Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 39 for “"U-bend"”.
-
The Vibro-Impact Response of Heat Exchanger U-Bend Tubes with Flat Bar Supports
A theoretical study has been conducted to investigate the effect of flat bars supports on the dynamic response of a heat exchanger U-tube. The tube is modelled using three dimensional, six degrees of freedom per node straight beam finite elements. A new method, the stiffness method, is introduced …
-
Evaluation of High Temperature Borehole Heat Exchangers for Thermal Energy Storage
… were tested. Two heat exchangers used a U-bend geometry, and another used a coaxial pipe. The heat exchangers were placed in an apparatus made from a steel drum filled with sand and heated with fluid temperatures of 40-60ºC. One of the U-bend heat exchangers was surrounded by a borehole …
-
The effect of surface condition on aqueous corrosion and environmental embrittlement of iron aluminides
… cleaned and chemically cleaned surfaces. U-bend tests were conducted to see how either a 750°C oxide surface or a mechanically cleaned surface affected hydrogen embrittlement. At E<sub>corr</sub> neither surface condition produced cracking in the U-bend specimens. At the hydrogen charging …
-
The effect of nitrogen content on the susceptibility to stress-corrosion cracking of type 20Cr-20Ni and AISI type 310 stainless steels
… cracking were studied by exposing the U-bend specimens of the alloys containing various nitrogen levels to magnesium chloride solutions boiling at 154°C. It was found that the increase in nitrogen levels up to 0.161 wt.% did not induce cracking in type 20Cr-20Ni alloys even after long …
-
Numerical investigation of the fluidelastic instability of two-phase flow in a parallel triangular tube array
… yet the phenomenon is not well understood. The U-bend region of the steam generator is very prone to the FEI and the flow in this region is characterized by a two-phase nature. Most studies of this phenomenon have been carried out experimentally on specific tube arrays at certain conditions, and …
-
Numerical and Experimental Design of Coaxial Shallow Geothermal Energy Systems
… energy from shallow depths. Traditionally, U-bend systems, which consist of two one-inch pipes with a U-bend connector at the bottom, have been widely used in geothermal applications. Alternative systems include coaxial pipes (pipe-in-pipe) that are the main focus of this research. It has been …
-
Stress Corrosion Cracking Resistance of Martensitic Stainless Steels for Transmutation Applications
… rate testing (SSR) techniques. C-ring and U-bend specimens have also been tested in the acidic solution. The effect of hydrogen on the cracking susceptibility has been evaluated under controlled cathodic potential. While no failures were observed with smooth specimens at constant load, the …
-
Investigation of Chloride-induced Stress Corrosion Cracking for Long-Term Storage of Spent Nuclear Fuel in Dry Storage Systems
… to examine 304 and 304L stainless steel U-bend and welded U-bend samples. The samples were exposed to chloride rich and humid fogging in a corrosion chamber at 35℃ continuously for 4 weeks, 8 weeks, and 12 weeks. The same experiment was repeated at 50℃ for 4 weeks, 8 weeks, and 14 weeks to …
-
Wall Modeled Large-Eddy Simulations in Rotating Systems for Applications to Turbine Blade Internal Cooling
… _b = 49,000, and two-pass smooth duct with a U-bend at ã Reã _b = 25,000 for ã Roã _b = 0 to 0.238 against WRLES and experimental data. In addition, for the two-pass smooth duct with a U-bend simulations, the synthetic eddy method (SEM) is used to artificially generate eddies at the inlet based …
-
Investigation of a U-shaped fuel cell flow channel with particle image velocimetry (PIV)
… separating from the sharp convex comers of the U-bend and reattaching on downstream surfaces. The flow also exhibits the classical secondary Dean flow pattern with two symmetric circulation zones. Transition takes place in the range 381 I Re I 436 as the two recirculation zones, which originally …
-
Aqueous corrosion and environmentally assisted cracking characteristics of iron aluminides
… cracking were also investigated using U-bend and slow-strain-rate tests. U-bend SCC evaluations were conducted on two iron aluminides in acid-chloride (pH=4, 200 ppm Cl<sup>-</sup>), thiosulfate, and tetrathionate solutions at the freely-corroding conditions. Cracking failures occurred in …
-
Effect of pre-exposure thermal treatment on susceptibility of type 304 austenitic stainless steel to stress corrosion
… nucleation and rate of crack propagation. U-bend specimens were exposed to 42 weight percent magnesium chloride aqueous solution after pre-exposure heat treatments at 140°C and 154°C. The straight-line relationship between maximum crack depth and the logarithm of exposure time expressed by …
-
Heat Transfer at Turn Portion of Rotating Multi-Pass Internal Cooling Channels of Gas Turbine Blades
… internal cooling channel with a 180° U-bend at the hub turn portion. The flow is radially inward at the second passage, while it is radially outward at the third passage after the U-bend. Measurement was conducted at the second and the third passages. Aspect ratio of the second passage …
-
Environment Assisted Cracking of Target Structural Materials Under Different Loading Conditions
… slow strain rate (SSR) conditions. C-ring and U-bend specimens have also been tested for stress corrosion cracking evaluation in the acidic solution. The role of hydrogen on the cracking tendency has been evaluated by cathodic applied potential. The results of constant load testing enabled the …
-
Tensile deformation, corrosion and crack-growth characterization of a nickel-base alloy
… (DCB) specimens. C-ring and U-bend specimens did not show any cracking in an acidic solution. The cylindrical specimens, used in tensile and environmental-cracking studies, showed ductile failures.
-
Metallurgical and corrosion characterization of structural materials for S-I cycle
… No cracking was observed with C-ring and U-bend specimens of Alloy C-22 in a similar environment at 150°C. The corrosion rate of Alloy C-22 was gradually reduced for exposure up to 28 days followed by an enhancement at a longer duration. The characterization of primary fracture surface of …
-
THE EFFECT OF H2SO4 SURFACE PRE-TREATMENT ON THE STRESS CORROSION CRACKING OF MAGNESIUM ALLOY AZ31B
… with respect to surface condition. Salt fog U-bend testing was used to identify changes in SCC as a result of surface conditioning pre-treatments. Six surface conditions were investigated: as-received, mechanically-polished, sulphuric acid (H2SO4)-cleaned, mechanically-polished then …
-
An Experimental Rig and Investigation of Steam Generator Tube Loading during Main Steam Line Break
… of secondary side coolant, particularly in the U-bend region. Such tube vibrations result in fretting wear at tube supports, reducing the margin of safety against failure. In the event of a main steam-line- break, the superheated water In the steam generator undergoes rapid depressurisation, …
-
Heat Storage Using High Temperature Borehole Heat Exchangers
… A variety of BHE designs were evaluated and U-Bend and coaxial closed-loop-pipe designs were selected for testing in the laboratory. The thermal resistance between the fluid piping and borehole wall, known as borehole thermal resistance (BTR), was used to evaluate each design. While the …
-
Evaluation of two-phase evaporation pressure drop correlations for low refrigerant mass flux.
… ranging from 0.186 to 0.317 inches, U-bend internal radii ranging from 0.342 to 0.750 inches in horizontal and vertical orientations of evaporators. The geometry of the samples closely resembled a commonly used serpentine shape with multiple U-bends experiencing both, up- and down-flow …
Page 1 of 2