Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Tube Columns"”.

  1. Behaviour of elliptical tube columns filled with self-compacting concrete

    … to investigate the behaviour of elliptical tube columns filled with self-compacting concrete (SCC). In total, ten specimens, including two empty columns, were tested to failure. The main parameters investigated were the length and the sections of the columns, and the concrete compressive …

    bradford Repository record for Behaviour of elliptical tube columns filled with self-compacting concrete (opens in a new tab)

  2. Connections between steel beams and concrete -filled steel tube columns

    Concrete filled tube (CFT) columns combine steel and concrete in one member, which results in a member that has the beneficial qualities of both materials. Although CFT columns are suitable for tall buildings in high seismic regions, their use has been limited due to lack of information about the …

    nebraska Repository record for Connections between steel beams and concrete -filled steel tube columns (opens in a new tab)

  3. Axial load capacity of circular steel tube columns filled with high strength concrete

    … load capacity of circular Concrete Filled Steel Tube columns using High Strength Concrete (CFST-HSC). Emphasis is drawn to the enhanced axial capacity of short columns attributed to the lateral confinement of the concrete infill provided by the steel encasement. The degree of confinement has been …

    vu-aus Download PDF for Axial load capacity of circular steel tube columns filled with high strength concrete (opens in a new tab)

  4. Analytical and experimental study on slender concrete-filled steel tube columns and beam-columns

    The use of composite steel-concrete columns and beam-columns in many structural systems is increasing globally due to the intrinsic synergy when these materials are designed and detailed together properly. However, limited test data are available to justify the structural system response factors …

    gatech Repository record for Analytical and experimental study on slender concrete-filled steel tube columns and beam-columns (opens in a new tab)

  5. Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams

    … (MRFs) consisting of concrete filled steel tube (CFT) columns and steel I beams through targeted studies utilizing advanced computational methodologies calibrated on the basis of existing experimental results and to propose a preliminary performance-based seismic design method for this kind …

    greece Repository record for Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams (opens in a new tab)

  6. ESTUDIO NUMÉRICO DE LA CAPACIDAD PORTANTE DE COLUMNAS MIXTAS CON DOBLE TUBO RELLENAS DE HORMIGON

    [EN] Concrete-filled steel tubular columns composed of double-tube sections are a recent development. This type of sections are the result of applying a technique used in the construction of immersed tunnels, by forming a sandwich composite section made up of steel-concrete-steel. Apart from the …

    upv Repository record for ESTUDIO NUMÉRICO DE LA CAPACIDAD PORTANTE DE COLUMNAS MIXTAS CON DOBLE TUBO RELLENAS DE HORMIGON (opens in a new tab)

  7. Controlled damage based design of composite structures under seismic loading

    … consisting of circular concrete – filled steel tube columns and composite beams (steel I – beams connected with concrete floor slabs). After an extensive study of the literature review, it is found that there is a lack of a simple simulation of the inelastic hysteretic response for circular …

    greece Repository record for Controlled damage based design of composite structures under seismic loading (opens in a new tab)

  8. Study of thermal performances of falling film absorbers with and without film-inversion

    … processes in both falling film and inter-tube flow regimes. The predictions of the simplified model were compared with those of the detailed numerical model in order to establish the usefulness of the simplified model as a design tool. The semi-empirical models were developed for the …

    nus Repository record for Study of thermal performances of falling film absorbers with and without film-inversion (opens in a new tab) Download file for Study of thermal performances of falling film absorbers with and without film-inversion (opens in a new tab)

  9. Cyclic testing of concrete-filled circular steel tube bridge columns having encased fixed-based detail.

    Concrete-filled steel tube columns have been recognized to have many desirable characteristics that can lead to stable hysteretic energy dissipation during earthquakes. They also have many other properties that make them advantageous for bridge applications (i.e. steel tube provides confinement to …

    ottawa-retro Repository record for Cyclic testing of concrete-filled circular steel tube bridge columns having encased fixed-based detail. (opens in a new tab)

  10. Testing of a New Composite Framing System for Vertical Evacuation Structures

    … new framing system, using concrete filled steel tube columns and piles. The specimen simulated a single bay by single bay frame. Above the inundation depth, a hat truss provides the stiffness; below that the slabs are detailed with break-away connections. There were three study parameters: (i) …

    washington Repository record for Testing of a New Composite Framing System for Vertical Evacuation Structures (opens in a new tab)

  11. Fire Design of Concrete Filled Steel Tube Continuous Column Subjected to Concentric or Eccentric Axial Loading

    … for concrete filled steel tubular (CFST) columns in fire are based on the results of experimental standard fire testing of CFST members where the same temperature is applied to the column over the full column height. However, this is not representative of a CFST column in a typical …

    auckland-ms Repository record for Fire Design of Concrete Filled Steel Tube Continuous Column Subjected to Concentric or Eccentric Axial Loading (opens in a new tab)

  12. Fire behaviour of blind-bolted connections to concrete filled tubular columns under tension

    [EN] Concrete filled steel tubular columns have many advantages in terms of bearing capacity, aesthetics, execution and fire resistance, thanks to the collaborative work of both materials steel and concrete. The effort made in the last decades to rise a high understanding of their behaviour …

    upv Repository record for Fire behaviour of blind-bolted connections to concrete filled tubular columns under tension (opens in a new tab)

  13. Design of One-Story Hollow Structural Section (HSS) Columns Subjected to Large Seismic Drift

    During an earthquake, columns in a one-story building must support vertical gravity loads while undergoing large lateral drifts associated with deflections of the vertical seismic force resisting system and deflections of the flexible roof diaphragm. Analyzing the behavior of these gravity columns …

    vt Repository record for Design of One-Story Hollow Structural Section (HSS) Columns Subjected to Large Seismic Drift (opens in a new tab)

  14. Performance of High-Strength Reinforced Concrete Columns Under Shock-Tube Induced Blast Loading

    … on the blast behaviour of reinforced concrete columns. As part of the study, a total of seventeen reinforced concrete columns with different design combinations of concrete, steel fibers, and steel reinforcement were designed, constructed, and tested under gradually increasing blast loads using …

    ottawa-retro Repository record for Performance of High-Strength Reinforced Concrete Columns Under Shock-Tube Induced Blast Loading (opens in a new tab)

  15. Axial compressive behaviour of FRP-confined high-strength concrete

    External confinement of concrete columns with fibre-reinforced polymer (FRP) sheets has been shown to lead to significant improvements on the axial compressive behaviour of these columns. This application of FRP composites is effective as a confinement material for concrete, in both the seismic …

    adelaide Repository record for Axial compressive behaviour of FRP-confined high-strength concrete (opens in a new tab)