Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"U values"”.

  1. An investigation into the insitu U values of wall constructions

    … such as workmanship and the relevance of design values in practice. This study provides a useful addition to the otherwise sparse literature of actual measured heat flow and temperature data available from large scale field surveys in UK.A review of methods and equipment used to recover the …

    greece Repository record for An investigation into the insitu U values of wall constructions (opens in a new tab)

  2. Impacts of dynamic U-values of cross-laminated timber (CLT) and conventional building envelopes on building operational energy use

    … influence simulation results. Theoretical U-values have been employed in most related studies. However, the U-values of envelopes fluctuate owing to temperature and relative humidity (T/RH). This means that the dynamic U-values of building envelopes need to be considered in simulations. In …

    whiterose Download PDF for Impacts of dynamic U-values of cross-laminated timber (CLT) and conventional building envelopes on building operational energy use (opens in a new tab)

  3. A Numerical and Experimental Study of Thermal Transmittance of Window Systems

    … thermally broken aluminium frames, the overall U-values are 17 to 112% and 5 to 57% higher than the corresponding centre-of-glass U-values, respectively. The use of these overall U-values instead of the centre-of-glass U-values would enable a more accurate estimate of the energy performance of …

    nus Repository record for A Numerical and Experimental Study of Thermal Transmittance of Window Systems (opens in a new tab) Download file for A Numerical and Experimental Study of Thermal Transmittance of Window Systems (opens in a new tab)

  4. Detrital Zircon Petrochronology for Sedimentary Provenance Analysis: Source to Sink of the Mississippi/Missouri River Drainage Basin

    … chemistry. By combining U-Pb ages and Th/U values of detrital zircon from 13 samples collected from Quaternary sand deposits in the Upper Missouri, Yellowstone, Bighorn, Platte, Kansas, Arkansas, Mississippi, Red and Brazos Rivers, an interpretation of detailed signatures that record …

    mo-state Repository record for Detrital Zircon Petrochronology for Sedimentary Provenance Analysis: Source to Sink of the Mississippi/Missouri River Drainage Basin (opens in a new tab)

  5. The thermal performance solid wall homes in England

    … Guide. Rather than rely solely on experimental values from full thickness walls, a theoretical calculation was used for this revision. The U-value published in the 1970 Guide was equivalent to 2.10 W/m2K. In the 2010s my work measured the U-values of over 300 solid walls in-situ. Fieldwork was …

    westminster Repository record for The thermal performance solid wall homes in England (opens in a new tab) Download PDF for The thermal performance solid wall homes in England (opens in a new tab)

  6. Forecasting Natural Gas Prices Using Time Series Models

    … Being able to accurately predict future CPI-U values is important because it allows portfolio managers and financial institutions to properly adjust their market positions for inflation prior to the CPIs print. Certain bonds, such as Treasury Inflation Protected Securities (TIPS), are indexed …

    cornell Repository record for Forecasting Natural Gas Prices Using Time Series Models (opens in a new tab)

  7. A Survey Measuring The Efficacy Of Duty And Rest Guidelines In Business Aviation Operations

    … total fatigue survey scores. Mann-Whitney U values were found to be statistically significant in five of the nine BA Guidelines criteria between COs and NCOs, with small to medium effect in all cases. Additionally, Mann-Whitney U statistical tests were conducted to compare six operation types …

    nodak Repository record for A Survey Measuring The Efficacy Of Duty And Rest Guidelines In Business Aviation Operations (opens in a new tab)

  8. Analysis of affixed words: Ten selected trade books

    … affixed words having family frequencies with U values equal to or less than 100.00. The range was five affixed words to 28 affixed words having family frequencies with U values equal to or less than 100.00. (3) There was an increase in the percentage of affixed words which were semantically …

    nebraska Repository record for Analysis of affixed words: Ten selected trade books (opens in a new tab)

  9. DESCRIPTION OF POLARONS IN LAYERED TRANSITION METAL OXIDES USING THE r2SCAN DENSITY FUNCTIONAL WITH FULLY NONLOCAL CORRECTIONS AND EFFECT OF STRAIN ON THE BAND GAP OF MONOLAYER MOLYBDENUM DISULFIDE

    … alternative. By selecting appropriate U and Ud values for the d orbitals of host and defect atoms, this method accurately describes defects in materials. Our study on small polaron defects in layered transition-metal oxides demonstrates this. Using literature values for U and Ud, we investigated …

    temple Repository record for DESCRIPTION OF POLARONS IN LAYERED TRANSITION METAL OXIDES USING THE r2SCAN DENSITY FUNCTIONAL WITH FULLY NONLOCAL CORRECTIONS AND EFFECT OF STRAIN ON THE BAND GAP OF MONOLAYER MOLYBDENUM DISULFIDE (opens in a new tab)

  10. Performance Optimisation of Hot Water Cylinders

    … coil within a test cylinder and measuring the U values obtained under operation. In each case the coil tested was placed offset to the cylinder axis with the intention of creating a convective current to improve heat transfer. Special tests separate from the parametric investigation were also …

    whiterose Download PDF for Performance Optimisation of Hot Water Cylinders (opens in a new tab)

  11. A cost analysis study of the benefits of building energy code upgrades in Iowa

    … tape and for installing windows with higher U-values as specified in 2000 IECC. The reduced energy consumption for heating and cooling for 2000 IECC homes compared to homes built to lesser standards was determined for a range of home styles and sizes. The annual energy consumption along with …

    iastate Repository record for A cost analysis study of the benefits of building energy code upgrades in Iowa (opens in a new tab)

  12. Characteristics of atmospheric forcing functions.

    … all three stations, about 20$ of the largest u^ values contribute 50% of the accumulated u*3 and 50% account for 17$ of the total at each station. Synoptic forcing events are defined as sustained periods during which the daily mean forcing exceeds the long-term mean. Between 68 and 75% of the …

    nps Repository record for Characteristics of atmospheric forcing functions. (opens in a new tab)

  13. An investigation of job satisfaction, life satisfaction and intention to turnover

    … full-time employee sample. The total <u>F</u> values were all significant, <u>p</u> < .01. The three hypotheses were only slightly supported in the RA sample as only one dependent measure was significant.</p><p>Implications for future research on job satisfaction, life satisfaction and turnover …

    ut-knoxville Repository record for An investigation of job satisfaction, life satisfaction and intention to turnover (opens in a new tab)

  14. The mechanism of the activity of lysozyme on bacteria

    … and on both substrates. The similarity of "u" values indicates that the lyzing action of lysozyme is characteristic of the enzyme on both substrates. It appears that the lysozyme is splitting the same type of linkage in the mucopolysaccharide component of the bacterial cell membrane. Thus this …

    bu Repository record for The mechanism of the activity of lysozyme on bacteria (opens in a new tab)

  15. Quantitative thermal performance assessment of building envelopes – emergent practices and infrared thermography

    … 2 to Chapter 4), thermal transmittances (U-values) of wall assemblies were estimated with external IRT and compared with 3D computer simulations. Furthermore, the impact of the accuracy of U-values estimated with IRT on the deviation of energy simulation outputs with metered data was …

    uvic Repository record for Quantitative thermal performance assessment of building envelopes – emergent practices and infrared thermography (opens in a new tab)

  16. From Continental Margins to the Deep Ocean

    … On the Peruvian Margin, elevated FeHR/FeT and U values are influenced by terrigenous input and lateral transport, not solely redox conditions. After accounting for these effects, clearer patterns emerge. At Site 680, Mo accumulation varied over ~620 kyr, with particulate control during …

    cau-kiel Repository record for From Continental Margins to the Deep Ocean (opens in a new tab)

  17. Bottom-up characterisation of the Italian residential building stock - Archetype buildings and energy demand

    … of the model, which are: HW, SW, Trmin, U-­‐values. This work contributes to a European building stock database, and will be used as a basis to assess the effects of measures related to the energy efficiency and energy savings.

    chalmers Repository record for Bottom-up characterisation of the Italian residential building stock - Archetype buildings and energy demand (opens in a new tab)

Page 1 of 3