Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 55 for “"Transmural pressure"”.

  1. The shape of an elastic boundary deformed by transmural pressure

    … involving flexible boundaries subjected to transmural pressure differences. During the thesis, we explore a few example problems with the common theme of finding the shape profile of these flexible boundaries. We begin with the problem of a cross section of an elastic tube that is subjected to a …

    east-anglia Download PDF for The shape of an elastic boundary deformed by transmural pressure (opens in a new tab)

  2. The effect of initial arteriolar transmural pressure on vasodilation at the onset of muscle contraction

    … blood flow are unclear. Below the heart, blood pressure is larger in the arterial system due to gravity (called transmural pressure). Arterioles vasodilate in response to a reduction in transmural pressure, termed myogenic vasodilation. During muscle contraction, transmural pressure is reduced. …

    queens Repository record for The effect of initial arteriolar transmural pressure on vasodilation at the onset of muscle contraction (opens in a new tab)

  3. Effect of changes in left atrial transmural pressure on plasma ADH levels in the goat

    This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).

    iupui Repository record for Effect of changes in left atrial transmural pressure on plasma ADH levels in the goat (opens in a new tab)

  4. Understanding Exercise-Induced Pulmonary Hemorrhage in Horses: Investigating the Vascular and Ventilatory Dynamics of Transmural Pressure

    … stress failure, which occurs when the capillary transmural pressure (Ptm; the difference in pressure across the thin membrane separating the alveoli from the capillaries) exceeds a given threshold. Although Ptm cannot be measured, it can be calculated using pulmonary capillary (vascular) and …

    calgary Repository record for Understanding Exercise-Induced Pulmonary Hemorrhage in Horses: Investigating the Vascular and Ventilatory Dynamics of Transmural Pressure (opens in a new tab)

  5. An Experimental Study of Fluid-Structure Interaction in Collapsible Vessels

    … a thin-walled collapsible vessel. The effects of transmural pressure and flow rate were characterized experimentally using high-frequency pressure transducers and optical measurements. Various transmural pressures were also simulated through finite element analysis. Results suggest that the …

    ndsu Repository record for An Experimental Study of Fluid-Structure Interaction in Collapsible Vessels (opens in a new tab)

  6. INVESTIGATION ON FLUID FLOW IN FLEXIBLE AND COLLAPSIBLE TUBES

    … flow in a compliant tube subjected to varying pressure drop and transmural pressure differences. The experimental results were presented in non-dimensional parameters, Q/(AoCo) and (P - Pe)/Kp, and compared with theory. Two main types of cases were considered, one with upstream stagnation …

    nus Repository record for INVESTIGATION ON FLUID FLOW IN FLEXIBLE AND COLLAPSIBLE TUBES (opens in a new tab) Download file for INVESTIGATION ON FLUID FLOW IN FLEXIBLE AND COLLAPSIBLE TUBES (opens in a new tab)

  7. Contribution of Arteriolar Distension to Rapid Onset Vasodilation Following a Single Contraction

    … smooth muscle exerts an inward force, with blood pressure exerting an outward acting force, so when the vascular smooth muscle relaxes, it exerts less force, resulting in vasodilation. The elastic structure of arterioles also exerts an inward acting elastic recoil force. However, due to its …

    queens Repository record for Contribution of Arteriolar Distension to Rapid Onset Vasodilation Following a Single Contraction (opens in a new tab)

  8. Effects of Transmural Distending Pressure on Integrated Venous Function in Normal Rat.

    … also investigated under conditions of changing transmural distending pressure. We also evaluated the relative contribution of alpha adrenergic (α-A) and endothelinergic receptors to NE and ET-1 contractile responses, respectively. Additionally, the effects of changing transmural pressure on …

    guelph Repository record for Effects of Transmural Distending Pressure on Integrated Venous Function in Normal Rat. (opens in a new tab)

  9. Structural and functional characterization of a lymphatic system using computational and experimental approaches

    … The valves aid in transporting lymph against a pressure gradient, in addition to the lymphangion pump which exhibit cyclical variations in diameter. Like blood vessels, baseline lymphatic tone is regulated with changes in transmural pressure; however, the transient response of lymphatic …

    tamu Repository record for Structural and functional characterization of a lymphatic system using computational and experimental approaches (opens in a new tab)

  10. Characterization of lymphatic pump function in response to mechanical loading

    … shear stress and circumferential stress due to transmural pressure affect pumping response; however, anything other than simple, static relationships remain unknown. Because mechanical environment has been implicated in lymphatic diseases such as lymphedema, understanding these dynamic …

    gatech Repository record for Characterization of lymphatic pump function in response to mechanical loading (opens in a new tab)

  11. Effects of Altitude on Pressure-Flow Relationships in the Vascular Bed of the Hind Limb of the Dog

    … to study the effects of decreasing barometric pressure upon the pressure-flow relationships in a peripheral vascular bed in an attempt at better delineation of the autoregulatory mechanisms. A decrease in barometric pressure does influence the transmural pressure and could theoretically affect …

    unt Repository record for Effects of Altitude on Pressure-Flow Relationships in the Vascular Bed of the Hind Limb of the Dog (opens in a new tab)

  12. On the Prediction of Pulsatile Flows in Constricted Elastic Vessels

    … diameter due to the increment of circumferential pressure is modelled via a novel moving boundary approach. Model predictions compare well against measured and numerical data for the centreline and axial velocities, thickness of the flow separation zones and radial wall displacements. The …

    unsw Repository record for On the Prediction of Pulsatile Flows in Constricted Elastic Vessels (opens in a new tab)

  13. Modelling Wall Deformation and Fluid-Structure Interaction in Fluid-Conveying Elastic-Walled Tubes

    … which are induced by an azimuthally uniform transmural pressure. In Chapter 2, we expand on this model to allow arbitrary initial cross-sectional shapes and azimuthally non-uniform pressures. In Chapter 3, we re-visit the problem for the deformations of an initially elliptical tube and …

    east-anglia Download PDF for Modelling Wall Deformation and Fluid-Structure Interaction in Fluid-Conveying Elastic-Walled Tubes (opens in a new tab)

  14. Computational framework for modeling blood clotting in extravascular injuries, A

    … new framework, we investigate the influence of transmural pressure and injury size on clot structure and occlusion times in extravascular injuries. We found that increasing the transmural pressure prolonged the occlusion times and increased the density of the blood clots that formed in the …

    colo-mines Repository record for Computational framework for modeling blood clotting in extravascular injuries, A (opens in a new tab)

  15. Lymphatic Functional Adaptations to Prolonged Changes in Mechanical Stimuli

    … contend with the wide ranges of lymph flow and pressure. Sharing with blood vessels an acute sensitivity to mechanical stresses, lymphangions could be expected to be similarly sensitive to prolonged changes in transmural pressure and flow. The purpose of this research was to quantify the …

    tamu Repository record for Lymphatic Functional Adaptations to Prolonged Changes in Mechanical Stimuli (opens in a new tab)

  16. The role of TRPV4 in flow-mediated inhibition of rat mesenteric collecting lymphatic vessel pumping

    Lymphatic contractility is modulated by transmural pressure and shear stress exerted by the lymph on the lymphatic vessel wall. It has previously been shown that in rat mesenteric collecting lymphatic vessels, lymph flow inhibits lymphatic contractility in an endothelial nitric oxide synthase …

    calgary Repository record for The role of TRPV4 in flow-mediated inhibition of rat mesenteric collecting lymphatic vessel pumping (opens in a new tab)

  17. Normalization of microvascular physiology in engineered microvessels via cyclic adenosine monophosphate supplementation and artificial lymphatic drainage

    … in causing a rapid increase in interstitial pressure, which can decrease transmural pressure and may explain the correlation between vascular collapse and barrier dysfunction. Inspired by the physiological role of lymphatic vessels in interstitial fluid drainage, I hypothesized that a system …

    bu Repository record for Normalization of microvascular physiology in engineered microvessels via cyclic adenosine monophosphate supplementation and artificial lymphatic drainage (opens in a new tab)

  18. Contribution of potassium channels to myogenic response in skeletal muscle arterioles: effects of age and fiber type

    … isolated skeletal muscle arterioles, increasing transmural pressure causes an increase in constriction. This active myogenic response varies with age and fiber type. Increased transmural pressure activates both Ca2+-activated (KCa) potassium channels and voltage-dependent (Kv) potassium channels; …

    tamu Repository record for Contribution of potassium channels to myogenic response in skeletal muscle arterioles: effects of age and fiber type (opens in a new tab)

  19. Collapsible Silicone Tubes: An in Vitro Model for Tracheal Traction

    … experimental setup was developed that included a pressure catheter to measure air pressure in the tube lumen, a pump that generated sinusoidal bidirectional flow, and a laser line scanner to monitor deformations of the tube wall. The buckling pressure (pressure at which the tube collapses) was …

    marquette Repository record for Collapsible Silicone Tubes: An in Vitro Model for Tracheal Traction (opens in a new tab)

Page 1 of 3