réactifs sur les bords extérieurs …

    star-france Repository record for Fonctionnalisation de la surface du titane pour les implants dentaires (opens in a new tab)

  17. Nachuntersuchung von Zahnimplantaten aus Titan mit zementierten Vollzirkonbrücken auf Abutments aus Titan im Vergleich zu Hybridabutments aus Titan und Zirkonoxid

    Dentale Implantate dienen dem Ersatz fehlender Zähne und haben sich in den letzten Jahrzehnten als Behandlungskonzept etabliert. In den meisten Fällen werden zweiteilige Implantate eingesetzt, um die prothetische Richtung und die konturgebende Weichgewebsproblematik zu berücksichtigen. Neben …

    fu-berlin Repository record for Nachuntersuchung von Zahnimplantaten aus Titan mit zementierten Vollzirkonbrücken auf Abutments aus Titan im Vergleich zu Hybridabutments aus Titan und Zirkonoxid (opens in a new tab)

  18. On the influence of micro-and macroscopic surface modifications on bone integration of titanium implants

    Background: Osseointegrated titanium implants are routinely used in clinical denstistry as anchorage units for dental prostheses. Although the overall clinical results are good, there are clinical situations when an optimized implant healing is desirable, for instance in order to shorten healing …

    goteborg Repository record for On the influence of micro-and macroscopic surface modifications on bone integration of titanium implants (opens in a new tab)

  19. Strain analysis and fracture strength of different abutments for cement-retained crowns on an internal hexagon implant

    … for the Tapered Screw-Vent implant (Zimmer Dental, Carlsbad, CA, USA). Of these aftermarket abutments this is wide variation, from stock to custom abutments, as well as material differences such as zirconia, titanium, or a combination of the two. This study was performed in two parts: the …