Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 75 for “"UV Disinfection"”.

  1. UV Disinfection between Concentric Cylinders

    … of the most resistant pathogens. Ultraviolet (UV) disinfection is one of the promising methods to reach this 5-log reduction of pathogens. The absorption coefficients of juices typically vary from 10 to 40 1/cm and can be even higher depending on brand and processing conditions. Thin film …

    gatech Repository record for UV Disinfection between Concentric Cylinders (opens in a new tab)

  2. Characterization and UV disinfection of tropical bacteria in ambient air

    … of biological contamination. Ultraviolet (UV) radiation with titanium dioxide (TiO2) as a photocatalyst is considered as the effective way to destroy biological contaminants because of its ability for complete degradation of the pollutants. However, very little information exists in …

    nus Repository record for Characterization and UV disinfection of tropical bacteria in ambient air (opens in a new tab)

  3. Experimental and Theoretical Study of a UV Disinfection System for Water Treatment

    An innovative energy saving ultraviolet disinfection reactor has been developed and tested. The technical approach taken is to establish a relationship between the power consumption and the design features of a UV disinfection system, and then determine these design features by minimizing the power …

    rit Repository record for Experimental and Theoretical Study of a UV Disinfection System for Water Treatment (opens in a new tab)

  4. The Effect of Physicochemical Properties of Secondary Treated Wastewater Flocs on UV Disinfection

    … shield microbes from exposure to ultraviolet (UV) light, and decrease the efficiency of disinfection, causing the tailing phenomena. This thesis investigates whether the formation of compact cores within flocs induces higher levels of UV resistance. Moreover, it investigates the effect of …

    toronto-retro Repository record for The Effect of Physicochemical Properties of Secondary Treated Wastewater Flocs on UV Disinfection (opens in a new tab)

  5. Analysis of Ultraviolet Energy Distribution in UV Disinfection Systems Using Monte Carlo Ray -Trace method

    Determination of fluence rate in ultraviolet (UV) disinfection systems is a crucial part in evaluating disinfection efficiency of the systems. A robust Monte Carlo Ray Trace (MCRT) method has been developed to determine fluence rates in three-dimensional space of the systems. This is a statistical …

    odu Repository record for Analysis of Ultraviolet Energy Distribution in UV Disinfection Systems Using Monte Carlo Ray -Trace method (opens in a new tab)

  6. The Effect of Physicochemical Properties of Wastewater Flocs on UV Disinfection Following Hydrodynamic Particle Breakage

    … had potential as a method to help improve the disinfection of wastewater effluents. The physicochemical properties of flocs from four distinct effluents sources (combined sewer overflow, settled combined sewer overflow, primary effluent, and final effluent) were compared before and after …

    guelph Repository record for The Effect of Physicochemical Properties of Wastewater Flocs on UV Disinfection Following Hydrodynamic Particle Breakage (opens in a new tab)

  7. An investigation of UV disinfection performance under the influence of turbidity & particulates for drinking water applications

    UV disinfection performance was investigated under the influence of representative particle sources, including wastewater particles from secondary effluent in a wastewater treatment plant, river particles from surface water, floc particles from coagulated surface water, floc particles from …

    waterloo Repository record for An investigation of UV disinfection performance under the influence of turbidity & particulates for drinking water applications (opens in a new tab)

  8. Computational fluid dynamics and experimental studies of an energy-efficient UV disinfection system for water treatment

    In typical commercial UV treatment system, water is flushed through a reactor vessel, where a UV lamp irradiates the flowing water. The distribution of the UV dose is extremely non-uniform. At distances away from the light, the dosage will be too low to kill the microorganism. As a result more …

    rit Repository record for Computational fluid dynamics and experimental studies of an energy-efficient UV disinfection system for water treatment (opens in a new tab)

  9. Effect of transmittance and suspended soils on the efficacy of UV disinfection of bacterial contaminants in water

    … robust and quantitative data on the influence of UV absorption and suspended solids on UV disinfection an experimental study using commercial disinfection technology was undertaken.

    adelaide Repository record for Effect of transmittance and suspended soils on the efficacy of UV disinfection of bacterial contaminants in water (opens in a new tab)

  10. DEVELOPMENT OF A TWO-STAGE LED-UV DISINFECTION SYSTEM: INACTIVATION PERFORMANCE, MOLECULAR MECHANISMS AND IMPACT OF WATER MATRIX

    LED UV, WHICH IS MERCURY FREE AND THEORETICALLY MORE ENERGY EFFICIENT, HAS NOW BECOME AN ALTERNATIVE TO CONVENTIONAL UV LAMPS IN WATER DISINFECTION INDUSTRY. IN THIS RESEARCH, THE DISINFECTION PERFORMANCE OF A NOVEL SEQUENTIAL LED UVA AND LED UVC PROCESS WAS EVALUATED. THE RESULTS REVEALED THAT …

    nus Repository record for DEVELOPMENT OF A TWO-STAGE LED-UV DISINFECTION SYSTEM: INACTIVATION PERFORMANCE, MOLECULAR MECHANISMS AND IMPACT OF WATER MATRIX (opens in a new tab)

  11. Ultraviolet disinfection kinetics for potable water production.

    Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV …

    adelaide Repository record for Ultraviolet disinfection kinetics for potable water production. (opens in a new tab)

  12. Ultraviolet disinfection of unfiltered water supplies : exploring effects of particle-microorganism association and efficiency enhancement strategies

    … interactions on ultraviolet (UV) disinfection performance, identify water quality indicators that best describe performance, and suggest innovative methodologies to mitigate these effects on disinfection performance. Several sampling points of two full-scale treatment plants, …

    ubc Repository record for Ultraviolet disinfection of unfiltered water supplies : exploring effects of particle-microorganism association and efficiency enhancement strategies (opens in a new tab)

  13. Effects of UV Light Disinfection on Tetracycline Resistant Bacteria in Wastewater Effluents

    … of this study was to investigate the effect of UV light disinfection on ARGs and antibiotic resistant bacteria. Wastewater effluent samples from a wastewater treatment plant (WWTP) in Texas were evaluated for differences in abundance and diversity of tetracycline resistant bacteria before and …

    tamu Repository record for Effects of UV Light Disinfection on Tetracycline Resistant Bacteria in Wastewater Effluents (opens in a new tab)

  14. Investigation of Factors that Limit Efficacy of Ultraviolet Disinfection in Water and Wastewater Treatment

    … of factors that limit and hinder ultraviolet (UV) disinfection efficacy, specifically the presence of flocs, and self-aggregation, regrowth and reactivation of microorganisms (Chapters 1 and 2). Chapter 4 aimed to provide an in-depth understanding of the effect of particles and flocs on UV …

    carleton Repository record for Investigation of Factors that Limit Efficacy of Ultraviolet Disinfection in Water and Wastewater Treatment (opens in a new tab)

  15. Two-step granular activated carbon filtration in drinking water treatment

    … after installing two-step GAC filtration and UV disinfection was evaluated. The study revealed that the major factors influencing the effective NOM removal in GAC filtration are the choice of GAC type and the frequency of regeneration. Other factors, such as empty bed contact time and …

    aalto Repository record for Two-step granular activated carbon filtration in drinking water treatment (opens in a new tab)

  16. Virus inactivation by silver doped titanium dioxide nanoparticles for drinking water treatment

    UV disinfection of drinking water is becoming more common as water utilities attempt to control the formation of disinfection byproducts. While most organisms are readily inactivated by UV, certain viruses require a large fluence for adequate disinfection. In this study, photocatalytic silver doped …

    rice Repository record for Virus inactivation by silver doped titanium dioxide nanoparticles for drinking water treatment (opens in a new tab)

  17. Assessment of Effective Solids Removal Technologies to Determine Potential for Vegetable Washwater Reuse

    … DAF is able to produce waters with higher UV transmittance and can work better with membrane filtration and UV disinfection. While centrifuge showed higher reduction in pathogen levels, it can be cost effective and compact in design. Membrane filtration feasibility showed that high quality …

    guelph Repository record for Assessment of Effective Solids Removal Technologies to Determine Potential for Vegetable Washwater Reuse (opens in a new tab)

  18. Kinetic Modeling of Microbial Inactivation by Ultraviolet Light

    Ultraviolet (UV) light reactors are currently being designed for the disinfection of water and wastewater. However, little information is available relating the effects of mixing, light intensity, reaction time, and water quality to UV disinfection efficiency. This study was designed to develop …

    uiuc Repository record for Kinetic Modeling of Microbial Inactivation by Ultraviolet Light (opens in a new tab)

  19. The Formation of Halonitromethanes in Wastewater Treatment Plant Effluents

    Disinfection by-products (DBPs) have been a water treatment concern since their discovery in the 1970's. Today, only eleven drinking water DBPs are regulated by the Environmental Protection Agency (EPA). However, over 500 DBPs have been identified in drinking waters with advances in analytical …

    clemson Repository record for The Formation of Halonitromethanes in Wastewater Treatment Plant Effluents (opens in a new tab)

Page 1 of 4