Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 35 for “"Ultrashort Echo Time"”
-
Quantifying Lung Water Density with Ultrashort Echo Time Yarn-Ball MRI
… This thesis illustrates a novel Yarn-Ball (YB) ultrashort TE (UTE) k-space trajectory along side an automated image processing approach. Efficiency optimized UTE-YB k-space trajectories were designed for breath-hold and free-breathing acquisitions. These provide full torso spatial coverage with …
-
Magnetic resonance imaging of engineered tissues: enhanced contrast and ultrashort echo time MRI
Contains fulltext : 129661.pdf (Publisher’s version ) (Open Access)
-
Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung
In this thesis, a 3D Ultrashort echo time (3D-UTE) sequence was introduced in the Self-gated Non-Contrast-Enhanced Functional Lung Imaging (SENCEFUL) framework. The sequence was developed and implemented on a 3 Tesla MR scanner. The 3D-UTE technique consisted of a nonselective RF pulse followed by …
-
MRI Quantification of Cortical Bone Microstructure and Material Composition with Ultrashort Echo Time Sequences
… in vivo in clinically practical acquisition times. Therefore, the primary objective of this dissertation was to perform the first investigation of these cortical bone parameters in patients with diagnosed bone disease, and to explore the potential clinical translatability of these techniques. …
-
Modelling the short-T2* signal in the liver with ultrashort echo time magnetic resonance imaging (UTE-MRI)
… However, collagen signal is measurable with the ultrashort echo time (UTE) sequence, which can achieve an echo time of less than 1 ms. This thesis explored the modelling of the short-T<sub>2</sub><sup>*</sup> signal in the liver with UTE.</p> <p>Given the implication of collagen in liver disease, …
-
Reducing uncertainties in image-guided radiotherapy of rectal cancer
… setup. In addition, we propose the use of an ultrashort echo time MRI sequence to visualize the applicator on MRI. Lastly, we determined the added value of a national study group meeting on the quality and variability of EBRT treatment plans for the introduction of a novel target volume that …
-
Study of UTE and ZTE Sequences at Ultra-High Magnetic Field Strengths
UTE (Ultrashort Echo Time) and ZTE (Zero Echo Time) sequences have found to detect short T2 relaxation signals coming from regions that are not detected by conventional MRI methods. Due to the high dipole-dipole interactions in solid and semi-solid tissues, the echo time generated is simply not …
-
Detailed bone assessment of the sacroiliac joint in a prospective imaging study: Comparison between computed tomography, zero echo time, and black bone magnetic resonance imaging
Objectives: To compare the value of zero echo time (ZTE) and gradient echo "black bone" (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods: Between May 2019 and January 2021, 79 patients prospectively …
-
Improving and Validating Apparent Transverse Relaxation and 129Xe Apparent Diffusion Coefficient Mapping in Murine Lungs
… the short T2* constraint can be addressed by 1H ultrashort echo time (UTE)sequences which enable imaging at echo times on the order of tens of microseconds.Additionally, imaging exogenous agents such as inhaled hyperpolarized (HP) 129Xegas overcomes low pulmonary tissue density, offering …
-
Quantitative Applications of UTE MRI in Assessing Post-Acute COVID-19
… imaging (MRI) hardware and pulse sequences (e.g. ultrashort echo-time MRI) have reduced barriers to applying MRI in the lungs, making it an ionizing radiation free alternative to CT. The utilization of normalization of MRI signal intensity units in the lung parenchyma and correction of spatial …
-
Pulse sequence design for fast and flexible sodium magnetic resonance imaging
… transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min …
-
Ultra-High Field Magnetic Resonance Imaging (MRI) Characterisation of the Functional Anatomy and 3D Structural Arrangement of Equine Superficial Digital Flexor Tendons
… utilizing the high soft tissue contrast of the ultrashort echo-time T2* weighted 3D-FISP MRI sequence was developed to facilitate the non-destructive structural assessment of a continuous SDFT segment. Based on consecutive high-resolution transverse MR images, the IFM spatial distribution and …
-
Advances in magnetic resonance imaging reconstruction methods incorporating prior knowledge
… undersampling in an effort to reduce scan times. This can lead to artefacts in the reconstructed images.<br/>In this thesis two emerging clinical applications of MRI are considered: hybrid<br/>PET-MR imaging and coronary MR angiography (CMRA). Factors giving rise to<br/>substantial …
-
Changes in UTE-T2* Relaxation Time MRI of Cartilage with Load in Individuals with Early Knee Osteoarthritis
… not detectable using conventional imaging (1–3). Ultrashort echo time (UTE) imaging enables evaluation of short T2 tissues such as the deep layer of articular cartilage (4). In addition, imaging the knee under loading conditions may enhance the detection of early osteoarthritis (OA)-related …
-
Robust Magnetic Resonance Imaging of Short T2 Tissues
Tissues with short transverse relaxation times are defined as ‘short T2 tissues’, and short T2 tissues often appear dark on images generated by conventional magnetic resonance imaging techniques. Common short T2 tissues include tendons, meniscus, and cortical bone. Ultrashort Echo Time (UTE) pulse …
-
MRI Characterization of Peripheral Arterial Disease for Planning Percutaneous Vascular Interventions
… We have developed an MRI method using ultrashort echo time and steady state free precession flow-independent imaging that characterizes hard versus soft peripheral arterial lesion components and related those characteristics to ease of crossing during PVI. We performed ex-vivo studies …
-
DEVELOPMENT AND CLINICAL TRANSLATION OF MRI METHODS FOR QUANTITATIVE ASSESSMENT OF ORGAN PHYSIOLOGY AND TISSUE STRUCTURE
… the DURANDE sequence (dual-radiofrequency, dual-echo ultrashort echo time) was quantitatively compared to other craniofacial-imaging techniques. Furthermore, DURANDE’s clinical feasibility was investigated in pediatric patients with craniofacial abnormalities. The bone-selective images were …
-
Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties
… tendon cross-sectional area, thickness, echogenicity, stiffness, and T2*) responses to loading forces are variable and measurable in vivo. These responses impact the physiologic function of the tendon. Aims: 1) To evaluate baseline Achilles tendon biomechanical characteristics associated …
-
Magnetic Resonance Imaging Techniques For Contrast - Enhanced Cellular And Molecular Imaging
… detection sensitivity offered by a Multiple-Echo Ultrashort Echo Time (MUTE) MRI technique was demonstrated. In addition, I proposed a novel method that provides robust positive contrast with high temporal efficiency to advance cellular tracking technology. The physical principles of positive …
-
MRI-based radiomics: Quantifying the stability and reproducibility of tumour heterogeneity in vivo and in a 3D printed phantom
… segmentation however was only visible with an ultrashort echo time sequence, not commonly used in SOC imaging. Chapter 5 investigates a high temperature resin (‘white resin’) where a texture object was developed for analysis. The ‘white resin’ was visible using SOC sequences. The interscanner …
Page 1 of 2