Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Transformer bushing"”.

  1. Seismic response of transformer bushing systems and their rehabilitation using frictional pendulum system

    … concerned with the performance of electric power transformers and their attachments under earthquake loading. It begins with the description of the transformers, attached bushings, and some typical examples of substation failures in earthquake loading. This is followed by the development of finite …

    njit Repository record for Seismic response of transformer bushing systems and their rehabilitation using frictional pendulum system (opens in a new tab)

  2. Risk-Based Performance Assessment of a Seismic Retrofit Technique for Medium- and High-Voltage Transformer Bushing Systems

    High voltage electrical transformers bushing systems have exhibited vulnerability during past earthquakes. The enhanced performance of bushings mounted on rigid base observed during shake table testing does not correlate well with their performance in the field. It is suspected that the seismic …

    tamu Repository record for Risk-Based Performance Assessment of a Seismic Retrofit Technique for Medium- and High-Voltage Transformer Bushing Systems (opens in a new tab)

  3. Issues of seismic response and retrofit for critical substation equipment

    … on means to reduce the seismic hazard for transformer-bushing systems and different issues of the response and rehabilitation of transformers. The primary means of seismic mitigation investigated is the use of the Friction Pendulum System (FPS) bearings to seismically isolate transformers. …

    njit Repository record for Issues of seismic response and retrofit for critical substation equipment (opens in a new tab)

  4. CRACK PATTERN SIMULATION OF PRESSURIZED BOROSILICATE GLASS TUBE UNDER PELLET IMPACT USING ALE METHOD

    Transformer bushings are a common target for sniper attacks to cause power failure in large areas. Given the size, internal pressure and brittle nature of transformer bushing, pellet impact causes damage to surrounding components due to broken bushing pieces. To mitigate this, a project was …

    mtu Repository record for CRACK PATTERN SIMULATION OF PRESSURIZED BOROSILICATE GLASS TUBE UNDER PELLET IMPACT USING ALE METHOD (opens in a new tab)

  5. Simulations of Dielectric Frequency Response of Bushings for a Non-Destructive On-site Defect Identification

    Bushings are integrated components of high voltage transformers providing connections of windings to external circuits outside the transformer shell while providing mechanical and insulation support. During normal operation, bushings are consistently influenced by operating voltage, load current, …

    chalmers Repository record for Simulations of Dielectric Frequency Response of Bushings for a Non-Destructive On-site Defect Identification (opens in a new tab)

  6. Winding movement and condition monitoring of power transformers in service

    Power transformers are the most expensive pieces of equipment in a power substation. It is very important to prevent failures and detect problems in a transformer as early as possible. This thesis reviews the diagnostic and monitoring tests and equipment available to assess the condition of …

    ubc Repository record for Winding movement and condition monitoring of power transformers in service (opens in a new tab) Download PDF for Winding movement and condition monitoring of power transformers in service (opens in a new tab)

  7. Partial discharge monitoring of power transformers

    … of partial </span>discharges within power transformers, including the classification and recognition of partial <span style='letter-spacing:-.25pt'>discharge signals in the both frequency and time domains from bushing tap points via </span><span style='letter-spacing:-.35pt'>RFCT (Radio …

    soton Download PDF for Partial discharge monitoring of power transformers (opens in a new tab)

  8. Protection of High-Voltage Transformer Bushings and Other Brittle Structures Against Impact

    … impact behavior of porcelain high-voltage (HV) transformer bushings under high-velocity impact, with a focus on their protection with feasible methods which could be quickly applied in service to prevent vandalism and other undesirable impact situations. The bushings are brittle and pressurized; …

    denver Repository record for Protection of High-Voltage Transformer Bushings and Other Brittle Structures Against Impact (opens in a new tab)

  9. Výpočet ztrát a oteplení víka olejového transformátoru v blízkosti průchodek

    Tato bakalářská práce se zabývá výpočtem ztrát na víku olejového transformátoru v blízkosti NN průchodek. Dochází zde totiž k tepelnému namáhání a stárnutí těsnění pod průchodkou a následně k úniku oleje. Je zde stručně popsána výroba dílčích částí olejového transformátoru a kapitola věnována …

    brno-tech Repository record for Výpočet ztrát a oteplení víka olejového transformátoru v blízkosti průchodek (opens in a new tab)