  1. Using the contrast ratio method and achromatic transmission densitometry as a substitute for Status A transmission densitometry with the Photographic Activity Test For Enclosure Materials

    … of conventional photographic spot-reading transmission densitometers -including the widely adopted X-Rite model 310- due to the rapid decrease in demand for analogic photographic laboratory work has had a broadly felt effect in the conservation community. In the cultural heritage …

    rit Repository record for Using the contrast ratio method and achromatic transmission densitometry as a substitute for Status A transmission densitometry with the Photographic Activity Test For Enclosure Materials (opens in a new tab)

  2. Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components

    … this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray …

    gatech Repository record for Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components (opens in a new tab)

  3. Defect and thickness inspection system for cast thin films using machine vision and full-field transmission densitometry

    … functionality, so a real-time, full-field transmission densitometer has been created to measure the bi-directional thickness profile of the semi-transparent PEM between 25-400 micrometers. The local thickness of the 75 mm x 100 mm imaged area is determined by converting the optical density …

    gatech Repository record for Defect and thickness inspection system for cast thin films using machine vision and full-field transmission densitometry (opens in a new tab)

  4. Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields

    … with film structure for optimal film readout (densitometry) sensitivity; range of absorbed dose measurements; dependence of film dose measurement response as a function of changing radiation energy; fractionation and dose rate effects on film measurement response; film response sensitivity to …

    duke Repository record for Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields (opens in a new tab)