Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Two-phase flow--Measurement."”

  1. Two-Phase Flow Measurement of Geothermal Fluid

    Online, real-time, two-phase fluid measurement of mass flow rate and enthalpy are necessary and important for monitoring individual well performance and for optimum geothermal reservoir management. Existing research on two-phase flow measurements in geothermal applications was examined and the …

    auckland-ms Repository record for Two-Phase Flow Measurement of Geothermal Fluid (opens in a new tab)

  2. Two-Phase Flow Measurement using Fast X-ray Line Detector System

    … mass transfer mechanisms in various gas-liquid flow systems. It becomes critically important to accurately measure void fraction as advanced high fidelity two-phase flow models require high-quality validation data. However, void fraction measurement remains a challenging task to date due to the …

    vt Repository record for Two-Phase Flow Measurement using Fast X-ray Line Detector System (opens in a new tab)

  3. High-Speed Ultrasonic Pulse-Echo System for Two-Phase Flow Measurement

    <p>Two-phase gas-liquid flow in pipes is of great practical importance in the nuclear and petroleum industries, etc. Currently, in thermalhydraulic analysis which requires modelling of a two-phase flow medium, such as boiling liquids, condensing vapors, etc., a variety of computer codes are …

    mcmaster Repository record for High-Speed Ultrasonic Pulse-Echo System for Two-Phase Flow Measurement (opens in a new tab)

  4. Development of a Fast X-ray Line Detector System for Two-Phase Flow Measurement

    Measuring void fraction distribution in two-phase flow has been a challenging task for many decades because of its complex and fast-changing interfacial structure. In this study, a non-intrusive X-ray measurement system is developed and calibrated to mitigate this challenge. This approach has …

    vt Repository record for Development of a Fast X-ray Line Detector System for Two-Phase Flow Measurement (opens in a new tab)

  5. Uncertainty Quantification and Accuracy Improvement of the Double-Sensor Conductivity Probe for Two-Phase Flow Measurement

    … for obtaining local time-averaged parameters in two-phase flows. The uncertainty of this measurement technique has not been well understood in the past as it involves many different steps and influential factors in a typical measurement. This dissertation aims to address this gap by performing a …

    vt Repository record for Uncertainty Quantification and Accuracy Improvement of the Double-Sensor Conductivity Probe for Two-Phase Flow Measurement (opens in a new tab)

  6. Gas-Liquid Two-Phase Flow Metering Using Coriolis Flowmeters

    … describes a novel methodology for the gas-liquid two-phase flow measurement using Coriolis flowmeters incorporating a semi-empirical physical model. A review of methodologies and techniques for the gas-liquid two-phase flow measurement is given, together with the advantages and limitations of …

    kent Repository record for Gas-Liquid Two-Phase Flow Metering Using Coriolis Flowmeters (opens in a new tab)

  7. Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow

    … of a coupled slotted orifice and swirl flow meters, and a coupled slotted orifice and an impedance probe flow meter for multiphase flow is evaluated to develop a new multiphase flow meter. The slotted orifice also provides well homogenized flow for several pipe diameters downstream of …

    tamu Repository record for Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow (opens in a new tab)

  8. Permittivity and Conductivity Imaging in Electrical Capacitance Tomography

    … a tool for process monitoring in particular for two-phase flow measurement. These applications mainly focus on the dielectric samples, whose conductivity is negligibly small. This thesis studies ECT imaging with conductivity considerations. The conductive materials will affect the capacitance …

    bath Repository record for Permittivity and Conductivity Imaging in Electrical Capacitance Tomography (opens in a new tab)

  9. Multiphase Flow Measurement Using Coriolis Flowmeters Incorporating Soft Computing Techniques

    This thesis describes a novel measurement methodology for two-phase or multiphase flow using Coriolis flowmeters incorporating soft computing techniques. A review of methodologies and techniques for two-phase and multiphase flow measurement is given, together with the discussions of existing …

    kent Repository record for Multiphase Flow Measurement Using Coriolis Flowmeters Incorporating Soft Computing Techniques (opens in a new tab)

  10. Special Instrumentation for Two-Phase Flow

    The design of engineering systems, involving two-phase flow, such as nuclear water reactors, requires the ability to model and predict the detailed behavior of those flows and the phenomena that they manifest, with a required degree of accuracy. In the past a significant amount of effort has been …

    poli-torino Repository record for Special Instrumentation for Two-Phase Flow (opens in a new tab)

  11. Pressure Drop Across a Restriction of Annular Geometry

    … obtained for air, water, and the corresponding two-phase mixtures. The loss coefficients associated with these pressure drops were experimentally determined and empirical relations correlating the results were developed. The tests were performed at atmospheric conditions (atmospheric temperature …

    ucf Repository record for Pressure Drop Across a Restriction of Annular Geometry (opens in a new tab)