Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 26 for “"Transfer lengths"”
-
Determining the transfer length in prestressed concrete railroad ties produced in the United States
This thesis presents results from transfer length measurements on prestressed concrete railroad ties. Results are shown from the four main producers of concrete ties in the United States. Six prestressed concrete tie plants were visited by the research team to measure transfer length on ties with …
-
Assessing the Bond Quality of Prestressing Strands Using Nasp Bond Test
In prestressed concrete, effective transfer of the prestressing force to the surrounding concrete is essential to achieve the strength and integrity within the structure. Bonding of the prestressing strands with concrete has been of concern to engineers for years. This research conducted an …
-
A comprehensive study of prestressing steel and concrete variables affecting transfer length in pre-tensioned concrete crossties
… was conducted to determine the variation in transfer length of pre-tensioned prestressed concrete railroad ties with different parameters, including prestressing steel type and concrete variables. The in-depth evaluation included different prestressing reinforcement types that are employed in …
-
Top Strand Effect and Evaluation of Effective Prestress in Prestressed Concrete Beams
… The "top strand effect" was evaluated through transfer and development length tests of prestressed concrete beams. Eight beams were cast with normal orientation, while four beams were cast with inverted orientation so that a significant depth of fresh concrete was placed below prestressing …
-
Evaluation of indented prestressing wires for KDOT bridge members
… of a test plan, the determination of the transfer lengths, loading the specimens to failure, and analysis of the data collected. This purpose of this research was to investigate opportunities to utilize indented prestressing wires in KDOT bridge members to optimize designs to be more …
-
Bond Strength of Mild Steel in Polypropylene Fiber Reinforced Concrete (PFRC)
… reinforcement has been carried out. Two fiber lengths, four fiber contents and two different water to cement ratios were used in this study. Differences in bond stress versus bond slip behavior due to the above variations were investigated using ASTM Standard Test Method C 234 - 71. A second …
-
Evaluating the time-dependent deformations and bond characteristics of a self-consolidating concrete mix and the implication for pretensioned[sic] bridge applications
… specimens that were tested to evaluate their transfer and development lengths. These specimens included both single-strand and multiple-strand beams, as well as specimens designed to evaluate the so-called “top-strand" effect. The top-strand specimens, with more than 20 inches of concrete …
-
Development of a portable optical strain sensor with applications to diagnostic testing of prestressed concrete
The current experimental method to determine the transfer length in prestressed concrete members consists of measuring concrete surface strains before and after de-tensioning with a mechanical strain gage. The method is prone to significant human errors and inaccuracies. In addition, since it is a …
-
Development length of prestressing strand
… concrete bridge beams were tested for transfer length and strand end slip at transfer and for development length in static destructive tests. Additionally, transfer length in prestressed concrete prisms and pullout behavior of non-prestressed strands in concrete prisms were obtained. A …
-
Transfer Length, Development Length, Flexural Strength, and Prestress Loss Evaluation in Pretensioned Self-Consolidating Concrete Members
… concrete versus normal concrete on transfer and development lengths, and flexural strengths of prestressed members. Three small rectangular members were made, two cast with SCC mixes and one cast with a conventional mix, to determine the transfer length of each mix. Transfer lengths …
-
Grade 300 Prestressing Strand and the Effect of Vertical Casting Position
… the effect the as-cast vertical location had on transfer length, development length, and flexural strength and to resolve the discrepancies regarding the definition of the top-bar/strand effect. Two types of test specimens were fabricated and tested investigating each respective item. The …
-
Determining the bond characteristics of 7.5-mm and 7.8-mm prestressing wires
… 6”x10” beams were cast for each type of wire at lengths of 5.5-ft, 6.5-ft, and 7.5-ft. The Type III concrete mixture used was kept constant throughout the study to investigate the effects of the wire profile and concrete release strength on bond behavior. During beam fabrication, prestressing …
-
Effects of Curing Time and Curing Temperature on the Standard Test for Strand Bond
… concrete and to correlate bond performance to transfer lengths and development lengths in prestressed members. The study focused on altering the curing time and temperature, while maintaining the required mortar strength as specified by the STSB method. Curing conditions lacking in …
-
Behavior of Larger-Diameter Strands in the Disturbed Region of Prestressed Concrete Girders
… shipping limit.</em></p> <p><em>Development and transfer lengths for larger diameter strands were found to be much shorter than current models predict. A methodology is proposed for the determination of development length for any size strand. In this study, the effectiveness of casting strand …
-
Large-Scale Optical Hardware for Neural Network Inference Acceleration
… could reduce energy consumption for long data transfer lengths, but not in tightly packed electronic multiplier arrays. Therefore, in a second project, we expanded upon this work by performing reconfigurable optical multicast and analog optoelectronic weighting to compute DNN layer outputs in a …
-
Investigating the Bond of Prestressing Strands in Lightweight Self-Consolidating Concrete
… the 1950s. Limited data are available on the transfer and development length of strands cast in SCC and even less for strands cast in LWSCC. The differences in material properties resulting from the lightweight coarse aggregate and mix proportioning used for LWSCC have potential to lead to …
-
Measurement of Transfer and Development Lengths of 0.7 in. Strands on Pretensioned Concrete Elements
… for the slow utilization. This study measured transfer and development length, and evaluated applicable strand spacing of 0.7 in. (17.8 mm) prestressing strands for 24 pretensioned concrete beams. Each beam contained one prestressing strand or two prestressing strands placed at spacing of 2.0 …
-
Raman Spectroscopic Stress Analysis of Carbon Fibre Composites in Compression
… highlighted improved interfacial shear stress transfer efficiency and reduced transfer lengths with functionalised SWCNT coatings. These coatings doubled interfacial shear stress (IFSS) in some cases but introduced localised stress variations and additional non-linearity …
-
Evaluation of prestressing strand bond with Type IL cement
… This study investigates the bond behavior and transfer length of prestressing strands embedded in grout, mortar, and concrete made with five different cementitious systems: Type I/II cement, Type IL cement (containing 8% limestone inter-ground with Type I/II clinker), and intermixed Type IL …
Page 1 of 2