Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 73 for “"Transfer Length"”.

  1. Evaluation of Prestress Losses, Transfer Length and Harping Characteristics of CFRP Systems

    … CFRP systems in bridge beams. Prestress losses, transfer length, and harping characteristics of CFRP systems were evaluated in this study as critical parameters, which affect the design and long-term behavior of CFRP prestressed concrete bridge beams. This dissertation aims at evaluating …

    houston Repository record for Evaluation of Prestress Losses, Transfer Length and Harping Characteristics of CFRP Systems (opens in a new tab)

  2. An investigation of the variables affecting the transfer length of prestressed concrete members

    <p>The transfer length of pretensioned/prestressed concrete members is a function of several variables. This study is an attempt to establish relationships between these variables and the transfer length. Reviews of the existing studies on transfer and development length are also included.</p> …

    ut-knoxville Repository record for An investigation of the variables affecting the transfer length of prestressed concrete members (opens in a new tab)

  3. In-Service Behaviour of Reinforced Concrete based on a Variable Transfer Length Model

    … focusing on the important concept of the transfer length and its role in the deformation and cracking of concrete structures. The transfer length represents the distance from the face of a crack over which bond stresses at the reinforcement-concrete interface act to restore a condition of …

    unsw Repository record for In-Service Behaviour of Reinforced Concrete based on a Variable Transfer Length Model (opens in a new tab)

  4. A Test Method for the Transfer Length of Prestressing Strand in Hollow Core Slabs

    A method for measuring the transfer length of prestressing strand in HCS using a distributed strain sensor (DSS) was proposed. This DSS consists of a strip of material with strain gauges pre-attached to it. The DSS can then be attached to the HCS to measure strain when the strands are released. A …

    umn Repository record for A Test Method for the Transfer Length of Prestressing Strand in Hollow Core Slabs (opens in a new tab)

  5. An analysis of the methodologies utilized in determining the transfer length of prestressed concrete members

    … the current methods that are used to determine transfer length. The goal of this study was to quantitatively define some of the many variables that affect transfer length measurement. The variables that were investigated in this study are gage length, gage spacing, strain gage sensitivity, …

    ut-knoxville Repository record for An analysis of the methodologies utilized in determining the transfer length of prestressed concrete members (opens in a new tab)

  6. Transfer Length, Development Length, Flexural Strength, and Prestress Loss Evaluation in Pretensioned Self-Consolidating Concrete Members

    … concrete versus normal concrete on transfer and development lengths, and flexural strengths of prestressed members. Three small rectangular members were made, two cast with SCC mixes and one cast with a conventional mix, to determine the transfer length of each mix. Transfer lengths …

    vt Repository record for Transfer Length, Development Length, Flexural Strength, and Prestress Loss Evaluation in Pretensioned Self-Consolidating Concrete Members (opens in a new tab)

  7. Investigation of Transfer Length, Development Length, Flexural Strength and Prestress Loss Trend in Fully Bonded High Strength Lightweight Prestressed Girders

    … about by the reduction of dead loads in bridges. Transfer Length measurements conducted on two AASHTO Type IV HSLWC prestressed girders, resulted in an average transfer length of 17 inches, well below the AASHTO and ACI guidance. Two girders composed of HSLWC AASHTO Type II girders and a 48" x 8" …

    vt Repository record for Investigation of Transfer Length, Development Length, Flexural Strength and Prestress Loss Trend in Fully Bonded High Strength Lightweight Prestressed Girders (opens in a new tab)

  8. Grade 300 Prestressing Strand and the Effect of Vertical Casting Position

    … the effect the as-cast vertical location had on transfer length, development length, and flexural strength and to resolve the discrepancies regarding the definition of the top-bar/strand effect. Two types of test specimens were fabricated and tested investigating each respective item. The …

    vt Repository record for Grade 300 Prestressing Strand and the Effect of Vertical Casting Position (opens in a new tab)

  9. Development length of prestressing strand

    … 318-83 Building Code Requirements on development length of prestressing strands, a major experimental research on bond development of seven-wire prestresssing strands was conducted. Twenty-two full-scale AASHTO Type-I prestressed concrete bridge beams were tested for transfer length and strand end …

    utk-theses Repository record for Development length of prestressing strand (opens in a new tab)

  10. Measurement of Transfer and Development Lengths of 0.7 in. Strands on Pretensioned Concrete Elements

    … for the slow utilization. This study measured transfer and development length, and evaluated applicable strand spacing of 0.7 in. (17.8 mm) prestressing strands for 24 pretensioned concrete beams. Each beam contained one prestressing strand or two prestressing strands placed at spacing of 2.0 …

    arkansas Repository record for Measurement of Transfer and Development Lengths of 0.7 in. Strands on Pretensioned Concrete Elements (opens in a new tab)

  11. Long-term behaviour of GFRP prestressed concrete beams

    … and Baquero (2010). This study investigated the transfer length of the prestressed GFRP bars of diameters 12 mm and 16 mm in concrete. Most of the available research studied the transfer length of CFRP and AFRP tendons, and both CAN/CSA-S6-06 and ACI 440.1R-06 give equations for predicting the …

    waterloo Repository record for Long-term behaviour of GFRP prestressed concrete beams (opens in a new tab)

  12. Influence of Concrete Compressive Strength on Transfer and Development Lengths of Prestressed Concrete

    … Strand bond is assessed by measuring the transfer length and development length for prestressed beams cast in the laboratory. In the U.S., strand bond is predicted using transfer length and development length equations provided by the American Concrete Institute (ACI-318) Building Code and …

    arkansas Repository record for Influence of Concrete Compressive Strength on Transfer and Development Lengths of Prestressed Concrete (opens in a new tab)

  13. Evaluation of high strength lightweight concrete precast, prestressed bridge girders

    … The BT-54 girders were 107 ft 11½ inches in length. The prestressing strands used in these girders were 0.6 in diameter, grade 270, low relaxation strands. Material properties and member properties were tested. All 5 girders of span 2 were instrumented with vibrating wire strain gages at …

    gatech Repository record for Evaluation of high strength lightweight concrete precast, prestressed bridge girders (opens in a new tab)

  14. Structural Evaluation of Prestressed Self-Consolidating Concrete Bridge Girders Using Limestone Aggregates

    … girders were fabricated and tested to evaluate transfer length, prestress losses, camber, flexural behavior and strength, flexural rigidity, and shear strength. Two of the girders were cast with SCC and one was cast with conventional concrete to serve as a control specimen. Each girder was …

    sdstate Repository record for Structural Evaluation of Prestressed Self-Consolidating Concrete Bridge Girders Using Limestone Aggregates (opens in a new tab)

  15. Bond Performance of High-Capacity Strands in High Strength Concrete

    … was conducted to analyze the factors affecting transfer length. With the comparison of the non-pretensioned and pretensioned pull-out tests, the contribution of each bond mechanism was quantitatively analyzed. The tests indicated that the bond performance was dependent on the specimen length and …

    utk-theses Repository record for Bond Performance of High-Capacity Strands in High Strength Concrete (opens in a new tab)

  16. Effect of Transmission Line Measurement (TLM) Geometry on Specific Contact Resistivity Determination

    … of the order of 10^{-5} to 10^{-2} Ohm-cm^2. The transfer length or L_T which is the characteristic length that the charge carriers travel beneath the contact before flowing up into the contact. It has also been seen that in certain cases of TLM device dimensions, the extracted L_T is greater than …

    rit Repository record for Effect of Transmission Line Measurement (TLM) Geometry on Specific Contact Resistivity Determination (opens in a new tab)

  17. Structural Performance of High Strength Lightweight Concrete Pretensioned Bridge Girders

    … whether current bridge design specifications for transfer length, development length, prestress loss, camber, and flexural capacity are satisfactory for use with fully-bonded, pretensioned flexural members consisting of HSLWC and to make recommendations for improvements where necessary. Twelve …

    vt Repository record for Structural Performance of High Strength Lightweight Concrete Pretensioned Bridge Girders (opens in a new tab)

  18. Beyond Conventional Impurity Doping: Direct Modulation Doping for Enhanced Carrier Transport in Nanoscale Silicon

    … test structures such as Hall-bars and the transfer length method structures are used to investigate the electronic transport properties of modulation doped silicon and demonstrate its benefits over classical doping approaches. To this end, silicon nanowires were initially provided with …

    qucosa-diss

  19. Behavioral Study of Ultra High Performance Concrete Girders

    … term properties such as early age shrinkage, transfer length, creep behavior and shrinkage under steam treatment. Data has been recorded through vibrating wire gages installed at strategic locations within each girder before they are cast. While the shrinkage and creep observed are very low …

    maryland Repository record for Behavioral Study of Ultra High Performance Concrete Girders (opens in a new tab)

Page 1 of 4