Showing 1 to 12 of 12 for “"Transformer differential protection"”.

  1. Security Enhancement of Power Transformer Differential Protection

    … of faults for each architecture for IEC 61850 transformer protection relays. Next, an adversarial training method is proposed to enhance the security of the models. The performance of the models before and after adversarial training is compared. The results are used to propose the best model …

    toronto-retro Repository record for Security Enhancement of Power Transformer Differential Protection (opens in a new tab)

  2. Transformer Differential Protection Under Geomagnetically Induced Current Conditions

    … induced currents (GICs) flow through the power transformers with grounded neutrals. The transformers subjected to the GIC experience part-cycle core saturation creating significant magnetizing current harmonics, including dominant second harmonics. The GIC-caused harmonics can pose issues for …

    york Repository record for Transformer Differential Protection Under Geomagnetically Induced Current Conditions (opens in a new tab)

  3. A wavelet-based restricted earth-fault power transformer differential protection

    In order to enhance power transformer differential protection, especially with respect to its reliability and speed, several schemes have been proposed in the last years. Faults inside the transformer protection zone may cause critical damages to this device if its protection unit does not operate. …

    brazil-ufrn Repository record for A wavelet-based restricted earth-fault power transformer differential protection (opens in a new tab)

  4. Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson.

    Transformer protection is one of the most challenging applications within the power system protective relay field. Transformers with a capacity rating exceeding 10 MVA are usually protected using differential current relays. Transformers are an aging and vulnerable bottleneck in the present power …

    mtu Repository record for Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson. (opens in a new tab)

  5. Differential Protection for Arbitrary Three-Phase Power Transformers

    … how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard …

    lund Repository record for Differential Protection for Arbitrary Three-Phase Power Transformers (opens in a new tab) Download PDF for Differential Protection for Arbitrary Three-Phase Power Transformers (opens in a new tab)

  6. Performance Optimization of the Differential Protection Schemes

    Current differential protection principle is superior in terms of sensitivity and speed of operation in comparison with other protection principle used in power systems. From the last five decades, various current differential protection schemes are widely used to protect busbars, transformers, and …

    uno Repository record for Performance Optimization of the Differential Protection Schemes (opens in a new tab)

  7. Protection system representation in the Electromagnetic Transients Program

    … the addition of the few critical elements of a protection system to the Electromagnetic Transients Program (EMTP). The EMTP is one of the most widely used programs for the simulation of transients in power systems. The EMTP contains models for almost every major power system component. A …

    vt Repository record for Protection system representation in the Electromagnetic Transients Program (opens in a new tab)

  8. Modeling relays for power system protection studies

    … relays is important to adjust and settle protection equipment in electrical facilities and to train protection personnel. Designing of numerical relays is employed to produce new prototypes and protection algorithms. Computer models of numerical relays for the study of protection systems …

    sask Repository record for Modeling relays for power system protection studies (opens in a new tab)

  9. Intelligent technique based digital differential protection for generator-transformer unit

    The requirement of digital differential protection has become more and more severe with the increasing capacity of Generator-Transformer unit and the development of power industry. An advanced principle, its application and perspective of differential protection are developed in this thesis. …

    city-london Download PDF for Intelligent technique based digital differential protection for generator-transformer unit (opens in a new tab)

  10. Transient Simulations of Power Systems with Inverter Interfaced Resources

    … to occur only with lightly loaded distribution transformers. The residential solar generation is connected to the secondary of a single-phase distribution transformer. The transformer's loading is thereby hypothesized to be influenced by the power generated by the solar panel and the power …

    mtu Repository record for Transient Simulations of Power Systems with Inverter Interfaced Resources (opens in a new tab)

  11. Proteção diferencial adaptativa de transformadores de potência baseada na análise de componentes wavelets

    Este trabalho fundamenta-se no desenvolvimento e aprimoramento de uma metodologia de proteção diferencial de Transformadores de Potência. A metodologia desenvolvida avalia eventos transitórios que dificultam a operação correta de relés diferenciais aplicados à proteção de transformadores. O estudo …

    brazil-ufrgs Repository record for Proteção diferencial adaptativa de transformadores de potência baseada na análise de componentes wavelets (opens in a new tab)

  12. Proteção diferencial de transformadores trifásicos utilizando a transformada wavelet

    A qualidade e a continuidade do fornecimento de energia elétrica aos consumidores são fatores muito importantes quando da avaliação da eficiência de um sistema elétrico de potência. Nesse contexto, os transformadores são equipamentos muito importantes e demandam especial atenção quando do projeto …

    brazil-ufrgs Repository record for Proteção diferencial de transformadores trifásicos utilizando a transformada wavelet (opens in a new tab)