Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 56 for “"Triaxial cell"”
-
Ko consolidation with simultaneous hydraulic conductivity measurement in a modified triaxial cell using flow-pump methods
Includes bibliographical references.
-
Ensaios triaxiais de carga repetida de uma brita
… a crushed-stone aggregate, were made in a large triaxial cell on specimens 100 mm in diameter. Stresses were applied using a pneumatic loading sistem and axial strains were measured using two LVDT's mounted on the top cap. Permanent axial deformation was also observed with a dial gage attached to …
-
Effects of anisotropy on the behaviour of unsaturated compacted clay
… subsequently compressed isotropically in a large triaxial cell. The pressure required to compress the samples isotropically in the large triaxial cell was selected in such a way that it would give a specific volume of either 2.2 or 1.98, which is equivalent to the specific volume of the samples …
-
Triaxial Behaviour of Layered Soil at Small Strain Level
… to conduct K0-compression tests in a rigid triaxial cell with a flexible lateral boundary for the determination of the K0-value of normally consolidated soil. The error induced by the compliance of the cell-water system that always existed in the previous study was successively eliminated by …
-
Investigation into the applicability of AVO techniques to coal mine exploration
… (UK). It moreover presents a modification of a triaxial cell aimed at calibrating AVO in the laboratory, and thereby improving the quality of AVO analysis in general. The analysis presented in this PhD thesis leads to the conclusion that in this region, the particular rock properties can lead to …
-
Triaxial behaviour of partially saturated granular soils at low stress levels.
… (about 5m below the ground) A new double-wall triaxial cell has been designed for testing partially saturated granular specimens with height/diameter equalt o 375 mm/150m m, at low stress levels. The cell is able to make separate measurements and control of the pore air and pore water …
-
Assessment of the triaxial falling head permeability testing technique
… each parameter on the results obtained from the triaxial falling head permeability test. The conclusions reached in this report indicate that to obtain the coefficient of permeability for the saturated condition, the falling head tests should be performed in a triaxial cell"--Abstract, page ii.
-
Stiffness of unsaturated compacted clays at small strains
… the dry unit weight and degree of saturation. A triaxial cell equipped with piezoelectric transducers was developed to investigate the effects of compaction water content, dry unit weight, and degree of saturation on soil stiffness under undrained test conditions. Shear and compression wave …
-
Considerações sobre ensaios triaxiais em areias
… art on testing techniques employed in drained triaxial tests on sands. A study of a new method of specimen preparation using pluviation, where the unit weight of the sample can be previously specified, is also presented. ln addition, a simplified saturation technique in which the specimens were …
-
Creep of saturated soil at different temperatures
… work consisted of the following two types of triaxial tests: 1. Unconsolidated undrained tests on cylindrical specimens without pore pressure measurements. 2. Consolidated undrained tests on cylindrical specimens with pore pressure measurements. A triaxial machine equipped with a non-flow null …
-
The simulation of sampling disturbance and its effects on the deformation behaviour of clays.
… was simulated by applying a strain cycle in the triaxial cell. Comparative tests on 'disturbed' and 'undisturbed' specimens were conducted in a specially designed 100 mm hydraulic triaxial apparatus. Tests were also carried out in a 38 mm triaxial cell to study the effects of loading rate and …
-
PERFORMANCE OF GRANULAR COLUMNS IN SOFT CLAY
… soil reinforced by granular columns. A modified triaxial cell was used in the project so that trivial compression tests could be perform on the 100 mm composite specimens. Four different area ratios (the ratio of the area of the column to the area of the unit cell) were investigated, a=0.14, …
-
The triaxial vane apparatus with stress control.
… uses a miniature vane incorporated into a triaxial cell in order to study the use of the vane in different soils as well as allowing the effects of different vane parameters, such as rotation rate and vane geometry, to be studied in controlled conditions. Initial research was conducted into …
-
Impact of undrained deformation on the hydraulic conductivity of cement-bentonite barrier material
… response and hydraulic conductivity of CB in the triaxial cell. This was investigated using a CB mixture comprising of 80% GGBS as a cement-replacement material under triaxial unconsolidated-undrained loading expected to occur during short-term curing ages (i.e. for specimens cured up to 90 days). …
-
Mathematical Modeling and Dynamic Analysis of the Fast Triaxial Shear Device
… model and dynamic behavior of the Fast Triaxial Device (FTSD). The FTSD is a triaxial cell which loads its 0.75 inch diameter by 1.5 inch long cylindrical specimen by displacing the top of the specimen downward at a rapid rate. To date, specimens ahve been brought to failure in as little …
-
Drainage and settlement characteristics of hydraulic fills
… using conventional oedometer and modified triaxial cell to measure the settlement of hydraulic fills. It has been found that the immediate settlement and time dependent settlement contributes equally to the total settlement. Pore water pressure dissipation has observed using modified …
-
Experimental study of tunnels in squeezing ground conditions
… The physical model included a large true-triaxial cell, a miniature tunnel boring machine (TBM), a laboratory-prepared synthetic test specimen having properties similar to natural mudstone, and instrumentations to monitor deformations around the tunnel boundary during and after the …
-
Hydro-Mechanical Behaviour of Tailings in Unsaturated Conditions
… was carried out by using a suction controlled triaxial cell and imposing different hydro-mechanical stress paths. Statically compacted silty samples were subjected at different suction levels, then isotropically consolidated at different net stresses, and finally sheared at constant water …
Page 1 of 3