Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Torso model"”.

  1. Development and Implementation of High Fidelity Human Models for the Investigation of Blast and Non-Penetrating Projectile Impact

    … The development of high-fidelity human torso and head-neck-torso models are presented here. These models are employed in blast and non-penetrating projectile impact simulations in order to demonstrate the value of the models and the associated simulation approach in assessing potential …

    unm Repository record for Development and Implementation of High Fidelity Human Models for the Investigation of Blast and Non-Penetrating Projectile Impact (opens in a new tab)

  2. Soft Materials under Air Blast Loading and Their Effect on Primary Blast Injury

    … Initially, 1-D finite element and mathematical models were developed to investigate a variety of soft materials commonly utilized in ballistic and blast protection. Foams, which have excellent characteristics in terms of energy absorption and density, can be used in conjunction with other …

    waterloo Repository record for Soft Materials under Air Blast Loading and Their Effect on Primary Blast Injury (opens in a new tab)

  3. Models and methods for bird strike load predictions

    … some simplifying assumptions made regarding the modeling of the bird material. Yet, the open literature on the subject includes no comparative study to systematically investigate the effect of the projectile shape or bird model material on the accuracy of impact loads analyses. This research …

    wichita-thes Repository record for Models and methods for bird strike load predictions (opens in a new tab)

  4. Observability and the inverse problem in electrocardiography

    … the information obtained noninvasively on the torso surface. The formulation of the problem leads to a Cauchy problem for the Laplace's equation, i.e., a harmonic function is sought in some region, given that the values of the function and its normal derivative are specified only on some part …

    ttu Repository record for Observability and the inverse problem in electrocardiography (opens in a new tab)

  5. Three-dimensional Multiscale Modelling and Simulation of Atria and Torso Electrophysiology

    … understood. Multiscale anatomical and functional models of the heart are a new technological framework that can enable the investigation of the heart as a complex system. This thesis is centred in the construction of a multiscale framework that allows the realistic simulation of atrial and torso …

    upv Repository record for Three-dimensional Multiscale Modelling and Simulation of Atria and Torso Electrophysiology (opens in a new tab)

  6. Do the Twist: Toward Agile Control of an Axially Twisting Robotic Quadruped

    … robots lack any degrees of freedom in the torso, opting instead for a simpler, single, rigid body. This rigidity results in the legs competing for workspace and power optimality during locomotion. Furthermore, although some quadrupeds do feature a flexible torso, most research primarily …

    penn Repository record for Do the Twist: Toward Agile Control of an Axially Twisting Robotic Quadruped (opens in a new tab)

  7. Cardiomagnetic source imaging

    … obtained by using different current source models, was investigated. In addition, the effect of the torso model on the localization accuracy was examined. In some studies, also body surface potential mapping (BSPM) data were used for comparison purposes. A high impact was given to clinical …

    aalto Repository record for Cardiomagnetic source imaging (opens in a new tab)

  8. Effect of Corrective Surgery on Lower Limb Mechanics in Patients with Crouch Gait

    … gait analysis data into a finite element model, develop a model of sufficient complexity to evaluate a range of outcomes by which to judge the efficacy of a surgical procedure, analyze the change between pre- and post-operative models and the changes between models with different surgical …

    boise Repository record for Effect of Corrective Surgery on Lower Limb Mechanics in Patients with Crouch Gait (opens in a new tab)

  9. Non-invasive electrical imaging of the heart

    … electrical images of the heart from non-invasive torso surface signals is presented. It is shown reliable electrical images of the heart can be obtained under a controlled environment. This has been demonstrated using an anatomically realistic boundary element porcine torso model. The procedures …

    auckland-ms Repository record for Non-invasive electrical imaging of the heart (opens in a new tab)

  10. Is my musculoskeletal model complex enough? The implications of six degree of freedom lower limb joints for dynamic consistency and biomechanical relevance

    Studies have shown that modeling errors due to unaccounted for soft-tissue deformations – known as soft-tissue artifact (STA) – can reduce the efficacy and usefulness of musculoskeletal simulations. Recent work has proven that adding degrees of freedom (DOF) to the joint definitions of a …

    temple Repository record for Is my musculoskeletal model complex enough? The implications of six degree of freedom lower limb joints for dynamic consistency and biomechanical relevance (opens in a new tab)

  11. A Novel Distractive and Mobility-Enabling Lumbar Spinal Orthosis for Treating Mechanical Low Back Pain

    … of life. Methods: A mechanical analog upper torso model and programmable robotic testing platform were used to design features of the new prototype (DMO2): a mobility-enabling component (MEC) and a distractive force component (DFC). The DMO2 prototype was tested in a robotic testing platform …

    tenn-hsc Repository record for A Novel Distractive and Mobility-Enabling Lumbar Spinal Orthosis for Treating Mechanical Low Back Pain (opens in a new tab)

  12. Electrocardiographic Consequences Of Electrical And Anatomical Remodeling In Diabetic And Obese Humans

    … of the platform calculates BSPs from a bidomain-model of myocyte TMPs and torso anatomy. The platform also contains a Cardio-myocyte TMP Estimation Module in which an innovative method, named regularized waveform identification: RWI), was developed. It is a new approach used to reconstruct the …

    wustl Repository record for Electrocardiographic Consequences Of Electrical And Anatomical Remodeling In Diabetic And Obese Humans (opens in a new tab)

  13. Modelling cardiac activation from cell to body surface

    … through to potentials on the surface of the torso. This integrated modelling framework is based on three spatial scales. At the smallest spatial resolution, several cardiac cellular models are implemented that are used to represent the underlying cellular electrophysiology. A bidomain …

    auckland-ms Repository record for Modelling cardiac activation from cell to body surface (opens in a new tab)

  14. Μελέτη επιφανειακών και διαρρεόντων ηλεκτρομαγνητικών κυμάτων διεγειρόμενων σε διατάξεις φορτωμένες με ανισότροπα ή βιολογικά υλικά

    … The difficulty in studying the corresponding models lies in their extremely large dielectric constant accompanied by very large losses (electrolyte behavior). These features lead the known mathematical techniques to an inability to describe the inherent phenomena. The particular contribution …

    greece Repository record for Μελέτη επιφανειακών και διαρρεόντων ηλεκτρομαγνητικών κυμάτων διεγειρόμενων σε διατάξεις φορτωμένες με ανισότροπα ή βιολογικά υλικά (opens in a new tab)

  15. Mapping of the electrical activity of human atria. Multiscale modelling and simulations

    … sistemas de mapeo multi-electrodo a través de modelos y simulaciones computacionales. Para ello, desarrollamos modelos realistas multi-escala con el objetivo de simular actividad eléctrica auricular reentrante, en primer lugar en una lámina de tejido auricular, y en segundo lugar en las …

    upv Repository record for Mapping of the electrical activity of human atria. Multiscale modelling and simulations (opens in a new tab)

  16. Towards automated disability assessment of upper limb movement after stroke

    … the movements according to accepted clinical model. This laboratory setup would require a highly skilled bio-mechanics' scientist and therapist to locate the anatomical landmarks and to analyze the kinematics data. Furthermore, the cost and complexity of the setup limits the amount of …

    auckland-ms Repository record for Towards automated disability assessment of upper limb movement after stroke (opens in a new tab)