Showing 1 to 20 of 60 for “"Titanium implant"”.
-
Direct Metal Laser Sintering of Titanium implant with Tailored structure and Mechanical Properties
… of fundamental knowledge about the laser and titanium powder material interactions, thus establishing the factors that influence the process-structure-properties relationships of the Direct Metal Laser Sintering process. Finally, a route for manufacturing customised craniofacial implants was …
-
A Feasibility Study of Laser-Assisted Titanium Implant Drilling for Periprosthetic Fracture Repair
… the feasibility of hand drilling through a titanium implant located in the femur. This is hypothesized to be achievable via laser-assisted drilling with carbide tools. A series of tests were conducted to measure the thrust force and torque with different shaped drill bits under dry- and …
-
Comparison between the fracture strength and failure mode of lithium disilicate, zirconia and titanium implant abutments
Eighty implants (FairTwo, FairImplant, Germany) having a length of 11.5 mm and a diameter of 4.5 mm were used to be restored with single lithium disilicate crowns (IPS emax CAD, Ivoclar Vivadent, Liechtenstein). Five types of abutments were used; Ti titanium (CopraTi-4, Whitepeaks, Germany), Zr …
-
Multifunctional titanium implant surfaces based on the attachment of natural biomolecules on catechol-rich plasma methacrylic thin films
… recently, the deposition of coatings on dental implants by wet chemical processes has been studied and it involves complicated protocols and leads to a high amount of produced wastes. Surface modification and coating of the implants through a plasma polymerization can offer a new, greener …
-
Development of hydroxyapatite and wollastonite coatings for orthopaedic implant biomedical applications
The project aims to develop orthopaedic implants for biomedical applications. At present, millions of people suffer from hip issues; therefore, total hip replacement surgery has become more common; thus, finding a better hip implant is imperative. This study uses the titanium implant as a substrate …
-
Development of In Vitro and In Vivo Modeling for the Evaluation of the Bone–Titanium Interface Under Cathodic Voltage-Controlled Electrical Stimulation
… infections are a major problem in orthopedic implant applications and a solution is needed that is safe and effective for the patient. Previous work has demonstrated that cathodic voltage-controlled electrical stimulation (CVCES) in combination with antibiotics is an effective solution when …
-
In-vitro-Untersuchung zur Veränderung proinflammatorischer Genexpression in humanem Vollblut nach Kontakt mit plasmakonditionierten Implantatoberflächen
… in human whole blood after contact with titanium implant surfaces after plasma treatment. Materials and methods: Grade 4 titanium dental implants were conditioned with low-pressure plasma (LPP) and atmospheric-pressure plasma (APP) and submerged in human whole blood in vitro. …
-
Osseointegration of novel silver-doped hydroxyapatite coated and acid-etched titanium implants in an ovine model
… periprosthetic infection of orthopaedic implants remains a common and costly cause of implant failure and revision. Novel materials and coatings have been developed in an effort to improve implant resistance to the onset of infection, including those utilising the antimicrobial properties …
-
Characterization of Surface Modified Orthopedic Implants for Their Antimicrobial Properties
… is 91%, and biofilm formation on orthopedic implants can lead to chronic infection with a rate of 40% in fracture wounds. Designing orthopedic implants that can self-regulate local infection and biofilm formation is beneficial for these patients. Polytetrafluoroethylene (PTFE) and …
-
Evaluation of the plaque affinity of different PEEK grades in comparison to titanium and zirconium dioxide
… of materials applied for the fabrication of implant abutments and dental materials. Materials and methods: Specimens were prepared from six different materials: three types of dental grade Polyetheretherketone (PEEK), one type of implant-grade PEEK, one type of titanium implant abutment …
-
Antimicrobial Properties of Graphite and Coal-Derived Graphene Oxides as an Advanced Coating for Titanium Implants
… infection (PJI) poses a significant risk to implanted patients, requiring multiple surgeries with high rates of reinfection. The primary cause of such infections is otherwise innocuous bacterial species present on the skin that have survived sterilization protocols. Antibiotic drugs have …
-
Assessing the clinical viability of one- and two-piece zirconia implants as alternatives to titanium-based restorations in the anterior mandible
… stress distribution and optical performance of titanium, two-piece zirconia, and one-piece zirconia implant systems at the mandibular central incisor. MATERIALS AND METHODS: Three finite element models were constructed for each implant system, restored with a multilayer zirconia crown (LayZir) …
-
In vitro Investigation of Mechanical Properties of Latest-Generation CAD-CAM Composites
… dental prostheses: fractures and debonding from titanium implant abutment (Ti-base). Specifically, the work focused on evaluating the mechanical performance of latest generation CAD-CAM composites compared to established lithium-based glass-ceramic material. Fatigue behavior was analyzed to …
-
Evaluation of a computer-assisted technique for distal locking of femoral intramedullary nails
… for our application, even in the presence of the titanium implant. A distal locking tool was designed that locks into the distal locking holes from within the intramedullary nail with high repeatability. The stresses predicted from a finite element analysis of the removal process predict maximum …
-
A systematic review on the effect of inorganic surface coatings in large animal models and meta-analysis on tricalcium phosphate and hydroxyapatite on periimplant bone formation
… review was to analyse studies using inorganic implant coatings and, in a meta-analysis, the effect of specifically tricalcium phosphate (TCP) and hydroxyapatite (HA) implant surface coatings on bone formation according to the PRISMA criteria. Inclusion criteria were the comparison to rough …
-
Desinfektion periimplantärer Läsionen mit kaltem Plasma. Eine in-vitro Studie.
… phosphoric acid gel [PAG]) on decontamination of titanium implant surfaces in-vitro. Materials and methods: Implants were inserted in concavities mimicking a bone defect at the implant recipient site. After contamination with E. faecalis, the first group has been treated with CAP for 3 min, the …
-
Biomechanics of short implants in the posterior mandible: titanium versus one- and two-piece zirconia implants
… behavior of 1-piece and 2-piece zirconia implant systems in comparison with a conventional titanium implant configuration in the posterior mandible, with particular emphasis on implant–abutment interface mechanics, peri-implant bone loading, and stress propagation toward the inferior …
-
Effect of Abutment Position on Retention after Cyclic Loading of Cantilevered Y-TZP FPDS
… positions on the retention of a three-unit implant supported cantilevered FPD restoration was measured and compared. Methods: The study included four groups (n=10) of cantilevered FPDs restorations, fabricated of monolithic zirconia. Prefabricated titanium implant abutments were used and …