  1. Development of a flat frequency response pressure transducer system.

    … frequency response of a cascaded remote pressure transducer system has been developed. This prediction was used to find a theoretical configuration which would produce a fairly flat frequency response (1.00 ± 0.05) over a 100 hertz range. Such a configuration would allow cross -correlation of an …

    nps Repository record for Development of a flat frequency response pressure transducer system. (opens in a new tab)

  2. Development of a novel cell traction force transducer based on cholesteryl ester liquid crystals. Characterisation, quantification and evaluation of a cholesteryl ester liquid crystal based single cell force transducer system.

    … rates. A newly developed cell traction force transducer system based on cholesteryl ester lyotropic liquid crystals (LCTFT) was developed to sense localised traction forces of human keratinocyte cell lines (HaCaTs), in which the length of the deformation line induced represents the intensity …

    bradford Repository record for Development of a novel cell traction force transducer based on cholesteryl ester liquid crystals. Characterisation, quantification and evaluation of a cholesteryl ester liquid crystal based single cell force transducer system. (opens in a new tab)

  3. A sensor interface system for digital radiosondes

    … integrated circuits, and a silicon pressure transducer. System tests conducted under environmental conditions indicate satisfactory results.

    nps Repository record for A sensor interface system for digital radiosondes (opens in a new tab)

  4. A Procedure for the Measurement of Glosso-Maxillary Forces

    … forces at four palatal loci using an electronic transducer system described by Lear et, al. (1965). Of particular interest was the development of a convenient and accurate calibration device for both intraoral and extraoral application. A further object of interest was the effect an acrylic …

    loma-linda Repository record for A Procedure for the Measurement of Glosso-Maxillary Forces (opens in a new tab)

  5. Design and Analysis of Capacitive Parametric Ultrasound Transducers for Wireless Power Transfer

    … devices, a capacitive parametric ultrasound transducer system is analyzed and improved upon. While 1D modeling had sufficed for proof of concept and power transfer with low efficiency has been demonstrated, a more detailed model gives insight to behavior that were previously overlooked. …

    gatech Repository record for Design and Analysis of Capacitive Parametric Ultrasound Transducers for Wireless Power Transfer (opens in a new tab)

  6. Automated angular scans to determine flaw orientation for use in model-based flaw reconstruction

    … scattering, an automated multiviewing ultrasonic transducer system and associated software has been designed and built in order to perform characterization and analysis of volumetric flaws. The flaw is characterized by its size, shape, and orientation within a material. Utilizing inverse …

    iastate Repository record for Automated angular scans to determine flaw orientation for use in model-based flaw reconstruction (opens in a new tab)

  7. Bodenspannungen und Deformationen in Waldböden durch Ernteverfahren

    … Deformationsmessung (kombiniertes Stress State Transducer (SST) und Displacement Transducer System (DTS)) unter realen Erntebedingungen wurden die Folgen des Fahrzeugeinsatzes im Bestand belegt. Die Spannungsmessungen in verschiedenen Bodentiefen zeigen die Notwendigkeit, Bodenspannungen und …

    cau-kiel Repository record for Bodenspannungen und Deformationen in Waldböden durch Ernteverfahren (opens in a new tab)

  8. Quantitative analysis of oral phase dysphagia

    … A computer-aided tongue force measurement system has been developed that is capable of quantifying individual tongue strength and coordination. This strain gauge-based transducer system measures upward and lateral tongue thrust levels during a "non-swallowing" test condition. Clinical …

    ubc Repository record for Quantitative analysis of oral phase dysphagia (opens in a new tab) Download PDF for Quantitative analysis of oral phase dysphagia (opens in a new tab)

  9. Simulation and control of thickness-mode Piezoelectric transducers

    A new general three-port systems model of the thickness-mode piezoelectric transducer is proposed. This model is considered to have several substantial advantages over existing modelling techniques. In particular, it may be readily used to explain the underlying physical operation of ultrasonic …

    strathclyde Repository record for Simulation and control of thickness-mode Piezoelectric transducers (opens in a new tab)

  10. Studies of some acoustic resonant systems

    … the mechanical properties of an electro-acoustic transducer with an impedance well matched to liquids are measured. The transducer consists of neoprene sandwiched between two conducting plates. The displacement of the transducer under different driving conditions has been measured usng an …

    ubc Repository record for Studies of some acoustic resonant systems (opens in a new tab) Download PDF for Studies of some acoustic resonant systems (opens in a new tab)

  11. Development and application of a technique for evaluating root zone drainage

    … understanding of the water balance of forest ecosystems is of benefit to foresters who manage second rotation stands. Maximizing the mean annual increment can be better realized if recognition is given to the importance of the water balance. One component of the water balance, root zone drainage, …

    ubc Repository record for Development and application of a technique for evaluating root zone drainage (opens in a new tab) Download PDF for Development and application of a technique for evaluating root zone drainage (opens in a new tab)

  12. Validity and reliability of accelerometers for examining vertical jump performance

    … compared to a force platform + linear position transducer system. The data from the accelerometer were then resampled to determine the optimum sampling frequency. Reliability was assessed by intraclass correlation (ICC) and coefficient of variance (CV). Validity was evaluated by a linear …

    wvu Repository record for Validity and reliability of accelerometers for examining vertical jump performance (opens in a new tab)

  13. Acoustooptical techniques for ultrasonic materials evaluation: optical fiber interferometry and pulse-echo systems

    The performance of two acoustooptical systems for ultrasonic materials characterization has been investigated. The first system uses an optical fiber interferometric technique to detect directly slowly varying residual stresses and both high frequency continuous and transient ultrasonic waves …

    vt Repository record for Acoustooptical techniques for ultrasonic materials evaluation: optical fiber interferometry and pulse-echo systems (opens in a new tab)

  14. Microbubble Generation By Piezoelectric Transducers For Biomedical Studies

    … To better understand the bubble mechanism, a system needs to be constructed which allows clear differentiation on the impact of bubbles from that of shocks. Such a generator needs to be low profile in order to place under a microscope. A piezoelectric transducer system was designed to meet the …

    odu Repository record for Microbubble Generation By Piezoelectric Transducers For Biomedical Studies (opens in a new tab)

  15. Two-dimensional transient flow in non-level irrigation basins.

    … were measured with a double-bubbler and pressure transducer system. The same field conditions were simulated using the two-dimensional implicit zero-inertia model, and the results compared favorably. The two-dimensional implicit zero-inertia model has great potential to simulate fields with any …

    arizona-thes Repository record for Two-dimensional transient flow in non-level irrigation basins. (opens in a new tab)

  16. Capacitive Micromachined Ultrasonic Transducers for Non-destructive Testing Applications

    … defects in the object. Traditionally, ultrasonic transducers for NDT are made with piezoelectric crystals. Meanwhile, another class of ultrasonic transducers known as capacitive micromachined ultrasonic transducers (CMUTs) have become popular in medical ultrasound research because of their large …

    waterloo Repository record for Capacitive Micromachined Ultrasonic Transducers for Non-destructive Testing Applications (opens in a new tab)

  17. Rotary nonresonant energy harvesting

    The aim of this dissertation was to develop a system for a nonresonant rotary energy harvester, which converts a fraction of rotational mechanical energy into electrical energy. With this energy, won from an extremely wide range of mechanical rotational speeds (from a few hundredths to 6000 …

    freiburg-diss Repository record for Rotary nonresonant energy harvesting (opens in a new tab)

  18. Development of an annular array through-transmission system for non-contact inspection applications

    … used to efficiently transfer energy between the transducer and the sample under investigation. There are some materials which are not suitable for liquid coupling, either through material properties or the complexity of the surface geometry. The alternative of using an air-coupled approach is …

    strathclyde Repository record for Development of an annular array through-transmission system for non-contact inspection applications (opens in a new tab)

  19. Dynamic Loading of Soil-Cement for Flexible Pavement Design

    … measurement have been investigated, and a transducer system of high accuracy LVDT's developed. This system can meet most of the testing requirements such as reliability, accuracy at high frequency, ease of preparation and assembling.<br/><br/>The finite element method was used to analyse …

    southwales Repository record for Dynamic Loading of Soil-Cement for Flexible Pavement Design (opens in a new tab) Download PDF for Dynamic Loading of Soil-Cement for Flexible Pavement Design (opens in a new tab)

  20. Cyclic nucleotide signalling in cardiac myocytes from the mdx model of Duchenne muscular dystrophy

    … The IonOptix contractility and force transducer system were used to explore the contractile performance and force generation upon contraction in mdx adult cardiomyocytes.</p> <p><b>Results:</b> cAMP and cGMP regulation and compartmentalisation seem to be significantly altered in mdx …

    oxford Repository record for Cyclic nucleotide signalling in cardiac myocytes from the mdx model of Duchenne muscular dystrophy (opens in a new tab)