Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"Transient Current Technique"”
-
Transient Current Technique characterization of bonded interfaces for monolithic silicon radiation detectors
This thesis aims at demonstrating a novel technique for the characterization of interfaces obtained by a CMOS-compatible Surface Activated Bonding (SAB) process between silicon wafers. This enables the optimization of the two main components of monolithic silicon detectors, the CMOS circuitry for …
-
Radiation Hard Timing 3D Detectors for Future Colliders
… infraroig en l'equip experimental anomenat "Transient Current Technique" (TCT) i amb una font radioactiva d'estronci-90. A més a més, s'han dut a terme simulacions per sensors 3D especialment dissenyats per aplicacions de temps, comparant la nova geometria hexagonal amb la usual ortogonal.
-
Spectroscopy of defects in wide band-gap semiconductors and heavily irradiated Si /
… during irradiation by 1.6 MeV protons. The transient current technique (TCT) measurements allow a direct evaluation of the most important parameters. In this work, the depth-distribution of native defects in diamond wafers has been identified within the profiles of current transients …
-
Defektų spektroskopija plačiatarpiuose puslaidininkiuose ir stipriai apšvitintame Si /
… during irradiation by 1.6 MeV protons. The transient current technique (TCT) measurements allow a direct evaluation of the most important parameters. In this work, the depth-distribution of native defects in diamond wafers has been identified within the profiles of current transients …
-
The Two Sides of Silicon Detectors
… advantage of reducing radiation-induced leakage current to levels of a few pA, while at 130K the Lazarus Effect plays an important role i.e. minimum voltage required for full depletion. Performing voltage scans on a 'standard' silicon pad detector pre- and post-annealing, the charge collection …
-
Didelių energijų spinduliuočių Si sensorių su vidiniu stiprinimu tyrimas po apšvitų skvarbiaisiais protonais /
… for future experiments are highly desirable. Currently, sensors of pin structure and different types (trip, pixel) are widely employed. However, sensors of pin structure suffer from a decrease in charge collection efficiency. Sensors with internal gain layer (Low Gain Avalanche Detectors - …
-
Physical effects of 3-phenylindole on ion transport across bilayer lipid membranes
… anions, as determined by the voltage-step transient current technique, decreased slightly when 3PI was present in the aqueous phase. From the voltage dependence of the normalized steady state conductivity it was shown that 3PI did not kinetically limit tetraphenylarsonium transport but that …
-
Development of a two-photon absorption - TCT system and study of radiation damage in silicon detectors
… of annealing time by measurements of the leakage current and the capacitance and by<br>measurements using the Transient Current Technique (TCT). An initial decrease of gain, as well as a reduction of the gain layer depletion voltage was observed after irradiation. No further change of gain with …
-
Characterisation of advanced silicon pixel detector prototypes for the Inner Tracker of the ATLAS experiment for the High Luminosity LHC
… and their effects on charge sharing, a new edge-transient current technique facility was built. Results from these measurements identified charge-sharing fractions for a range of pixel and electrode dimensions. In an effort to qualify all mechanical structure (stave) prototypes being considered for …
-
INVESTIGATION OF SINGLE CRYSTAL DIAMOND FOR SWIFT HEAVY ION BEAM DETECTORS AND STUDY OF DIAMOND GROWTH FOR IMPROVEMENT OF DIAMOND MATERIAL FOR DETECTORS
… irradiation, samples ware characterized by the transient current technique (TCT) to understand how charge transport properties get affected by the beam irradiation. The charge collection efficiency (CCE) and the lifetime of the holes and electrons created were studied. A completely …
-
Silicon pixel detectors for synchrotron applications
… a short, double sided 3D strip detector was a Transient Current Technique (TCT) experiment. The TCT technique allows the electric field in the 3D devices to be probed in a way not possible before. The TCT technique uses the current waveform produced by the detector in response to a near delta …
-
Componenti optoelettronici per applicazioni di ricerca aerospaziale e nucleare
… laser ad infrarossi pulsata basata sulla tecnica Transient Current Technique (TCT). Vengono inoltre riportati i risultati della modellazione TCAD, utilizzati per verificare la dipendenza del guadagno del rivelatore dalla tensione di polarizzazione applicata e dall'intensità del laser in ingresso. …