Corneal hydration and the accuracy of Goldmann tonometry.
… of corneal swelling on the accuracy of Goldmann tonometry estimates of intraocular pressure (IOP). In the first experiment, central corneal thickness (CCT, ultrasonic pachymetry), IOP (Goldmann tonometry) and corneal curvature (keratometry) was measured in one eye of 25 subjects every two hours …
-
Tonometry and biomechanics of the cornea in contact lens wear
… (differences < 1.45 mmHg).Accurate RBT and ORA tonometry (within 2 mmHg) was possible with low minus power (range -0.50 to -6.00 D); moderate modulus of elasticity (< 0.75 MPa); thin silicone hydrogel (Acuvue Oasys) and hydrogel (Frequency XC; Acuvue 1-Day Moist) contact lenses in situ.Multiple …
-
Cardiac Syndrome X: assessment of endothelial function by peripheral arterial tonometry
… function, using non-invasive peripheral arterial tonometry, in a cohort of patients which included healthy patients, patients with coronary artery disease and patients with CSX, from Italian-speaking Switzerland. Methods: We examined systemic endothelial function in a cohort of 37 patients: 8 …
-
Tonometry agreement and corneal biomechanical features in normal, glaucomatous and keratoconic eyes
… tonometer (GAT). Studies often report inter-tonometry agreement and bias of new tonometers against GAT. However, only a minority have studied the proportionate bias and factors that influence the inter-tonometry bias of a new tonometer. The inter-tonometry agreement is vulnerable to the …
-
Effect of numerical modelling assumptions on the simulated corneal response during Goldmann applanation tonometry
… (IOP) obtained from Goldmann Applanation Tonometry (GAT). However, not much is known about the in uence of corneal material properties, especially in a clinical setting. Several numerical studies have been conducted in an attempt to quantify the in uence of corneal material properties on …
-
Evaluation of gender differences in endothelium-independent dilation in healthy adults using peripheral arterial tonometry
Peripheral arterial tonometry (PAT) is a non-invasive method used to evaluate vascular function. PAT is often used to measure digital pulsatile volume changes in response to reactive hyperemia, which provides a measure of endothelium-dependent dilation (EDD). Reactive hyperemia does not allow one …
-
Evaluation of Ocular Pulse Amplitude-related Parameters measured by Dynamic Contour Tonometry and Ocular Blood Flow Analyzer
… design. OPA was measured using dynamic contour tonometry (DCT). Pulse amplitude (PA), pulse volume (PV), and pulsatile ocular blood flow (POBF) were measured using ocular blood flow analyzer (OBFA). Intraocular pressure (IOP) was measured by Goldmann applanation tonometry (GAT), DCT and OBFA. …
-
Computer-assisted image analysis of endometrial edema and follicular wall attributes and transrectal follicular tonometry in estrous mare
… (mean area under the curve) and follicular tonometry (mean pounds per square inch). Mean endometrial NPV in only the uterine body changed over time from ovulation (p< 0.001) in groups 1, 3, and 4. In all 4 groups, there was an inverse relationship between the changes in subjective …
-
The validity and reliability of intraocular pressure measurement using rebound tonometry in children with ocular and systemic disease
… main objectives: 1. The validity of Rebound Tonometry (RBT) measurements in children. 2. The reliability of suboptimal RBT readings and the relationship between co-existing characteristics and these measurements. 3. The reliability of suboptimal RBT measurements in children with heritable …
-
DEVELOPMENT OF A NEW INTRAOCULAR PRESSURE MEASUREMENT DEVICE: SELF-TONOMETRY DEVICE FOR MONITORING OF INTRA-OCULAR PRESSURE (STOP) FOR GLAUCOMA
Background Glaucoma is one of the commonest causes of blindness in the world. The majority of treatment strategies target the reduction of intraocular pressure (IOP). Currently, IOP is only measured once in the outpatient clinic by a specialist and this "snapshot" IOP is used as the representative …
-
Development and Implementation of Telemetry Devices to Identify and Characterize Sources of Intraocular Pressure Variability in Rats
… affect it as IOP is typically monitored using tonometry. Tonometry is a common tool used by clinicians and researchers to measure IOP noninvasively. It provides a good estimate of IOP mean but not variance because data collection takes time. Readings can also be influenced by subject stress and …
-
Non-invasively obtained central blood pressure : barriers and strategies to its use in practice.
… mainly based on the technique of applanation tonometry. However, CBP measured has not been widely adopted in clinical practice. One of the possible gaps is that tonometry-based measurement requires some skills and time to perform and it is a relatively expensive technique. Besides, the …
-
Χρήση της ρεοκαρδιογραφίας και της αρτηριακής τονομετρίας ως μεθόδων πρόβλεψης του αντιυπερτασικού αποτελέσματος: σύγκριση μεταξύ αποκλειστή υποδοχέων αγγειοτενσίνης ΙΙ και διουρητικού
… was to evaluate the usefulness of arterial tonometry and impedance cardiography as methods of predicting the antihypertensive effect, as well as to compare an angiotensin II receptor blocker (olmesartan) with a diuretic (chlorthalidone) regarding the antihypertensive effect and the effect on …
-
Parylene-based wireless intraocular pressure sensor for glaucoma research
… glaucoma, a degenerative eye disease. Currently, tonometry is used to measure IOP in research subjects. In this technique, the deflection of the cornea due to a known applied force is measured and IOP values are derived based on the invalid assumption that the corneas of all eyes are very similar. …
-
Biomechanical aspects of the anterior segment in human myopia
… human sclera and cornea in vivo using Schiotz tonometry (ST), rebound tonometry (RBT, iCare) and the Ocular Response Analyser (ORA, Reichert). Significant differences in properties were found to occur between scleral quadrants. Structural correlates for the differences were examined using …