Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 82 for “"Transient measurements"”
-
Effectiveness of energy wheels from transient measurements
… This research uses a new, low-cost, transient method to predict the effectiveness using only data obtained from transient measurements.In this thesis, an analytical model is presented for predicting the effectiveness of rotating energy wheels using only the characteristics measured on …
-
Determination of the induction machine parameters from starting transient measurements
… voltages and mechanical speed from a starting transient. The dynamic equations of the induction machine are expressed in the synchronous reference frame because in this reference the values of the direct and quadrature currents have a slower variation than those in the other reference frames. …
-
Parameter estimation for single-phase induction motor from transient measurements
… the responses of SPIMs in both steadystate and transient conditions. Firstly, they are calculated from multiple sets of steady-state test-based measurements using the Newton-Raphson (NR) method. The NR-based algorithm iteratively solves a system of non-linear equations involving the parameter …
-
A Time Domain Deconvulution Technique For The Correction Of Transient Measurements.
Techniques for correcting transient measurements can be considered as "deconvolving" or solving the convolution integral equation R(t)=F(0) * C(t) + ∫t_0 C(t- Τ) [dF(T)/dT] dT for the input, F(t), given the response, R(t), and response of the measurement system to a step input of unit magnitude, …
-
Applications of Chlorophyll Fluorescence Transient Measurements to the Functional Analysis of Photosynthetic Processes
Made available in DSpace on 2015-05-14T15:10:01Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 7915384.PDF: 3245502 bytes, checksum: ad1c321b2bf4fc85a7d3d49ee6f26240 (MD5) Previous issue date: 1979
-
Steady state and transient measurements within a compressor rotor during steam-induced stall at transonic operational speeds
… of Fast Fourier Transform waterfall plots of the transient data before and during stall proved invaluable in determining stall precursors as well as the mode of rotor stall. In addition, a new computational fluid dynamic model was designed using CFX-5 software to represent a single blade passage …
-
Inlet flow-field measurements of a transonic compressor rotor prior to and during steam-induced rotating stall
… stall and included steady-state as well as transient measurements in the inlet of a transonic compressor prior to and during a steaminduced stall. Hotwire measurements of the inlet flow field were taken to determine an inlet turbulence intensity of 2-3% during both subsonic as well as …
-
Simulation and interpretation of formation-tester measurements acquired in the presence of mud-filtrate invasion and geomechanical deformation
… formation mobility. However, formation-tester measurements are invariably influenced by mud-filtrate invasion due to drilling overbalance pressure, thereby affecting the acquisition of uncontaminated fluid samples and the estimation of in-situ petrophysical properties. Moreover, in cases of …
-
Distributed parameter RC network analysis
… R and C of a uniform RC microcircuit from transient measurements are included"--Abstract, page ii.
-
The electrochemical reduction of fumaric acid on Hg-Bi cathodes
… for both undissociated fumaric acid and H⁺. Transient measurements indicated low coverages of adsorbed fumaric acid and no adsorbed hydrogen species in the potential region of the reaction. A reaction mechanism is proposed which involves a chemical rate determining step between an adsorbed …
-
Development of an electronic sensor for engine exhaust particulate measurements
… flame in a flow tunnel. Steady-state engine measurements were made over a range of speed and load conditions while transient measurements were performed during engine start-ups and accelerations. The sensor response was compared to an opacity meter, gravimetric filter measurements, an …
-
Effects of power pulsations on natural convection from discrete heat sources
… been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. …
-
Effects of power pulsations on natural convection from discrete heat sources.
… been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. …
-
Identification and visualization of electromagnetic coupling paths & nonlinear capacitors for ESD protection
… are measured using static and nanosecond transient measurements. The ESD protection effectiveness with different material capacitors are compared by simulation"--Abstract page iv.</p>
-
Unsteady casewall pressure measurements in a transonic compressor during steam induced stall
… In the present study, steady-state as well as transient measurements prior to and during a steam induced rotating stall were taken. Changes to the honeycomb altered the performance characteristics of the Transonic Compressor Rig and needed to be remapped in order to determine a new stall line …
-
Transient Safe Operating Area (tsoa) For Esd Applications
… Discharge (ESD) time frame is developed through measurements and Technology Computer Aided Design (TCAD). A set of parameters based on transient measurements are used to define Transient Safe Operating Area (TSOA). The parameters are then used to assess effectiveness of protection devices for …
-
Dynamic response of polycrystalline organic thin film transistors
… to directly measured velocities measured from transient measurements. New device structures are fabricated in order to provide low voltage operation, along with a method to stabilize the output response and reduce bias stress effects. A novel method is proposed to investigate the dynamics of …
-
Device physics of organic field effect transistors and organic photovoltaic devices
… (OFETs), respectively, and novel pulsed voltage transient measurements were developed in order to extract transient mobilities and carrier velocities from the transistor response of the device, which were well correlated with the corresponding DC OFET characteristics. A distributed RC network was …
Page 1 of 5