Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"Transducer design"”.

  1. FSR based force torque transducer design

    This thesis report discusses the design, construction and calibration of two force-torque transducers for use in a force control override of a rate control system. Pre-loaded force sensing resistors were used in a computer model to determine the 6-umber and location of sensors necessary to resolve …

    nps Repository record for FSR based force torque transducer design (opens in a new tab)

  2. Passive radiosonde transducer design for remote pressure sensing applications

    … control system. The current work describes the design of a totally implantable microsensor for biomedical applications with the aim to monitor and measure the epidural intracranial pressure . The implanting microsensor is basically an RLC device in which capacitance varies with fluid pressure. …

    njit Repository record for Passive radiosonde transducer design for remote pressure sensing applications (opens in a new tab)

  3. Ultrasonic transducer design: Feasibility as parametric echosounder in shallow water

    … particularly with the evolution of ultrasonic transducers. Operation frequency, transmission power, bandwidth and directivity are key factors in the acoustic methods applied to fishing. In addition, other aspects of research are becoming more relevant in this sector, such as the study of …

    upv Repository record for Ultrasonic transducer design: Feasibility as parametric echosounder in shallow water (opens in a new tab)

  4. Multilayer graphene-based capacitive micromachined ultrasonic transducer design, manufacturing, and characterization

    … using a capacitive micromachined ultrasonic transducer (CMUT) receiver as an exemplar MEMS sensor. Modeling showed a >4x improved mechanical compliance and bandwidth attributable to the lower mass and lower internal stress of MLG membranes. Finally, a proof-of-concept CMUT was fabricated and …

    texas Repository record for Multilayer graphene-based capacitive micromachined ultrasonic transducer design, manufacturing, and characterization (opens in a new tab)

  5. The CMDS flow-rate and conductivity transducer : design, manufacture and testing

    Beginning from preliminary design constraints and functional requirements, a custom Flow-Rate And Conductivity Transducer (FRACT) was conceived, designed, and built for use in situ aboard the spinning rotor of the Centrifugal Membrane and Density Separation (CMOS) Research centrifuge. It was …

    uvic Repository record for The CMDS flow-rate and conductivity transducer : design, manufacture and testing (opens in a new tab)

  6. Application and development of finite element techniques for transducer design and analysis

    … times of pulses transmitted between an array of transducers that surround the region. Central to the development of OAT is the availability of low frequency (< 500 Hz), low Q (< 4), light (< 250 kg), and efficient (> 50 %) sound sources that can operated at depths in excess of 500 m. Following a …

    birmingham Download PDF for Application and development of finite element techniques for transducer design and analysis (opens in a new tab)

  7. A 6-DOF Force Transducer Design from an Existing Rocket Payload Attachment Fitting

    … one solution that creates a direct reading force transducer to monitor the forces and moments experienced by the spacecraft rather than inferring forces from accelerometer readings as is currently practiced. In order to minimize costs, it is desired that the transducer is designed out of the …

    odu Repository record for A 6-DOF Force Transducer Design from an Existing Rocket Payload Attachment Fitting (opens in a new tab)

  8. Acoustic transducer design for active reflection cancellation in a finite volume wave propagation laboratory

    This thesis describes the design, fabrication and experimentally obtained electro-acoustic response of an acoustic transducer suite constructed for use in the Wave Propagation Laboratory (WaveLab) at ETH Zürich. Wave-Lab aims to immerse a physical acoustic experiment within a real-time virtual …

    texas Repository record for Acoustic transducer design for active reflection cancellation in a finite volume wave propagation laboratory (opens in a new tab)

  9. Design and Testing of Low Cost Piezoelectric Film Ultrasonic Transducers

    … to the necessary use of broadband ultrasonic transducers over the conventional narrowband ones. A relatively new material that can provide a broadband response, is the piezoelectric film, polyvinylidene fluoride. The focus of this thesis is to look at the design, construction, and testing of …

    sask Repository record for Design and Testing of Low Cost Piezoelectric Film Ultrasonic Transducers (opens in a new tab)

  10. Experimental and Analytical Characterization of a Transducer for Energy Harvesting Through Electromagnetic Induction

    … recent efforts to model a novel electromagnetic transducer design that is intended for use in energy harvesting. The thesis details methods of experimental characterization as well as model validation. Also presented are methods of state space and parametric modelling eforts. In addition, this …

    vt Repository record for Experimental and Analytical Characterization of a Transducer for Energy Harvesting Through Electromagnetic Induction (opens in a new tab)

  11. Models for computing the directional radiation of sound from sources on a rigid cylindrical baffle

    … cylindrical baffle are derived for three sonar transducer design configurations: two rectangular designs (Segment and Patch) and one circular configuration (Disk). The derivation includes both application and an extension of developments by previous theorists. A computer program based on the …

    nps Repository record for Models for computing the directional radiation of sound from sources on a rigid cylindrical baffle (opens in a new tab)

  12. Development of a heterodyne interferometer for nanometer scale displacement measurement

    … measurements. High resolution displacement transducers are employed in numerous applications, including vibration analysis, surface profiling, position control, tilt meters, and non-destructive quality evaluation of solid parts. The University of Victoria Institute for Robotics and …

    uvic Repository record for Development of a heterodyne interferometer for nanometer scale displacement measurement (opens in a new tab)

  13. Novel Structural Design of a Piezo Transducer for Roadway Power Harvesting Applications

    … roadway power harvesting project was started to design and produce a working prototype of a piezoelectric based power harvesting aimed at harvesting power from vehicles. The system is composed of a rubber speed bump with arrays of piezoelectric transducers. The transducers are connected to power …

    carleton Repository record for Novel Structural Design of a Piezo Transducer for Roadway Power Harvesting Applications (opens in a new tab)

  14. The investigation of a non-invasive oximeter and the further development of an extracorporeal oximeter

    … oximeter. In this investigation a noninvasive transducer was designed and tested. The transducer design was deemed unworkable because it did not respond to changes in the per cent of the hemoglobin saturated with oxygen of blood under the skin. The second half of this thesis deals with the …

    vt Repository record for The investigation of a non-invasive oximeter and the further development of an extracorporeal oximeter (opens in a new tab)

  15. Passive materials for high frequency piezocomposite ultrasonic transducers

    … mean there is great potential for commercial transducers far superior to conventional devices currently in clinical use. This Thesis reports the fabrication and characterisation of passive materials suitable for use in high frequency piezocomposite transducer devices. Epoxy composites have …

    birmingham Download PDF for Passive materials for high frequency piezocomposite ultrasonic transducers (opens in a new tab)

  16. Orthoplanar Spring Based Compliant Force/Torque Sensor for Robot Force Control

    … been developed. This thesis presents methods of designing, testing, and implementing the sensor on a robotic system. The sensor uses an orthoplanar spring equipped with Hall-effect sensors to measure one component of force and two moment components. Its unique design allows for simple and cost …

    usf Repository record for Orthoplanar Spring Based Compliant Force/Torque Sensor for Robot Force Control (opens in a new tab)

  17. Compensated Row-Column Ultrasound Imaging System

    … be done in two main ways: mechanically moving a transducer over a region of interest and using a fixed 2-D transducer. Mechanical motion introduces unwanted artifacts and increases image acquisition time, so a fixed 2-D is usually preferred. However, a fully addressed 2-D array will require a …

    waterloo Repository record for Compensated Row-Column Ultrasound Imaging System (opens in a new tab)

  18. Finite impulse response utilizing the principles of superposition

    … (SAW) devices. The critical parameter in any FIR design in the impulse response length, which must be optimized for the given design specifications in order to reduce the size of each device. To this end, many design algorithms have been introduced such as Remez exchange, linear programming, and …

    ucf Repository record for Finite impulse response utilizing the principles of superposition (opens in a new tab)

  19. Fourier-based design of acoustic transducers

    … work presented in this thesis investigates novel transducer implementations that take advantage of directional sensing and generation of acoustic waves. These transducers are conceived by exploiting a Fourier-based design methodology. The proposed devices find application in the broad field of …

    gatech Repository record for Fourier-based design of acoustic transducers (opens in a new tab)

Page 1 of 3