Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 33 for “"Tomotherapy"”.
-
Conformal Radiation Therapy with Cobalt-60 Tomotherapy
… normal tissue. One form of IMRT is known as tomotherapy. Tomotherapy achieves dose conformity to a tumor by modulating the intensity of a fan beam of radiation as the source revolves about a patient. Current available tomotherapy machines use x-ray linear accelerators (linacs) as a source of …
-
Novel techniques towards improving helical tomotherapy delivery and quality assurance
… OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] TomoTherapy (TomoTherapy, Inc., Madison, WI), an Image-Guided Intensity Modulated Radiation Therapy (IG-IMRT) modality, has been used to treat a variety of cancer sites. While radiation therapy, a rapidly expanding field, has increased in accuracy …
-
Optimizing Of Spoiler Thickness For Total Body Irradiation (TBI) Utilizing Tomotherapy Technology
Delivering total body irradiation (TBI) with a Tomotherapy unit presents a unique challenge: minimizing lung dose while achieving a high skin dose. Acrylic spoilers offer a potential solution by slightly attenuating the incident photon beam, and therefore, reduce the lung dose. The spoilers can …
-
Helical tomotherapy for total marrow and total skin irradiation : Optimisation, verification, and clinical results
… of all types of uncertainties are essential. A TomoTherapy device (Accuray Inc., Madison, WI, USA) is an RT device with a linear accelerator mounted on a slip-ring construction, giving it the ability to irradiate while continuously rotating around the patient, very similar to a CT scanner but …
-
Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification
<p>Helical tomotherapy systems have the unique attribute of using sinograms as a machine input and a machine output. These sinograms have well understood properties that may allow for operational changes that simplify and/or improve radiation treatment.</p> <p>In the first part of this work, the …
-
Evaluation of Tumor Localization in Respiration Motion-Corrected Stereotactic Body Radiotherapy Patients Treated with TomoTherapy.
… Respiratory motion is of particular concern for TomoTherapy (Accuray, Inc, Sunnyvale, CA), which utilizes a continuously rotating gantry (maximum speed of 12 seconds per rotation) synchronized with a linearly moving couch to irradiate a target volume in a helical manner(8,9). The interplay …
-
Development of a Novel Technique for Predicting Tumor Response in Adaptive Radiation Therapy
… were<em> </em>imaged and treated with helical tomotherapy was constructed. The data was then modeled using locally weighted regression. This model predicts future tumor volumes and masses and the associated confidence intervals based on limited observations during the first two weeks of …
-
Postmastectomy radiation therapy for patients with tissue expanders
… techniques (tangential 3DCRT, VMAT and helical Tomotherapy) was evaluated against the measured positional errors. Results showed that interfractional positional errors were generally small, but errors larger than 1.5 cm were also observed. The interfractional positional variations arise from a …
-
Investigation of Buildup Dose for Therapeutic Intensity Modulated Photon Beams in Radiation Therapy
… different IMRT modalities: between Helical TomoTherapy and traditional opposed tangential beams, solid IMRT and multileaf collimator (MLC)-based IMRT techniques. Solid IMRT, as an alternative to MLC, achieves prescription dose distribution objectives, according to our study. Measurements and …
-
The Role of Cobalt-60 Source in Intensity Modulated Radiation Therapy: From Modeling Finite Sources to Treatment Planning and Conformal Dose Delivery
… a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and …
-
Clinical Applications Of Advanced Rotational Radiation Therapy
… algorithm and its applications in helical tomotherapy dose delivery. We explore the limits of the system by applying it to challenging clinical cases of total marrow irradiation (TMI) and stereotactic radiosurgery (SRS). We also analyze the feasibility of alternative fractionation schemes …
-
Implementierung innovativer Techniken – helikale Bestrahlung (TomoTherapy®), roboterassistierte Radiochirurgie (CyberKnife®) und volumetrische Arc-Therapie (Rapid Arc®) – in die radioonkologische Therapie zur Anwendung bei Ganzkörper-/ Knochenmarkbestrahlung und lokal fortgeschrittenem Zervixkarzinom
… wie des CyberKnife® (CK) und der helikalen TomoTherapy® (HT) zu verbessern. Methode: Zervixkarzinom: Elf Patientinnen erhielten eine primäre Radiochemotherapie. Zusätzlich zur perkutanen Strahlentherapie erfolgte statt der Brachytherapie (BT) eine CK- Behandlung. Die Basis der vorliegenden …
-
ORGAN MOTION AND IMAGE GUIDANCE IN RADIATION THERAPY
… anatomic sites were studied with Helical TomoTherapy unit. The pre-treatment mega voltage computed tomography (MVCT) provided the real-time tumor and organ shift coordinates, and can be used to improve the accuracy of patient positioning. The interfractional system errors and random errors …
-
Patient-specific quality assurance for IMRT
… evaluated the dosimetric accuracy of a helical TomoTherapy system which resulted in a benchmark being established for dosimetric accuracy in heterogeneous materials. The MatriXX study evaluated the performance of the MatriXX Detector to determine if it could be used as a substitute for …
-
Vergleich unterschiedlicher Bestrahlungstechniken am Beispiel des Analkanalkarzinoms
… und helikaler Rotationstechnik (RapidArc®, Tomotherapy®) nach identischer Konturierung geplant (Varian Eclipse®, Tomotherapy®) und verglichen. Das Zielvolumen (PTV 45) umfasste die Primärtumorregion und den beidseitigen pelvinen und inguinalen Lymphabfluss mit einer Einzeldosis von 1,8 Gy in …
-
Χαρακτηρισμός δοσιμέτρων nanoDot οπτικής φωταύγειας (optically stimulated luminescent dosimeters - OSLDs) για in-vivo δοσιμετρία στην ακτινοθεραπεία
… TomoHelical, χρησιμοποιώντας το σύστημα TomoTherapy (Accuray Inc, CA, USA), με δυναμικώς κινούμενα διαφράγματα (TomoEDGE Dynamic Jaws).
Page 1 of 2