Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 126 for “"Ultrasonic transducer"”.

  1. A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer

    … presents the design of Capacitive Micromachined Ultrasonic Transducers (CMUTs) with one and multiple bottom electrodes and their fabrication using the PolyMUMPs technique provided by MEMSCAP Inc. It also reports a new behavioral model of the CMUTs written in VHDL-AMS, complemented by a comparison …

    ubc Repository record for A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer (opens in a new tab) Download PDF for A PolyMUMPs Capacitive Micromachined Ultrasonic Transducer (opens in a new tab)

  2. High-Frequency Phased Array Ultrasonic Transducer

    … there is an increasing demand on high frequency ultrasonic transducer for the purpose of observing superficial tissues and small biological structure, eyeball structure for example. Such exquisite target has high requirement on special resolution of the transducer. To achieve the goal, a high …

    unsw Repository record for High-Frequency Phased Array Ultrasonic Transducer (opens in a new tab)

  3. Capacitive micromachined ultrasonic transducer (cMUT) for biometric applications

    … imaging technique and capacitive micromachined ultrasonic transducer (cMUT) is a good choice to perform these measurements. The main advantage of cMUT is ideal design compatibility with the fingerprint sensor based on capacitive method - a product of Fingerprint Cards AB (FPC) which participates …

    chalmers Repository record for Capacitive micromachined ultrasonic transducer (cMUT) for biometric applications (opens in a new tab)

  4. Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer

    … developed and widely used in medical imaging. Ultrasonic imaging was invented to substitute the high cost ionizing radiation in magnetic resonance imaging (MRI) system, because it is portable, has low production cost and can be embedded with external circuitry in making sensing or actuating …

    texas-state Repository record for Analytical Modeling and Simulation of Capacitive Micromachined Ultrasonic Transducer (opens in a new tab)

  5. Theoretical analysis of a fractal ultrasonic transducer using renormalisation

    … imaging is employed using piezoelectric ultrasonic transducers. These sensors typically operate at a single frequency due to the restrictions imposed on their resonant behaviour by the use of a single length scale in the design. To allow these transducers to transmit and receive more …

    strathclyde Repository record for Theoretical analysis of a fractal ultrasonic transducer using renormalisation (opens in a new tab)

  6. Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer

    … moving membrane capacitive micromachined ultrasonic transducer (M3-CMUT) is fabricated and characterized in this thesis. Unlike the single vibrating membrane in the conventional capacitive micromachined ultrasonic transducer (CMUT), the novel design involves two deflectable membranes …

    manitoba Repository record for Characterization of multiple moving membrane capacitive micromachined ultrasonic transducer (opens in a new tab)

  7. Fluid-structure simulation of large micromachined ultrasonic transducer arrays

    Acoustic transducer arrays composed of a large number of flexural membranes are found in a diversity of applications such as underwater acoustics, medical therapeutics, and medical imaging. By coupling the vibration of electromechanical layers to the flexural motion of low-impedance membrane …

    gatech Repository record for Fluid-structure simulation of large micromachined ultrasonic transducer arrays (opens in a new tab)

  8. A computer technique for near-field analysis of ultrasonic transducer.

    … obtaining near-field crosssection views of an ultrasonic field is presented. The technique is applied to ultrasonic transducer radiation patterns with sample contour drawings of several crosssections. A spatial frequency spectrum formulation of diffraction theory is chosen for the computations …

    nps Repository record for A computer technique for near-field analysis of ultrasonic transducer. (opens in a new tab)

  9. Ultrasonic transducer design: Feasibility as parametric echosounder in shallow water

    … long-distance communications in the atmosphere. Ultrasonic echo sounders allow sampling of water columns and cover large areas of ocean by means of sampling campaigns conducted by oceanographic vessels, providing information on fish stocks of commercial interest. Furthermore, as a result of the …

    upv Repository record for Ultrasonic transducer design: Feasibility as parametric echosounder in shallow water (opens in a new tab)

  10. Multilayer graphene-based capacitive micromachined ultrasonic transducer design, manufacturing, and characterization

    … MLG and silicon using a capacitive micromachined ultrasonic transducer (CMUT) receiver as an exemplar MEMS sensor. Modeling showed a >4x improved mechanical compliance and bandwidth attributable to the lower mass and lower internal stress of MLG membranes. Finally, a proof-of-concept CMUT was …

    texas Repository record for Multilayer graphene-based capacitive micromachined ultrasonic transducer design, manufacturing, and characterization (opens in a new tab)

  11. Autonomous NDT – Mitigating Misalignment Effect of Inductively Coupled Ultrasonic Transducer Systems

    … health monitoring, an inductively coupled ultrasonic <br/>transducer system (ICTS) is a permanently-installed measurement sensor system that benefits from its <br/>lightweight, wireless, battery free, and low-profile design. A common application is measuring remaining wall <br/>thickness. …

    bristol Repository record for Autonomous NDT – Mitigating Misalignment Effect of Inductively Coupled Ultrasonic Transducer Systems (opens in a new tab) Download PDF for Autonomous NDT – Mitigating Misalignment Effect of Inductively Coupled Ultrasonic Transducer Systems (opens in a new tab)

  12. Modeling ultrasonic transducer in homogeneous and non-homogeneous media using DPSM method

    Modeling ultrasonic transducers is an important aspect of research in nondestructive evaluation and testing. In most nondestructive evaluation applications, the ultrasonic transducers are traditionally modeled as: (1) point sources generating spherical wave fronts (2) line sources generating …

    arizona-thes Repository record for Modeling ultrasonic transducer in homogeneous and non-homogeneous media using DPSM method (opens in a new tab)

  13. ULTRASONIC TRANSDUCER MODELING FOR ACOUSTIC MICROSCOPY & ITS APPLICATION IN BIOLOGICAL MATERIAL CHARACTERIZATION

    … and other optical techniques, MRI, acoustic and ultrasonic techniques to name a few. Ultrasound is the most popular tool for NDE. As specimens become smaller, the need for shorter wave length ultrasound increases dramatically.The use of acoustic waves in microscopy technology provides many more …

    arizona-thes Repository record for ULTRASONIC TRANSDUCER MODELING FOR ACOUSTIC MICROSCOPY & ITS APPLICATION IN BIOLOGICAL MATERIAL CHARACTERIZATION (opens in a new tab)

  14. Ultrasonic transducer characterization and transducer beam modeling for applications in nondestructive evaluation

    … the characterization of spherically focused ultrasonic immersion transducers, and the prediction of the radiated wave fields of a variety of commonly used ultrasonic transducers;When a spherically focused probe is correctly and completely characterized, its corresponding theoretical model can …

    iastate Repository record for Ultrasonic transducer characterization and transducer beam modeling for applications in nondestructive evaluation (opens in a new tab)

  15. Design and Manufacture of an Ultrasonic Transducer for Long-term High Temperature Operation

    A novel design of ultrasonic transducers suitable for high temperatures is introduced. The transducers are targeted for trouble-free continuous operation at 700-800 째C for at least two years, with sufficiently wide bandwidth to yield good temporal resolution. The design and manufacturing procedures …

    toronto-retro Repository record for Design and Manufacture of an Ultrasonic Transducer for Long-term High Temperature Operation (opens in a new tab)

  16. Simulation of a Capacitive Micromachined Ultrasonic Transducer with a Parylene Membrane and Graphene Electrodes

    … worldwide. In comparison to other methods, ultrasonic imaging is more portable and lower cost, and is becoming more accessible to remote regions where traditionally no medical imaging can be done. However, conventional ultrasonic imaging systems still rely on expensive PZT-based ultrasound …

    ucf Repository record for Simulation of a Capacitive Micromachined Ultrasonic Transducer with a Parylene Membrane and Graphene Electrodes (opens in a new tab)

Page 1 of 7