Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 32 for “"Ultracold neutrons"”.
-
Detecting high rates of ultracold neutrons and thermal neutron production
The first phase of the TRIUMF ultracold advanced neutron source (TUCAN) is operational at TRIUMF in Vancouver, Canada, with the second phase scheduled to be completed in 2020. The first proposed experiment with the source is a neutron electric dipole moment (nEDM) measurement. Preparing the …
-
XPS evaluation of diamond-like-carbon for ultracold neutrons guides
… electric dipole moment (nEDM). The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration aims to improve this precision by an order of magnitude, potentially discovering a non-zero nEDM. This ambitious goal requires a hundredfold increase in ultracold neutron (UCN) statistics compared to …
-
Development of a Novel Beam-Type Neutron Lifetime Experiment Using Ultracold Neutrons
… by the Particle Data Group is taken from ultracold neutron (UCN) measurements, a separate class of experiments suggest a value in four sigma disagreement, meriting further study. The goal of the UCNProBe experiment at Los Alamos National Laboratory is to measure the neutron lifetime using …
-
Thin Films for the Transport of Polarized Ultracold Neutrons for Fundamental Symmetry Study
The use of ultracold neutrons (UCN) to study fundamental parameters such as the neutron lifetime and decay correlations in polarized neutron beta decay are poised to make significant contributions to our understand of the Standard Model and its extensions. To this end, the UCNA experiment is …
-
Determination of the Neutron Beta-Decay Asymmetry Parameter <em>A</em> Using Polarized Ultracold Neutrons
… β-decay asymmetry parameter A0 using polarized ultracold neutrons (UCN). A0 , which represents the parity-violating angular correlation between the direction of the initial neutron spin and the emitted decay electron’s momentum, determines λ = gA /gV , the ratio of the weak axial-vector and …
-
Polarized Ultracold Neutrons: their transport in diamond guides and potential to search for physics beyond the standard model
Experiments with polarized "ultracold neutrons" (UCN) offer a new way to measure the decay correlations of neutron beta decay; these correlations can be used to test the completeness of the Standard Model and predict physics beyond it. Ultracold neutrons are very low energy neutrons that can be …
-
THE NUTS AND BOLTS OF THE NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT AT LOS ALAMOS NATIONAL LABORATORY
… Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey’s method of separated oscillatory fields to search for a nEDM with a statistical uncertainty of 2 × 10−27e cm in 5 calendar years of running. This dissertation presents the following: (1) a description of the LANL …
-
A Measurement of Neutron Polarization and Transmission for the nEDM@SNS Experiment
… combines the unique properties of polarized Ultracold Neutrons (UCN), polarized <sup>3</sup>He, and superfluid <sup>4</sup>He. The experiment will employ a cryogenic magnet and magnetic shielding package to provide the magnetic field environment required to achieve the proposed sensitivity. …
-
Simulations of Electron Detection Systematic Errors for a UCNA+ Experiment
The Ultracold Neutron Asymmetry+ (UCNA+) experiment at the Los Alamos Neu- tron Science Center (LANSCE) Ultracold Neutron source is an upgrade of the UCNA experiment, designed to measure the neutron beta decay asymmetry parameter, A 0 , with a precision of less than 0.2% using polarized ultracold …
-
Magnetic Spin Transport Coils for the n2EDM Experiment
… polarization transfer efficiency of 99\% for ultracold neutrons entering or exiting the precession chamber is required, placing a stringent requirement on the adiabaticity of the magnetic field taper in the neutron guide system. The spin transport fields transition from 5~T (longitudinal) in …
-
Modeling He-II cryostat performance and characterization of spin manipulation components for a neutron electric dipole moment experiment at TRIUMF
This thesis chronicles measurements of ultracold neutrons (UCN) performed at TRIUMF in fall 2018 and fall 2019. Heat response data of the UCN source bottle was taken by measuring its temperature using the vapour pressure of the 4He. The time-dependence of the He-II bottle temperature is …
-
MEASUREMENTS OF THE BINDING ENERGIES OF IONS ON PLASTIC SURFACES IN LIQUID NITROGEN
… plans to increase neutron density by storing ultracold neutrons in superfluid helium-4. In this experiment, the central part of the apparatus consists of two deuterated tetraphenyl butadiene (dTPB) coated poly(methyl methacrylate) (PMMA) cells, which are sandwiched between grounded and …
-
Characterization of the magnetically shielded room for the neutron electric dipole moment experiment at TRIUMF
… |dn| < 1.8 × 10^−26 e·cm (90% C.L.). The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration aims to improve this by an order of magnitude, targeting σ(dn) ≤ 10^−27 e·cm. The standard method for nEDM measurement uses polarized Ultracold Neutrons (UCN) and the Ramsey technique of separated …
-
A Magneto-Gravitational Neutron Trap for the Measurement of the Neutron Lifetime
… measurements of the neutron lifetime used ultracold neutrons (UCN) confined in material bottles. In a material bottle experiment, UCN are loaded into the apparatus, stored for varying times, and the surviving UCN are emptied and counted. These measurements are in poor agreement with …
-
Studies of ultracold neutron dynamics and systematic effects for the TUCAN EDM experiment
The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration is developing a new measurement of the neutron electric dipole moment (nEDM) with the goal of improving the current best limit of dn ≤ 1.8 × 10-²⁶ ecm (90% C.L.) to the level of dn ≲ 2 × 10-²⁷ ecm (90% C.L.). A non-zero nEDM requires the …
-
Magnetic fields and ultracold neutron production: studies towards the neutron electric dipole moment experiment at TRIUMF
… experimental method to measure the nEDM uses the ultracold neutrons (UCN) and employs the Ramsey method of separated oscillatory fields. In this method, the Larmor precession frequency of UCN is measured in the presence of aligned Electric and Magnetic fields orientations. Such precision …
-
Guiding fields development for the TUCAN nEDM Experiment
… The TUCAN nEDM experiment requires polarized ultracold neutrons to be stored in a volume with precisely known electromagnetic fields. To achieve high counting statistics, a large number of neutrons and high degree of neutron polarization are required. For this, the neutron polarization needs …
-
Polarization and two-photon spectroscopy of xenon for optical magnetometry
… will occupy the same experimental volume as ultracold neutrons and be used to measure drifts in an applied magnetic field. A scheme is described for optical magnetometry which involves the production of polarized ¹²⁹Xe followed by measurements using two-photon laser induced fluorescence as a …
-
Magnetic Field Monitoring in the SNS Neutron EDM Experiment
… signal CP violation. To look for an nEDM, stored ultracold neutrons are placed in parallel and anti-parallel magnetic and electric fields and the Larmor precession frequency is carefully measured. A difference in the precession frequency of the neutrons in the two states of the fields would signal …
Page 1 of 2