  1. Detecting high rates of ultracold neutrons and thermal neutron production

    The first phase of the TRIUMF ultracold advanced neutron source (TUCAN) is operational at TRIUMF in Vancouver, Canada, with the second phase scheduled to be completed in 2020. The first proposed experiment with the source is a neutron electric dipole moment (nEDM) measurement. Preparing the …

    manitoba Repository record for Detecting high rates of ultracold neutrons and thermal neutron production (opens in a new tab)

  2. XPS evaluation of diamond-like-carbon for ultracold neutrons guides

    … electric dipole moment (nEDM). The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration aims to improve this precision by an order of magnitude, potentially discovering a non-zero nEDM. This ambitious goal requires a hundredfold increase in ultracold neutron (UCN) statistics compared to …

    manitoba Repository record for XPS evaluation of diamond-like-carbon for ultracold neutrons guides (opens in a new tab)

  3. Development of a Novel Beam-Type Neutron Lifetime Experiment Using Ultracold Neutrons

    … by the Particle Data Group is taken from ultracold neutron (UCN) measurements, a separate class of experiments suggest a value in four sigma disagreement, meriting further study. The goal of the UCNProBe experiment at Los Alamos National Laboratory is to measure the neutron lifetime using …

    uky-thes Repository record for Development of a Novel Beam-Type Neutron Lifetime Experiment Using Ultracold Neutrons (opens in a new tab)

  4. Thin Films for the Transport of Polarized Ultracold Neutrons for Fundamental Symmetry Study

    The use of ultracold neutrons (UCN) to study fundamental parameters such as the neutron lifetime and decay correlations in polarized neutron beta decay are poised to make significant contributions to our understand of the Standard Model and its extensions. To this end, the UCNA experiment is …

    vt Repository record for Thin Films for the Transport of Polarized Ultracold Neutrons for Fundamental Symmetry Study (opens in a new tab)

  5. Determination of the Neutron Beta-Decay Asymmetry Parameter <em>A</em> Using Polarized Ultracold Neutrons

    … β-decay asymmetry parameter A0 using polarized ultracold neutrons (UCN). A0 , which represents the parity-violating angular correlation between the direction of the initial neutron spin and the emitted decay electron’s momentum, determines λ = gA /gV , the ratio of the weak axial-vector and …

    uky-thes Repository record for Determination of the Neutron Beta-Decay Asymmetry Parameter <em>A</em> Using Polarized Ultracold Neutrons (opens in a new tab)

  6. Polarized Ultracold Neutrons: their transport in diamond guides and potential to search for physics beyond the standard model

    Experiments with polarized "ultracold neutrons" (UCN) offer a new way to measure the decay correlations of neutron beta decay; these correlations can be used to test the completeness of the Standard Model and predict physics beyond it. Ultracold neutrons are very low energy neutrons that can be …

    vt Repository record for Polarized Ultracold Neutrons: their transport in diamond guides and potential to search for physics beyond the standard model (opens in a new tab)

  7. THE NUTS AND BOLTS OF THE NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT AT LOS ALAMOS NATIONAL LABORATORY

    … Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey’s method of separated oscillatory fields to search for a nEDM with a statistical uncertainty of 2 × 10−27e cm in 5 calendar years of running. This dissertation presents the following: (1) a description of the LANL …

    iu Repository record for THE NUTS AND BOLTS OF THE NEUTRON ELECTRIC DIPOLE MOMENT EXPERIMENT AT LOS ALAMOS NATIONAL LABORATORY (opens in a new tab)

  8. A Measurement of Neutron Polarization and Transmission for the nEDM@SNS Experiment

    … combines the unique properties of polarized Ultracold Neutrons (UCN), polarized <sup>3</sup>He, and superfluid <sup>4</sup>He. The experiment will employ a cryogenic magnet and magnetic shielding package to provide the magnetic field environment required to achieve the proposed sensitivity. …

    utk-theses Repository record for A Measurement of Neutron Polarization and Transmission for the nEDM@SNS Experiment (opens in a new tab)

  9. Simulations of Electron Detection Systematic Errors for a UCNA+ Experiment

    The Ultracold Neutron Asymmetry+ (UCNA+) experiment at the Los Alamos Neu- tron Science Center (LANSCE) Ultracold Neutron source is an upgrade of the UCNA experiment, designed to measure the neutron beta decay asymmetry parameter, A 0 , with a precision of less than 0.2% using polarized ultracold …

    uky-thes Repository record for Simulations of Electron Detection Systematic Errors for a UCNA+ Experiment (opens in a new tab)

  10. Magnetic Spin Transport Coils for the n2EDM Experiment

    … polarization transfer efficiency of 99\% for ultracold neutrons entering or exiting the precession chamber is required, placing a stringent requirement on the adiabaticity of the magnetic field taper in the neutron guide system. The spin transport fields transition from 5~T (longitudinal) in …

    uky-thes Repository record for Magnetic Spin Transport Coils for the n2EDM Experiment (opens in a new tab)

  11. Modeling He-II cryostat performance and characterization of spin manipulation components for a neutron electric dipole moment experiment at TRIUMF

    This thesis chronicles measurements of ultracold neutrons (UCN) performed at TRIUMF in fall 2018 and fall 2019. Heat response data of the UCN source bottle was taken by measuring its temperature using the vapour pressure of the 4He. The time-dependence of the He-II bottle temperature is …

    manitoba Repository record for Modeling He-II cryostat performance and characterization of spin manipulation components for a neutron electric dipole moment experiment at TRIUMF (opens in a new tab)

  12. MEASUREMENTS OF THE BINDING ENERGIES OF IONS ON PLASTIC SURFACES IN LIQUID NITROGEN

    … plans to increase neutron density by storing ultracold neutrons in superfluid helium-4. In this experiment, the central part of the apparatus consists of two deuterated tetraphenyl butadiene (dTPB) coated poly(methyl methacrylate) (PMMA) cells, which are sandwiched between grounded and …

    uky-thes Repository record for MEASUREMENTS OF THE BINDING ENERGIES OF IONS ON PLASTIC SURFACES IN LIQUID NITROGEN (opens in a new tab)

  13. Characterization of the magnetically shielded room for the neutron electric dipole moment experiment at TRIUMF

    … |dn| < 1.8 × 10^−26 e·cm (90% C.L.). The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration aims to improve this by an order of magnitude, targeting σ(dn) ≤ 10^−27 e·cm. The standard method for nEDM measurement uses polarized Ultracold Neutrons (UCN) and the Ramsey technique of separated …

    manitoba Repository record for Characterization of the magnetically shielded room for the neutron electric dipole moment experiment at TRIUMF (opens in a new tab)

  14. A Magneto-Gravitational Neutron Trap for the Measurement of the Neutron Lifetime

    … measurements of the neutron lifetime used ultracold neutrons (UCN) confined in material bottles. In a material bottle experiment, UCN are loaded into the apparatus, stored for varying times, and the surviving UCN are emptied and counted. These measurements are in poor agreement with …

    iu Repository record for A Magneto-Gravitational Neutron Trap for the Measurement of the Neutron Lifetime (opens in a new tab)

  15. Studies of ultracold neutron dynamics and systematic effects for the TUCAN EDM experiment

    The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration is developing a new measurement of the neutron electric dipole moment (nEDM) with the goal of improving the current best limit of dn ≤ 1.8 × 10-²⁶ ecm (90% C.L.) to the level of dn ≲ 2 × 10-²⁷ ecm (90% C.L.). A non-zero nEDM requires the …

    ubc Repository record for Studies of ultracold neutron dynamics and systematic effects for the TUCAN EDM experiment (opens in a new tab) Download PDF for Studies of ultracold neutron dynamics and systematic effects for the TUCAN EDM experiment (opens in a new tab)

  16. Magnetic fields and ultracold neutron production: studies towards the neutron electric dipole moment experiment at TRIUMF

    … experimental method to measure the nEDM uses the ultracold neutrons (UCN) and employs the Ramsey method of separated oscillatory fields. In this method, the Larmor precession frequency of UCN is measured in the presence of aligned Electric and Magnetic fields orientations. Such precision …

    manitoba Repository record for Magnetic fields and ultracold neutron production: studies towards the neutron electric dipole moment experiment at TRIUMF (opens in a new tab)

  17. Guiding fields development for the TUCAN nEDM Experiment

    … The TUCAN nEDM experiment requires polarized ultracold neutrons to be stored in a volume with precisely known electromagnetic fields. To achieve high counting statistics, a large number of neutrons and high degree of neutron polarization are required. For this, the neutron polarization needs …

    ubc Repository record for Guiding fields development for the TUCAN nEDM Experiment (opens in a new tab) Download PDF for Guiding fields development for the TUCAN nEDM Experiment (opens in a new tab)

  18. Polarization and two-photon spectroscopy of xenon for optical magnetometry

    … will occupy the same experimental volume as ultracold neutrons and be used to measure drifts in an applied magnetic field. A scheme is described for optical magnetometry which involves the production of polarized ¹²⁹Xe followed by measurements using two-photon laser induced fluorescence as a …

    ubc Repository record for Polarization and two-photon spectroscopy of xenon for optical magnetometry (opens in a new tab) Download PDF for Polarization and two-photon spectroscopy of xenon for optical magnetometry (opens in a new tab)

  19. Magnetic Field Monitoring in the SNS Neutron EDM Experiment

    … signal CP violation. To look for an nEDM, stored ultracold neutrons are placed in parallel and anti-parallel magnetic and electric fields and the Larmor precession frequency is carefully measured. A difference in the precession frequency of the neutrons in the two states of the fields would signal …

    uky-thes Repository record for Magnetic Field Monitoring in the SNS Neutron EDM Experiment (opens in a new tab)