Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Transformer Protection"”.

  1. Transformer protection based on dynamic state estimation

    … objective of the proposed research is to detect transformer internal faults or transformer overheating and trip the transformer, with immunity to external faults for which tripping of the transformer is not required. A new transformer protection scheme based on dynamic state estimation has been …

    gatech Repository record for Transformer protection based on dynamic state estimation (opens in a new tab)

  2. The application of artificial neural networks to transformer protection

    … magnetizing inrush currents that may occur in transformers is developed in this thesis. It is based on the fact that the magnetizing inrush current has large harmonic components. A feed-forward neural network (FFNN) has been trained using the back-propagation algorithm, to discriminate between …

    ubc Repository record for The application of artificial neural networks to transformer protection (opens in a new tab) Download PDF for The application of artificial neural networks to transformer protection (opens in a new tab)

  3. Dynamic transformer protection a novel approach using state estimation

    Transformers are very important parts of any electrical network, and their size increase so does their price. Protecting these important devices is a daunting task due to the wide variety of operating conditions. This thesis develops a new protection scheme based on state estimation.The foundation …

    gatech Repository record for Dynamic transformer protection a novel approach using state estimation (opens in a new tab)

  4. Ratios-Based Universal Differential Protection Scheme for Power Transformers

    Power transformers are one of the most important and costly components in power systems. It is subject to short circuit faults similar to any other component of the power system. Failure to detect these faults may result in transformer blaze and may subsequently lead to property damage. Therefore, …

    calgary Repository record for Ratios-Based Universal Differential Protection Scheme for Power Transformers (opens in a new tab)

  5. Validation of Results of Smart Grid Protection through Self-Healing

    … is a verification of the results of “Smart Grid Protection through Self-Healing” from the publication of Chathurika Chandraratne, et al., that proposes a protection solution for the smart grid. The paper used as reference has as the main focus on three different protections; directional …

    usf Repository record for Validation of Results of Smart Grid Protection through Self-Healing (opens in a new tab)

  6. Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda

    The differential function is widely used in power transformer protection, leading to a reliable discrimination between internal faults and other events associated with power transformer operation. However, the conventional differential protection function based on the estimation of current phasors …

    brazil-ufrn Repository record for Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda (opens in a new tab)

  7. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    During the course of a transformer's operational life, it experiences many challenges to its insulation. Chemical stresses, such as moisture in insulating oil, deteriorate insulation chemically. Mechanical stresses and thermal stresses, such as those experienced during a large external fault, also …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  8. Fault Detection of HVDC Transformer Windings using Impedance Protection

    Power transformers play a key role in high voltage direct current (HVDC) systems to overcome the limitations of conventional AC transmission and are expensive and fundamental components in power systems. Transformer winding faults are among the most frequent issues in transformers. Since winding …

    chalmers Repository record for Fault Detection of HVDC Transformer Windings using Impedance Protection (opens in a new tab)

  9. Security Enhancement of Power Transformer Differential Protection

    … of faults for each architecture for IEC 61850 transformer protection relays. Next, an adversarial training method is proposed to enhance the security of the models. The performance of the models before and after adversarial training is compared. The results are used to propose the best model …

    toronto-retro Repository record for Security Enhancement of Power Transformer Differential Protection (opens in a new tab)

  10. Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson.

    Transformer protection is one of the most challenging applications within the power system protective relay field. Transformers with a capacity rating exceeding 10 MVA are usually protected using differential current relays. Transformers are an aging and vulnerable bottleneck in the present power …

    mtu Repository record for Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson. (opens in a new tab)

  11. A wavelet-based restricted earth-fault power transformer differential protection

    In order to enhance power transformer differential protection, especially with respect to its reliability and speed, several schemes have been proposed in the last years. Faults inside the transformer protection zone may cause critical damages to this device if its protection unit does not operate. …

    brazil-ufrn Repository record for A wavelet-based restricted earth-fault power transformer differential protection (opens in a new tab)

  12. Hybrid Smart Transformer for Enhanced Power System Protection Against DC With Advanced Grid Support

    … and strategic equipment in the substation is the transformer and is expected to perform a variety of functions beyond mere voltage conversion and isolation. While the concept of smart solid-state transformers (SSTs) is being widely recognized, their respective lifetime and reliability raise …

    clemson Repository record for Hybrid Smart Transformer for Enhanced Power System Protection Against DC With Advanced Grid Support (opens in a new tab)

  13. ATP modeling of internal transformer faults for relay performance testing

    Transformers are very important elements of any power system. Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient …

    mtu Repository record for ATP modeling of internal transformer faults for relay performance testing (opens in a new tab)

  14. Harmonic emissions in electric vehicle smart charging

    … loading on the aging of distribution transformers is quantified. A thermal-electrical model based on IEEE C57.91 and IEEE C57.110 standards is applied to a 160 kVA distribution transformer evaluated under full-load conditions, which are achieved by varying the number of simultaneously …

    strathclyde Repository record for Harmonic emissions in electric vehicle smart charging (opens in a new tab)

  15. Turn-to-turn fault detection in transformers using negative sequence currents

    A power transformer is one of the most important and expensive components in any power system. Power transformers can be exposed to a wide variety of abnormal conditions and faults. Internal turn-to-turn faults are the most difficult types of faults to detect within the power transformer. The IEEE …

    sask Repository record for Turn-to-turn fault detection in transformers using negative sequence currents (opens in a new tab)

  16. IMPACT OF INRUSH CURRENTS AND GEOMAGNETICALLY INDUCED CURRENTS ON TRANSFORMER BEHAVIOR

    Transformers are the tie-points of electrical power systems. Their protection from power system faults and other innate issues is of prime importance. A few of the issues that are studied in this report are magnetic inrush currents, geomagnetically induced currents in power transformers and …

    mtu Repository record for IMPACT OF INRUSH CURRENTS AND GEOMAGNETICALLY INDUCED CURRENTS ON TRANSFORMER BEHAVIOR (opens in a new tab)

  17. Chránění transformátoru rozdílovou ochranou

    Bakalářská práce se zabývá problematikou chránění výkonového transformátoru a podrobněji se zaměřuje na ochranu rozdílovou. Vysvětluje její princip a blíže seznamuje s nastavením vypínací charakteristiky, přičemž je uveden celý postup jejího výpočtu. Na přístrojích SPAD 346 C a REF542plus, které …

    brno-tech Repository record for Chránění transformátoru rozdílovou ochranou (opens in a new tab)

  18. Testování ochrany transformátoru

    Hlavnou témou bakalárskej práce bola ochrana transformátora, konkrétne rozdielová ochrana transformátora. Princíp jej funkcie, stabilizácia a vypínacia charakteristika. Bola navrhnutá metodika testovania modulu SPCD 3D53 diferenciálnej stabilizovanej ochrany SPAD 346C od firmy ABB. Nastavenie …

    brno-tech Repository record for Testování ochrany transformátoru (opens in a new tab)

  19. Návrh transformační stanice pro vyvedení výkonu z kogenerační jednotky

    Diplomová práca sa zaoberá problematikou návrhu transformačnej stanice pre vyvedenie výkonu z kogeneračnej jednotky o elektrickom výkone do 1 MW. V práci je vypracovaný postup navrhovania jednotlivých zariadení ako je transformátor s menovitým prevodom 22/0,4 kV, rozvádzač VN a rozvádzač NN. Pri …

    brno-tech Repository record for Návrh transformační stanice pro vyvedení výkonu z kogenerační jednotky (opens in a new tab)