Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Ultra-High field MRI"”.

  1. Deep Learning Methods for Ultra High Field MRI

    Ultra-high field (UHF) magnetic resonance imaging (MRI) provides increased signal-to-noise ratio (SNR) and the potential for higher spatial resolution, but also introduces significant challenges. Two of the most critical issues at UHF are the inhomogeneity of the transmit radiofrequency (B₁⁺) …

    umn Repository record for Deep Learning Methods for Ultra High Field MRI (opens in a new tab)

  2. RF and electronic design perspective on ultra-high field MRI systems

    Magnetic Resonance Imaging (MRI) is one of the most sophisticated technologies to produce detailed images of the human body's organs and structures. There were many items of pioneering work in MRI over the last few decades. However, many challenges still remain. This dissertation includes two …

    umn Repository record for RF and electronic design perspective on ultra-high field MRI systems (opens in a new tab)

  3. Decoupling methods for radio frequency antennas in ultra-high-field MRI

    … (RFID), wireless power transfer (WPT), and ultra-high-field magnetic resonance imaging (UHF MRI), decoupling of closely located antennas without significant changes of radiation pattern is a key task. In magnetic resonance imaging, there is a trend to increase the magnetic field strengths to …

    aalto Repository record for Decoupling methods for radio frequency antennas in ultra-high-field MRI (opens in a new tab)

  4. Developing RF safety strategies at high field and ultra-high field MRI

    … (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients …

    umn Repository record for Developing RF safety strategies at high field and ultra-high field MRI (opens in a new tab)

  5. Developing RF safety strategies at high field and ultra-high field MRI

    … (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for patients …

    umn Repository record for Developing RF safety strategies at high field and ultra-high field MRI (opens in a new tab)

  6. Lesion analysis from ultra-low to ultra-high field MRI in multiple sclerosis

    Ultra-high field (UHF) and ultra-low field (ULF) magnetic resonance imaging (MRI) offer complementary approaches for studying and monitoring white matter lesions (WMLs) in multiple sclerosis (MS). UHF MRI provides enhanced sensitivity to chronic lesion pathology, while ULF MRI enables portable and …

    oxford Repository record for Lesion analysis from ultra-low to ultra-high field MRI in multiple sclerosis (opens in a new tab)

  7. High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI

    Quantitative MRI (qMRI) aims to directly estimate tissue parameters rather than obtain images weighted on them, enhancing reproducibility of the results. However, long acquisition times have hampered its translation to clinics. Many methods have been proposed to make acquisitions more efficient, …

    kings Repository record for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab) Download PDF for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab)

  8. Investigating the biological impact of light on brain function using 7T ultra-high field MRI

    … areas of the brain, we utilised two techniques, ultra-high-field 7 Tesla (7T) functional magnetic resonance imaging (fMRI) and infrared eye tracking equipment. Young healthy adults completed an fMRI protocol with simultaneous eye tracking whilst exposed to the light of various illuminance and …

    liege Repository record for Investigating the biological impact of light on brain function using 7T ultra-high field MRI (opens in a new tab) Download PDF for Investigating the biological impact of light on brain function using 7T ultra-high field MRI (opens in a new tab)

  9. Investigation of Collagen Fiber Crimp Morphology and Microstructural Organization in Annulus Fibrosus by Ultra High-Field MRI

    … microstructure within healthy bovine AF by ultra high-field (9.4T) magnetic resonance imaging (MRI). Collagen crimp and trans lamellar cross bridges were detected along surface and interior AF. Fiber bundles were also shown to reorient following circumferential tension. Together, an MRI …

    calgary Repository record for Investigation of Collagen Fiber Crimp Morphology and Microstructural Organization in Annulus Fibrosus by Ultra High-Field MRI (opens in a new tab)

  10. Ultra-high Field MRI Methods for Precise Anatomical and Spectroscopic Measurements in the Brain and Application to Neurological and Neuropsychiatric Diseases

    … multiple diseases. Magnetic resonance imaging (MRI) is a noninvasive imaging technique which facilitates detection of brain lesions and visualization of the brain overall. However, limitations in contrast and resolution at clinical field strengths may hinder investigation of the underlying …

    cuny Repository record for Ultra-high Field MRI Methods for Precise Anatomical and Spectroscopic Measurements in the Brain and Application to Neurological and Neuropsychiatric Diseases (opens in a new tab)

  11. Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla

    Magnetic resonance imaging (MRI) at the magnetic field strength of 7 Tesla (7T) enhances the quality of images available for research and clinical use. The improvements are however accompanied by novel challenges that are specific to ultra high-field MRI, which includes field strengths of 7T and …

    glasgow Repository record for Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla (opens in a new tab) Download PDF for Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla (opens in a new tab)

  12. Applications of parallel radiofrequency transmission to ultra-high-field magnetic resonance imaging

    <p>Increasing the static magnetic field (B0) strength of magnetic resonance imaging (MRI) scanners improves the signal-to-noise ratio (SNR). Higher SNR may be used for more sensitive, faster, and higher resolution imaging.</p> <p>Despite its potential, the biggest challenges for ultra-high field …

    oxford Repository record for Applications of parallel radiofrequency transmission to ultra-high-field magnetic resonance imaging (opens in a new tab)

  13. Magnetic Resonance Based Electrical Properties Tomography (Ept) Using Multi-Channel Transmission For Imaging Human Brain And Animal Cancer Models

    … effects of electromagnetic radiation involved in MRI exams as well as wireless communication. In this dissertation, non-invasive EP imaging methods are proposed based on inverse problems using a plurality of radiofrequency electromagnetic field maps (B1 maps) acquired with ultra-high-field MRI. …

    umn Repository record for Magnetic Resonance Based Electrical Properties Tomography (Ept) Using Multi-Channel Transmission For Imaging Human Brain And Animal Cancer Models (opens in a new tab)

  14. Modeling and Simulation of RF Array Systems for Ultra-High Field Magnetic Resonance Imaging

    Magnetic resonance imaging (MRI) has opened up new possibilities in diagnosing and treating many musculoskeletal disorders. MRI has an advantage over other imaging modalities in detecting defects in the bones and soft tissues. New MRI techniques with ultra-high field strengths (7T and above) have …

    buffalo Repository record for Modeling and Simulation of RF Array Systems for Ultra-High Field Magnetic Resonance Imaging (opens in a new tab)

  15. Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength

    … to standard clinical magnetic resonance imaging (MRI) scanners, which are often operated at a field strength of 1.5 or 3 Tesla (T), a higher resolution and subsequent cardiac parameter quantification could potentially be achieved at ultra-high field, i.e., 7 T and above. Unique insights into the …

    wurz-thes Repository record for Methods for Homogenization of Spatio-Temporal B\(_0\) Magnetic Field Variations in Cardiac MRI at Ultra-High Field Strength (opens in a new tab)

  16. Imaging cerebrovascular health using 7T MRI

    … as well as the required scan times.</p> <p>Ultra-high field 7T MRI offers increased signal-to-noise ratio and desirable changes in relaxation parameters, therefore promising substantial improvements to existing neurovascular MRI approaches such as MR angiography (MRA) and MR vessel wall …

    oxford Repository record for Imaging cerebrovascular health using 7T MRI (opens in a new tab)

  17. Quantitative Evaluation of High Impedance Microstrip Array for Ultrahigh Field MR Imaging

    … and treated using magnetic resonance imaging (MRI). When it comes to finding problems in the bones and soft tissues, MRI has an advantage over other imaging modalities. In recent years, new MRI methods with ultra-high field strengths (7T and higher) have been developed. Compared to ultra-high …

    buffalo Repository record for Quantitative Evaluation of High Impedance Microstrip Array for Ultrahigh Field MR Imaging (opens in a new tab)

Page 1 of 2