Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Transformer saturation"”.

  1. A microprocessor based bus relay

    … new technique to overcome the problem of current transformer saturation. The protection scheme uses a combination of the percentage differential current principle and the phase comparison principle. A sampling rate of 1440 Hz is used. Existing algorithms for a saturation detector are reviewed and …

    vt Repository record for A microprocessor based bus relay (opens in a new tab)

  2. High-power bi-directional DC/DC converters with controlled device stresses

    … in the isolated high-frequency converters, transformer saturation is an important issue, a method to prevent transformer saturation is proposed and experimentally validated.

    gatech Repository record for High-power bi-directional DC/DC converters with controlled device stresses (opens in a new tab)

  3. A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic for Medium Voltage Dual-Active-Bridge Converters

    The transformer saturation in Dual-Active-Bridge (DAB) converters could be a critical issue. One of the reasons for the transformer saturation is the flux unbalance, including steady-state and transient unbalance. The steady-state flux unbalance is led by converter circuit parameters and modulation …

    ut-knoxville Repository record for A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic for Medium Voltage Dual-Active-Bridge Converters (opens in a new tab)

  4. Modeling and Analysis of Modular Multi-level Converter-Based HVDC Systems to Investigate Geomagnetic Disturbance Effects.

    … share of the MMC in the harmonics resulting from transformer saturation. Also, a mitigating control block is designed and proposed to eliminate major harmonics in the grid current in the case of GMD. It improves the power quality in the grid, and it reduces the risk of blackout in the system. A …

    york Repository record for Modeling and Analysis of Modular Multi-level Converter-Based HVDC Systems to Investigate Geomagnetic Disturbance Effects. (opens in a new tab)

  5. Simulation of power station protection equipment

    … effect is included. Modelling of a current transformer is included because transformer saturation may occur if the fault current is high, and hence the secondary current is distorted. Experiments were carried out to confirm that distorted currents will affect the relay operating time, and it …

    aston Download PDF for Simulation of power station protection equipment (opens in a new tab)

  6. Study of High Impedance Fault Characteristics and Detection Methods

    … such as capacitor switching transients, transformer saturation and load non-linearity.

    unsw Repository record for Study of High Impedance Fault Characteristics and Detection Methods (opens in a new tab)

  7. A New Digital Relay for Dispersed Storage and generation (DSG) Units

    … harmonics that can fail surge arrestors or cause transformer saturation. The new relay will be able to detect this condition at the inter-tie and trip the cogeneration facility. In order to make this multifunction relay cost effective, it includes protection functions for traditional relay …

    vt Repository record for A New Digital Relay for Dispersed Storage and generation (DSG) Units (opens in a new tab)

  8. Modeling and Control of a Single-Phase, 10 kW Fuel Cell Inverter

    … loop, with careful consideration to avoid transformer saturation, is employed for the phase-shifted DC-DC converter. Several experimental transfer functions were measured to confirm the modeling assumptions and verify the control design of the DC-DC converter. Two control options for the …

    vt Repository record for Modeling and Control of a Single-Phase, 10 kW Fuel Cell Inverter (opens in a new tab)

  9. AN ALGORITHM FOR PROTECTING POWER TRANSFORMERS

    … and solid-state relays for protecting power transformers. Differential protection is the conventionally used scheme for the purpose.' With the advent of digital technology, researchers and designers have made remarkable progress in the development of microprocessor-based relays. These relays …

    sask Repository record for AN ALGORITHM FOR PROTECTING POWER TRANSFORMERS (opens in a new tab)

  10. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    During the course of a transformer's operational life, it experiences many challenges to its insulation. Chemical stresses, such as moisture in insulating oil, deteriorate insulation chemically. Mechanical stresses and thermal stresses, such as those experienced during a large external fault, also …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  11. Impact of MHD-E3 on power system equipment and loads.

    … of 1000 amps within the power grid, will cause transformer saturation that leads to abnormal power absorption and high levels of harmonics in the power system. Research herein explores the impact of these direct currents on transformers, the impact of elevated levels of harmonics on power system …

    baylor Repository record for Impact of MHD-E3 on power system equipment and loads. (opens in a new tab)

  12. Ratios-Based Universal Differential Protection Scheme for Power Transformers

    Power transformers are one of the most important and costly components in power systems. It is subject to short circuit faults similar to any other component of the power system. Failure to detect these faults may result in transformer blaze and may subsequently lead to property damage. Therefore, …

    calgary Repository record for Ratios-Based Universal Differential Protection Scheme for Power Transformers (opens in a new tab)

  13. The use of a magnetic model to analyze the load dependent behaviour of a power supply

    … that power supplies based on the ferroresonant transformer technology are incompatible with certain more recent types of loads such as actively power factor corrected devices. This is an issue that still remains today. The objective of this thesis is to analyze whether a specific ferroresonant …

    ubc Repository record for The use of a magnetic model to analyze the load dependent behaviour of a power supply (opens in a new tab) Download PDF for The use of a magnetic model to analyze the load dependent behaviour of a power supply (opens in a new tab)

  14. Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda

    The differential function is widely used in power transformer protection, leading to a reliable discrimination between internal faults and other events associated with power transformer operation. However, the conventional differential protection function based on the estimation of current phasors …

    brazil-ufrn Repository record for Proteção diferencial de transformadores de potência utilizando a transformada Wavelet com efeitos de borda (opens in a new tab)

  15. High-Resolution Time-Synchronized Monitoring and Anomaly Detection in Modern Distribution System

    … half. In Chapter 4, an SVM-based detector for transformer saturation caused by geomagnetically induced currents (GICs) is developed using synchronized harmonic real power derived from the harmonic synchrophasors estimated by the algorithm in Chapter 2. This approach offers a more cost-efficient …

    vt Repository record for High-Resolution Time-Synchronized Monitoring and Anomaly Detection in Modern Distribution System (opens in a new tab)

  16. Design and Control of Power Converters for High Power-Quality Interface with Utility and Aviation Grids

    … ac/dc power transmission,• Analyze the interface transformer saturation issue between ac and dc power flow under line unbalances.• Proposed both passive transformer design and active hybrid-line-impedance-conditioner to suppress this issue.For transmission line emulator,• Propose general …

    utk-theses Repository record for Design and Control of Power Converters for High Power-Quality Interface with Utility and Aviation Grids (opens in a new tab)

  17. Power Electronics Converter Interfaced Power System Emulation Platform Development and Research Demonstration

    … model by combining two complementary ideal transformer model (ITM) interface algorithms are implemented to realize the hybrid emulation stably under different conditions. A time-delay correction method is proposed to compensate the interface time-delay to improve the hybrid emulation …

    utk-theses Repository record for Power Electronics Converter Interfaced Power System Emulation Platform Development and Research Demonstration (opens in a new tab)

  18. Detection, Localization, and Recognition of Faults in Transmission Networks Using Transient Currents

    … signal noise, fault inception angle and current transformer saturation were investigated. The performance of the protection scheme was also tested with the field recorded signals. Hardware prototypes of the fault direction identification scheme and the transient classification system were …

    manitoba Repository record for Detection, Localization, and Recognition of Faults in Transmission Networks Using Transient Currents (opens in a new tab)

  19. Three-phase AC-to-DC soft-switching HF transformer isolated converters with power factor correction and low harmonic distortion

    … single-stage, softswitched, high frequency (HF) transformer isolated converters with power factor correction (PFC) and low harmonic distortion. Four different configurations are presented. Topology of all these four configurations is based on integration of a front-end DCM boost with a soft …

    uvic Repository record for Three-phase AC-to-DC soft-switching HF transformer isolated converters with power factor correction and low harmonic distortion (opens in a new tab)

  20. An improved bus protection technique with dissimilar current transformers

    … relay includes a new technique to detect current transformer saturation. This saturation detector is the Masters thesis work of Dr. Lifeng Yang, an alumnus of Virginia Tech. A newly developed type of measuring device called a Magneto Optic Current Transducer (MOCT) has been installed on both ends …

    vt Repository record for An improved bus protection technique with dissimilar current transformers (opens in a new tab)

Page 1 of 2