High frequency simulation of transformer windings for diagnostic tests
… are not immediately replaceable such as power transformers. High current surges impacting power transformers often cause winding deformations. These pose safety risks and heavy financial losses to the utility in spot market buying when failures occur. Long replacement times can have crippling …
-
Fault Detection of HVDC Transformer Windings using Impedance Protection
Power transformers play a key role in high voltage direct current (HVDC) systems to overcome the limitations of conventional AC transmission and are expensive and fundamental components in power systems. Transformer winding faults are among the most frequent issues in transformers. Since winding …
-
Partial discharge signal propagation, modelling and estimation in high voltage transformer windings
… discharge (PD) propagation within a high voltage transformer winding. Location of PDs and magnitude estimation are important tools for both diagnosis and prognosis of the health of large transformers. In reality there is limited access and knowledge of a winding and consequently any practical …
-
Detection and location of partial discharges in transformer windings using electrical methods
… increase in power ratings of modern high voltage transformers has come a corresponding interest in the value of partial discharge testing for quality control (confirmation that levels of insulation stress in the manufactured unit are acceptable), design of HV equipment and fault diagnosis. A …
-
Classification and localisation of multiple partial discharge sources within high voltage transformer windings
… condition monitoring and diagnostics of power transformers, which can be used as a tool for assessing the lifespan of transformers and can detect insulation malfunctions before they lead to failure. This report describes the development of analytical tools for PD activities within HV …
-
Identification of partial discharge sources and their location within high voltage transformer windings
… with developing a new approach to high voltage transformers condition monitoring, which involve partial discharge (PD) measurement and localisation within high-voltage transformer windings. This is an important source of information for both diagnosis and prognosis of the health of power …
-
MANUFACTURABILITY AND RELIABILITY OF ADDITIVELY MANUFACTURED PLANAR TRANSFORMER WINDINGS USING SILVER-BASED PASTE
… called syringe-printing to create planar transformer windings without the need for pressure, using silver-based paste. The dissertation will address manufacturing considerations such as trace width, gaps, and heights that are printable, as well as the impact of electrical resistivity on …
-
High frequency model for transient analysis of transformer windings using multiconductor transmission line theory
Transients encountered by transformers in power stations during normal operation can have complex oscillatory overvoltages containing a large spectrum of frequency components. These transients can coincide with the natural frequencies of the transformers windings, leading to voltages that can be …
-
A multi-layer neural network approach to identification of mechanical damage in power transformer windings
Power transformers are among the most critical of assets for electric utilities, in the financial impact that their failure can bring. Asset Managers need to be able to determine the right time for replacement, refurbishment or relocation of these devices, with an increasing degree of confidence, …
-
ΜΙΑ ΣΥΜΒΟΛΗ ΣΤΗΝ ΑΝΑΛΥΣΗ ΤΟΥ ΠΕΔΙΟΥ ΣΚΕΔΑΣΕΩΣ ΚΑΙ ΤΗΣ ΠΥΚΝΟΤΗΤΑΣ ΡΕΥΜΑΤΟΣ ΣΕ ΜΕΤΑΣΧΗΜΑΤΙΣΤΕΣ
… AND THE ELECTROMAGNETIC FORCES ACTING ON THE TRANSFORMER WINDINGS. AN ANALYTICAL METHOD FOR THE DETERMINATIONOF THE ELECTROMAGNETIC MAGNITUDES IS THE TRANSFORMER AREA, WHERE THE LAEKAGEFIELD IS EXISTING, HAS BEEN DEVELOPED USING MAXWELL'S DIFFERENTIAL EQUATIONSAND INTRODUCING THE VECTOR …
-
Localization of partial discharge in power transformer winding using electromagnetic time reversal and reciprocity
Power transformers are key elements of power system infrastructure. Their efficiency and reliability influence the overall performance of electric power systems. For this reason, proper maintenance of power transformers is essential for operators to ensure continuous and reliable power delivery to …
-
Power distribution feeder response to the asymmetric saturation of substation transformers caused by significant high-side DC currents.
… can lead to asymmetric saturation of utility transformer cores by causing significant DC current to flow through the transformer windings. Transformer secondary voltage and current waveforms are distorted by core saturation and this distortion can be amplified at points on power distribution …
-
The theory and design of switched-mode power transformers for minimum conductor loss
… power dissipation, and energy storage within transformer windings is presented. Emphasis is placed on applications in switched-mode power conversion. One-dimensional radial variation of the field quantities is assumed. The first phase of the investigation is for sinusoidal excitation; …
-
An Investigation into the Next Generation of Ultra High Voltage DC Power Supplies
… of the selected technologies, the insulated core transformer and the cascade transformer have the greatest capacity for further improvement. Both of these types of power supply contain many common components, as they are both variations on the conventional transformer, adapted to overcome problems …
-
Proteção diferencial de transformadores de potência baseada em máquinas de vetor de suporte e transformada wavelet
Power transformer is one of the main equipment of the electrical system which is responsible for the interconnection of electrical networks at different voltage levels. The protection of this equipment must work quickly and efficiently in cases of internal fault in the transformer, because …
-
Overvoltages and coupling effects on an ac-dc hybrid transmission system
… eliminating dc components of the currents in the transformer windings of a dc converter is presented. The method uses the technique of firing angle modulation. It is shown that merely eliminating the fundamental frequency component on the dc side may not remove this dc component. The impact of …
-
Analysis of high voltage impulse generator circuits
… generator (and with such analogous problems as transformer windings). The gaps cannot in general be assumed to fire simultaneously. The transient voltages are of primary importance in causing their successive breakdown, but the instant of breakdown due to an overvoltage cannot be determined from …
-
Design Considerations on Insulation and Magnetics for Medium Voltage DC/DC Converters
… magnetic cores is proposed for shell-type transformer structures. Then, a 2-D lamination configuration for ribbon- and sheet-based magnetic core is proposed, which further reduces the leakage-induced eddy current loss.</p> <p>Second, a ferrite shielding strategy is introduced to reduce eddy …
-
Multiport Energy Router based Integration of Renewable Energy Sources for Offshore Grid
… and distribution require bulky line frequency transformers and have reactive power losses in the system that increase with the longer step-out distance. In turn, subsea HVDC cables are more efficient, lighter, and cost-effective per unit of transmitted power for long distances than HVAC cables. …