Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 52 for “"Treatment Planning System TPS"”.

  1. Dose Analysis by Radiation Treatment Planning System (TPS) Software Vs. Thermoluminescent Dosimeters Output

    … optimize dose to specific regions defined by the treatment plans, which may involve irradiations from multiple angles. It is important that doses to healthy tissue not exceed tolerance doses and that the dose to the tumor be maximized. To accomplish these objectives, commercially available …

    ut-knoxville Repository record for Dose Analysis by Radiation Treatment Planning System (TPS) Software Vs. Thermoluminescent Dosimeters Output (opens in a new tab)

  2. A Comparison of Small Field Output Factors for Stereotactic Radiation Therapy

    … 15.6 (AXB) algorithm in Varian’s Eclipse treatment planning system (TPS). The primary goal is to validate the extended AXB (AXBe) model’s accuracy in calculating dose for small-field geometries, which are known to be challenging for conventional dosimetry. Measurements were conducted using …

    gatech Repository record for A Comparison of Small Field Output Factors for Stereotactic Radiation Therapy (opens in a new tab)

  3. Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles

    … to a patient undergoing electron radiation treatment is dependent upon the configured electron dose calculation algorithm in the treatment planning system (TPS). Configuration of the electron Monte Carlo (eMC) algorithm in the Eclipse TPS requires a variety of beam scan data. One of the …

    unlv Repository record for Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles (opens in a new tab) Download PDF for Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles (opens in a new tab)

  4. Alterações agudas da tireoide após radioterapia não dirigida à glândula em crianças e adolescentes, e dosimetria in vivo para a tireoide de diferentes regiões corporais irradiadas

    … 131I uptake were also performed before and after treatment. The scattered dose to the thyroid region was estimated with a treatment planning system (TPS) or measured with thermoluminescent dosimeters (TLDs). Results: The median radiation dose scattered to the thyroid was 296.6 cGy (IQR …

    brazil-ufrgs Repository record for Alterações agudas da tireoide após radioterapia não dirigida à glândula em crianças e adolescentes, e dosimetria in vivo para a tireoide de diferentes regiões corporais irradiadas (opens in a new tab)

  5. Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems

    … Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated proton minibeam system using TOPAS simulations and experimental measurements. It then used the open-source treatment planning system (TPS), MCSquare, to compare the results of Class-II Monte …

    gatech Repository record for Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems (opens in a new tab)

  6. A Portal imager-based patient dosimetry system

    … transmission through the patient at the time of treatment. For an IMRT field, the portal image signal is back-projected through a model of the patient in order to calculate the dose at the isocentric plane perpendicular to the beam central axis. The IMRT in vivo dose verification technique was …

    uvic Repository record for A Portal imager-based patient dosimetry system (opens in a new tab)

  7. Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy

    … can use ArcCHECK diode measurements along with treatment planning system (TPS) data to guide a full 3D dose reconstruction. The ArcCHECK phantom, along with 3DVH software was evaluated as a volumetric modulated arc therapy (VMAT) pretreatment verification tool. The comprehensive evaluation of …

    uvic Repository record for Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy (opens in a new tab)

  8. Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy

    … accelerator jaws. Methods: Clinical radiation treatment plans for 10 thoracic, 3 pediatric and 3 head and neck patients were converted to plans with the jaws tracking each segment’s MLC apertures. Each segment was then renormalized to account for the change in collimator scatter to obtain …

    uthsc Repository record for Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy (opens in a new tab)

  9. Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom

    … Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy …

    uthsc Repository record for Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom (opens in a new tab)

  10. Identifying Treatment Planning System Errors In Iroc-Houston Head and Neck Phantom Irradiations

    Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators …

    uthsc Repository record for Identifying Treatment Planning System Errors In Iroc-Houston Head and Neck Phantom Irradiations (opens in a new tab)

  11. Electronic Compensation to Deliver a Total Body Radiation Dose

    … technique used to suppress a patient’s immune system and eradicate residual cancerous or malignant cells that are resistant to - or cannot be reach by - chemotherapy. Conventional TBI uses large parallel-opposed fields with manual placement of lead compensators to adjust for the varying …

    buffalo Repository record for Electronic Compensation to Deliver a Total Body Radiation Dose (opens in a new tab)

  12. A Method for Online Dose Prediction for Image Guided Proton Therapy

    … CBCT (RefCBCT) matching the anatomy of a treatment planning CT (TPCT) and a secondary CBCT (SecCBCT) taken as part of an IGRT setup sequence could be used to consistently and accurately predict the daily dose distribution using the original treatment plan as a guide. In the interest of …

    gatech Repository record for A Method for Online Dose Prediction for Image Guided Proton Therapy (opens in a new tab)

  13. A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices

    <p>Intensity-Modulated Radiation Treatment (IMRT) requires patient-specific quality assurance measurements, which can benefit from the convenience of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due …

    mcmaster Repository record for A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices (opens in a new tab)

  14. Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    … and boundary profiles generated from the treatment planning system (TPS). The method was extended to include conformal and enhanced dynamic wedge (EDW) fields. A method was devised for the automatic calculation of areas (to establish the appropriate scatter correction) from the EPID image …

    glasgow Download PDF for Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device (opens in a new tab)

  15. Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy

    … radiation therapy (SABR) for liver cancer treatments and investigate the gating parameters for acceptable plan delivery in terms of the dose to a moving volume and treatment delivery time. 10 patient plans for VMAT SABR liver were created using the Eclipse™ treatment planning system (TPS). …

    ubc Repository record for Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy (opens in a new tab) Download PDF for Developing quality assurance procedures for gated volumetric modulated arc therapy in stereotactic ablative radiation therapy (opens in a new tab)

  16. Development of a Computational Treatment Planning System for Radiofrequency Ablation of Vertebral Metastases

    … palliatively treat vertebral metastases. Current treatment practices incorporate little to no treatment planning and utilize two-dimensional imaging to localize the vertebra of interest. This may lead to inadequate treatment dose or delivering dose to healthy tissues. To address the need for …

    queens Repository record for Development of a Computational Treatment Planning System for Radiofrequency Ablation of Vertebral Metastases (opens in a new tab)

  17. Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation

    … of dose calculations for various aspects of a treatment planning system (TPS) using an energy fluence beam modelling has been evaluated. The investigated TPS uses a beam model, which separates the energy fluence into a number of sources in the treatment head. The energy fluence components are …

    lund Repository record for Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation (opens in a new tab) Download PDF for Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation (opens in a new tab)

  18. Dose Calculation and Prediction Methods for Gamma Knife Stereotactic Radiosurgery

    … works contribute towards the larger goal of treatment plan prediction and are seen as intermediate steps towards that end. The approximation of dose distributions was motivated by the closed nature of the GK system, which causes complications with the evaluation of the predictions made by the …

    lsu-thes Repository record for Dose Calculation and Prediction Methods for Gamma Knife Stereotactic Radiosurgery (opens in a new tab)

  19. Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging

    … of dose deposited in the patient during treatment. IVD can be of great use in early detection of harmful errors, for assessment of patient setup and anatomy changes, and to guide adaptive radiotherapy. Routine IVD is hindered by the costs and complexities associated with most systems, and …

    calgary Repository record for Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging (opens in a new tab)

  20. Four dimensional dose calculations and planning strategies for dynamic tumour tracking treatments

    … (4D) dose calculation methods and 4D treatment planning strategies for creating and assessing real-time dynamic tumour tracking (DTT) treatment plans on the Vero4DRT (Vero) linear accelerator. Currently DTT treatments are created, optimized, and evaluated on a single breathing phase …

    ubc Repository record for Four dimensional dose calculations and planning strategies for dynamic tumour tracking treatments (opens in a new tab) Download PDF for Four dimensional dose calculations and planning strategies for dynamic tumour tracking treatments (opens in a new tab)

Page 1 of 3