Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 4 of 4 for “"Transmission densitometry"”.
-
Using the contrast ratio method and achromatic transmission densitometry as a substitute for Status A transmission densitometry with the Photographic Activity Test For Enclosure Materials
… of conventional photographic spot-reading transmission densitometers -including the widely adopted X-Rite model 310- due to the rapid decrease in demand for analogic photographic laboratory work has had a broadly felt effect in the conservation community. In the cultural heritage …
-
Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components
… this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray …
-
Defect and thickness inspection system for cast thin films using machine vision and full-field transmission densitometry
… functionality, so a real-time, full-field transmission densitometer has been created to measure the bi-directional thickness profile of the semi-transparent PEM between 25-400 micrometers. The local thickness of the 75 mm x 100 mm imaged area is determined by converting the optical density …
-
Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields
… with film structure for optimal film readout (densitometry) sensitivity; range of absorbed dose measurements; dependence of film dose measurement response as a function of changing radiation energy; fractionation and dose rate effects on film measurement response; film response sensitivity to …