Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 35 for “"Trans-tibial"”.
-
Cutaneous sensitivity in unilateral trans-tibial amputees
The aim of this research was to examine tactile sensitivity in the skin of the leg and foot sole of healthy control subjects and below knee amputees and to examine its association with balance. For control subjects, the glabrous skin of the foot had higher sensitivity compared to the hairy skin of …
-
Activity Recognition for Trans-Tibial Prosthesis Users
… on data collected from eleven subjects with trans-tibial amputation. Data was collected while the subjects performed an hour long semi-structured activity protocol. The activity protocol included donning and doffing the prosthesis, sitting in various positions, standing, walking, and using …
-
Normative Database of Adult Unilateral Trans-Tibial Amputee Gait
… of gait characteristics for adult, unilateral trans-tibial amputees specific to the protocol for the Center of Human Kinetic Studies. Subjects were community ambulators with established gait patterns and had used their current prosthesis for greater than three months. Kinematic, kinetic, and …
-
Dynamic interface pressure measurement : comparing two trans-tibial socket concepts
… study was to compare two socket designs for the trans-tibial prosthetic case. Pressure distribution studies, comfort and functionality are potential methods of assessing and distinguishing the conceptual differences. This study investigated pressure distribution at the stump-socket interface, …
-
Pressure distribution at the stump socket interface in trans-tibial amputees
… is one of the most popular prosthesis for trans- tibial amputees. However, an ideal patellar tendon bearing socket is one which has an even pressure distribution and at the same time the sensitive areas of the stump are adequately guarded. Although many studies have been carried out to …
-
Motor control in persons with a trans-tibial amputation during cycling
… during locomotion. A person with a uni-lateral trans-tibial amputation has lost the foot, ankle joint, and muscles crossing those joints, hence the residuum becomes the new terminus of the motor system. The amputee must now adjust to the additional challenges of utilizing a compromised motor …
-
Soft tissue control during hydrostatic shape capture for trans-tibial prosthetic provision
… of the gait cycle and minimal rotational and transverse movements. To eliminate these issues, the socket should match the surface and volume of the residuum. Of the various methods for creating a prosthetic socket, hydrocasting is the only one which offers volume- and surface-matching under …
-
Advanced tuning of a trans-tibial prosthesis using motion capture and visualisation
A transtibial prosthetic alignment is a three dimensions interrelationship between a socket and a prosthetic foot. The prosthetic alignment aims to achieve the most suitable limb position for desired function and comfort. The alignment is tuned through three alignment stages; bench, static and …
-
The influence of the mechanical properties of trans-tibial prostheses on amputee performance
Achieving the required functionality of a trans-tibial prosthesis during the stance phase ofgait (e.g., shock absorption, close to normal roll-over characteristics, and smooth transitioninto swing) depends on the "Amputee Independent Prosthesis Properties" (AIPP), definedhere as the mechanical …
-
Trans-tibial socket design variations and their influence on static and dynamic pressure patterns
… was to test whether the distal end loading in a trans-tibial socket is affected by modifications in the patellar tendon, medial tibial flare and lateral tibial flare areas. The Strathclyde CAD/CAM system was used to design and manufacture six sockets for one patient. Four sockets had …
-
Patellar Tendon Morphology in Trans-Tibial Amputees Utilizing a Prosthesis with a Patellar-Tendon-Bearing Feature
… design feature used in individuals with trans-tibial amputations. As the patellar tendon in the knee of residual limb is subjected to the perpendicular compressive force not commonly seen in normal tendon loading, it is possible for tendon remodeling and degeneration to occur over time; …
-
A study of the interface stresses in trans-tibial sockets : a comparison of PTB and hydrocast sockets
… claimed that in most cases, the concept of load transfer to areas such as the patellar tendon, medial flare and condyles of the tibia is ineffective and uncomfortable. His belief is that the most effective socket is one that relies on “hydrostatic principles” for transfer of load. The current …
-
Development of a Prosthetic Biofeedback Method and Device to Measure Quality of Fit for Trans-Tibial Amputees
… In particular, neuropathy complicates transition of a new amputee to using a prosthetic socket crucial for their quality of life by reducing -or in some cases completely hindering- tactile sensation and healing in the residual limb. The objectives of this thesis are to: 1) create a …
-
The development and evaluation of a novel passive approach to maintaining residuum volume in trans-tibial amputees
… forces. For the first aim, an Instrumented Trans-tibial Prosthesis (ITTP) was developed. The socket was designed with a configurable distal void and could also be used in conjunction with a commercially available pump. For the second aim and prior to conducting the main study, the …
-
Trans-tibial prosthetic system design and benefits for the amputee, service providers and society : an evidence based clinical study
Two trans-tibial socket concepts are in regular use in prosthetic clinics. These may be categorised as the "hands-on" (hand casting) concept and "hands-off' (pressure casting) concept which, in addition to the distinctive casting methods, require different liner materials and components to create …
-
The effect of transverse rotation and longitudinal translation between prosthetic components during the gait of unilateral trans-tibial amputees
… phase of amputee gait, considerable forces are transmitted across the residual limb socket interface. These loads and associated gait patterns can be altered by introducing compliant elements into the prosthesis. However, previous studies have failed to adequately describe the effects that …
-
“Trans-Tibial Amputation as a Model to Evaluate the Role of Cutaneous Sensation, Proprioception and Muscular Strength on Balance Performance”
… on balance performance in unilateral traumatic trans-tibial amputees (TTA) under two different conditions, quiet stance and squatting. We proposed that cutaneous sensation, proprioception and strength are reduced in the non-amputated side of TTA. In addition, the center of pressure velocity …
-
The effects of walking speed and an uneven surface on dynamic stability margins in young adult subjects with and without traumatic unilateral trans-tibial amputations
… adults and in adults with unilateral traumatic trans-tibial amputations (TTA). To date, studies have not controlled for walking speed over an uneven surface in a patient population. We hypothesized that: 1) DSMs would increase over the uneven rocky surface (URS) for both groups, 2) DSMs would be …
-
Analysis of Unique Myoelectric Characteristics in Lower-Extremity Musculature During Locomotive State Transitions
… is the ability to safely and dynamically transition from one locomotor state to another. Switching between level-ground, ramp, and stair locomotion poses an increased risk as lower-extremity functionality is compromised. Powered prosthetics have been proposed as a solution to this problem. …
-
The effectiveness of total surface bearing compared to specific surface bearing prosthetic socket design on health outcomes of adults with a trans-tibial amputation: a systematic review.
… Inclusion criteria Types of participants Trans-tibial amputees aged 14 years and older utilising a TSB or SSB prosthesis. Types of interventions and comparators The intervention was the TSB and the comparator was the SSB design. Types of studies This review considered all relevant …
Page 1 of 2