Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Tomographic system"”.

  1. An image reconstruction algorithm for a dual modality tomographic system.

    … of methods are available to provide imaging systems for process tomography applications and seven imaging techniques are reviewed. Two modalities of tomography were chosen for investigation (i.e. Electrical Impedance Tomography (EIT) and optical tomography) and the proposed dual modality …

    sheffield-hallam Download PDF for An image reconstruction algorithm for a dual modality tomographic system. (opens in a new tab)

  2. Design and implementation of a miniaturized swept source spectral domain polarization sensitive optical coherence tomographic imaging system to diagnose glaucoma

    … Sensitive Spectral Domain Optical Coherence Tomographic System aims to detect early glaucoma symptoms and prevent vision loss that occurs due to late or no glaucoma diagnosis. In order to perform human clinical trials at partner hospitals across the country, a miniaturized and portable …

    texas Repository record for Design and implementation of a miniaturized swept source spectral domain polarization sensitive optical coherence tomographic imaging system to diagnose glaucoma (opens in a new tab)

  3. Monterey Bay acoustics tomography: ray tracing and environmental assessment.

    … Bay. The experiment will test a low-cost tomographic system for studying internal waves and surface waves. The five sites were determined to be the most optimal locations for acoustic signal acquisition, based on predicted eigenray simulation and oceanic environment assessment. The …

    nps Repository record for Monterey Bay acoustics tomography: ray tracing and environmental assessment. (opens in a new tab)

  4. Application of an Optical Tomography System to the Analysis of Horizontally Dispersed Bubble Flow

    … investigates the use of an optical tomography system as a non-intrusive measurement tool for the study of horizontal multiphase flow. Dispersed bubble flow of water and air is captured with a set of three high-speed video cameras. Bubble position data is reconstructed from the cameras's images …

    calgary Repository record for Application of an Optical Tomography System to the Analysis of Horizontally Dispersed Bubble Flow (opens in a new tab)

  5. Tomographic Approach to Human Hydration Assessment: Proof of Concept

    … changes in hydration. A practical and effective tomographic system is designed in simulation for hydration assessment. To improve blind inversions of high contrast objects, a novel regularization parameter selection procedure is introduced. The tomographic hydration assessment technique is …

    calgary Repository record for Tomographic Approach to Human Hydration Assessment: Proof of Concept (opens in a new tab)

  6. Frequency domain fluorescent molecular tomography and molecular probes for small animal imaging

    … a frequency domain fluorescent molecular tomographic system based on the heterodyne technique using a single source and detector pair for small animal imaging. In our system, the intensity of laser source is modulated to produce a diffuse photon density wave in the tissue. The phase of the …

    missouri Repository record for Frequency domain fluorescent molecular tomography and molecular probes for small animal imaging (opens in a new tab)

  7. Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4

    … computed tomography (NSECT) is a non-invasive, tomographic imaging technique with the ability to locate and quantify elemental concentration in a tissue sample. Previous studies have shown that NSECT has the ability to differentiate between benign and malignant tissue and diagnose liver iron …

    duke Repository record for Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4 (opens in a new tab)

  8. Measurement of gas bubbles in a vertical water column using optical tomography.

    … the application of optical fibre sensors to a tomographic imaging system for use with gas/water mixtures. Several sensing techniques for measurement of two component flow using non-intrusive techniques are discussed and their relevance to tomographic applications considered. Optical systems are …

    sheffield-hallam Download PDF for Measurement of gas bubbles in a vertical water column using optical tomography. (opens in a new tab)

  9. Μελέτη βιολογικών λειτουργιών με μοριακή τομογραφία φθορισμού

    … deal of interest in developing optical imaging systems under optimal experimental conditions. A novel system has been implemented that enables three dimensional (3D) imaging of fluorescent probes in whole animals using a non-contact set up, in parallel with a 3D surface reconstruction algorithm. …

    greece Repository record for Μελέτη βιολογικών λειτουργιών με μοριακή τομογραφία φθορισμού (opens in a new tab)

  10. Tomografía ultrasónica para la evaluación de daño por gradiente en materiales cementantes

    [ES] Hoy en día, los materiales cementicios están presentes en la gran mayoría de las infraestructuras de nuestro entorno, como pueden ser el hormigón y el mortero, debido a su bajo coste y sus características mecánicas estructurales y de durabilidad. Pese a todo, estas se ven degradadas por …

    upv Repository record for Tomografía ultrasónica para la evaluación de daño por gradiente en materiales cementantes (opens in a new tab)