Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"True coincidence"”.
-
An algorithm for the simultaneous reconstruction of the radionuclide activity distribution and attenuation map based on PET scatter data
… approach is needed. Previous studies using true coincidence data to simultaneously reconstruct the attenuation map and radionuclide activity distribution suffer from the cross-talk between the distributions. In this study, the scatter data of PET was used to reconstruct the electron density …
-
Photodisintegrationof 3H and Supporting Experiments
… Neutrons were detected both individually and in coincidence to map differential cross section as a function of angle. Measurements were made using circularly polarized γ-rays at 23.7 and 32.0 Mev. These measurements are the first anuglar differential cross section measurements performed for the …
-
Multispectral gamma-ray analysis using clover detectors with application to uranium fission product analysis
… counting geometry involved with this system, true-coincidence summing factors must be calculated, and are done so in part by measuring the peak-to-total ratios of the system in its various counting modes across a wide energy range. The dead-time for the system can be complicated due to the …
-
Model-based randoms correction for 3D positron emission tomography
Random coincidences (randoms) are frequently a major source of image degradation and quantitative inaccuracies in positron emission tomography. Randoms occurring in the true coincidence window are commonly corrected for by subtracting the randoms measured in a delayed coincidence window. This …
-
Ανάπτυξη τεχνολογίας για ραδιολογικό χαρακτηρισμό καταλοίπων με εμπλουτισμό σε φυσικά ραδιονουκλίδια (NORM waste) που προέρχονται από βιομηχανίες πετρελαίου
… density effects on FEPE efficiency curves and true coincidence summing checking for the measurement configurations that were used. Subsequently, gamma spectrometry measurements were performed in the field, where, except for the experimental validation of the MCNP-X models that were developed, …
-
Ανάπτυξη και εφαρμογή τεχνικών προσδιορισμού πολύ χαμηλών συγκεντρώσεων ραδιενεργών ιχνοστοιχείων σε δείγματα περιβαλλοντικής σημασίας
… - N.T.U.A in order to take into account both the true coincidence phenomenon during spectrum collection and to simulate a Compton Suppression system consisting of two independent detectors (primary detector and secondary detector or active shield) that communicate with each other.One of the main …
-
Ανάπτυξη και εφαρμογή τεχνικών εκτίμησης της ακτινικής επιβάρυνσης του πληθυσμού από καταστάσεις πυρηνικής ή ραδιολογικής έκτακτης ανάγκης
… as well as a correction methodology for the true coincidence phenomenon was developed using the Monte Carlo code "PENELOPE". The quality system and proper implementation of the above were validated through participation in interlaboratory exercises, which are described in detail in this …
-
Parameterizing Image Quality of TOF versus Non-TOF PET as a Function of Body Size
… and acquisition duration, the number of measured true coincidence events will decrease, and the background fractions will increase. Another size-related factor, independent of attenuation, is the volume throughout which the measured coincidence counts are distributed: for a fixed acquisition …
-
Ανάπτυξη και εφαρμογή μετρητικών τεχνικών για την ανάλυση της φυσικής και της τεχνολογικά επαγόμενης ραδιενέργειας σε οικοσυστήματα
… were also used for the calculation of the true coincidence correction factors. The proposed technique was based on the use of the program TrueCoinc that was developed by the Institute of Experimental Physics, Kossuth University, Hungary. The technique requires the determination of a full …
-
Αξιολόγηση και βελτιστοποίηση ιατρικών απεικονιστικών συστημάτων ποζιτρονιακής τομογραφίας με χρήση αλγόριθμων προσομοίωσης Monte Carlo
… of energy windows, dead time responses, coincidence time windows and sizes of human patient body. The criterion employed for the determination of either the optimal dose for a given scan time, or the optimal scan time for a given dose, has always been the maximization of the Noise …
-
Study of the ionizing radiation field around accelerators
… the material and the factor that estimates the true coincidence summing (TCS) effect that is caused due to the emission of multiple gamma and X-rays in cascade with negligible time delay. To apply the self-absorption factor corrections and adjust the final photopeak efficiency, a realistic …