Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"Ultrasound Doppler"”.

  1. Real time ultrasound Doppler techniques for tissue motion and deformation analysis

    … research is to develop new techniques based on Doppler ultrasound to investigate and visualize changes in tissue dynamic and deformation properties due to atherosclerosis in cardiac and vascular applications. A new technique, to correct for the Doppler angle dependence for tissue motion analysis …

    edinburgh Repository record for Real time ultrasound Doppler techniques for tissue motion and deformation analysis (opens in a new tab)

  2. Pulsed ultrasonic doppler velocimetry for measurement of velocity profiles in small channels and capplilaries

    Pulsed ultrasound Doppler velocimetry proved to be capable of measuring velocities accurately (relative error less than 0.5 percent). In this research, the limitations of the method are investigated when measuring: in channels with a small thickness compared to the transducer diameter, at low …

    gatech Repository record for Pulsed ultrasonic doppler velocimetry for measurement of velocity profiles in small channels and capplilaries (opens in a new tab)

  3. Design of Non-Invasive Device to Measure Differential Flow in the Carotid Arteries

    … and non-invasive stroke detection, namely Ultrasound Doppler and Pressure Transducer. A simplified physical simulation of the human cardiovascular system was fabricated using a peristaltic pump, analog in-line flow meters, artificial carotid arteries, and water as the working fluid. A fetal …

    gvsu Repository record for Design of Non-Invasive Device to Measure Differential Flow in the Carotid Arteries (opens in a new tab)

  4. Application of Ultrasound for Bubble Measurement in Water and Mercury

    … are tested first in water, and then in mercury. Ultrasound Doppler velocity profiler directly measures bubble rise velocity, which is then used to determine bubble diameter. Ultrasonic imaging allows direct observation of the bubbles both in water and in mercury. However, challenges were …

    ut-knoxville Repository record for Application of Ultrasound for Bubble Measurement in Water and Mercury (opens in a new tab)

  5. Linear stability of a Berman flow in a channel partially filled with a porous medium

    … profile of the fluid was measured using pulsed ultrasound doppler anemometry (PUDA). Good agreement was found between the similarity numerical predications and the experimental measurements.

    ubc Repository record for Linear stability of a Berman flow in a channel partially filled with a porous medium (opens in a new tab) Download PDF for Linear stability of a Berman flow in a channel partially filled with a porous medium (opens in a new tab)

  6. Quantitative Monitoring of Tissue Fractionation by Cavitation-Based High-Intensity Focused Ultrasound

    High-intensity focused ultrasound (HIFU) can non-invasively induce cavitation within tissue, resulting in mechanical tissue damage that ranges from mild disruption with petechial hemorrhage to complete liquefaction at a subcellular scale. This capability positions HIFU as an increasingly promising …

    washington Repository record for Quantitative Monitoring of Tissue Fractionation by Cavitation-Based High-Intensity Focused Ultrasound (opens in a new tab)

  7. Hydromagnetic turbulent instability in liquid sodium experiments

    … the inner sphere and of the flow velocity using ultrasound doppler velocimetry. Our experiment is consistent with prior theory, even though our instabilities occur in the presence of preexisting hydrodynamic turbulence (the theory starts with an initially laminar flow). This result may be …

    maryland Repository record for Hydromagnetic turbulent instability in liquid sodium experiments (opens in a new tab)

  8. Observation of transition from laminar plug to well-mixed flow of fibre suspensions in Hagen-Poiseuille flow

    … work we characterize the size of the plug using ultrasound Doppler velocimetry as a function of flowrate for dilute, i.e. less than 2% consistency papermaking suspensions in a 50mm diameter pipe. The plug size was determined through analysis of local spatial and temporal variations in velocity, …

    ubc Repository record for Observation of transition from laminar plug to well-mixed flow of fibre suspensions in Hagen-Poiseuille flow (opens in a new tab) Download PDF for Observation of transition from laminar plug to well-mixed flow of fibre suspensions in Hagen-Poiseuille flow (opens in a new tab)

  9. SIMULATIONS OF NEWTONIAN AND NON-NEWTONIAN FLOWS IN DEFORMABLE TUBES

    … of the computed velocity fields with the ultrasound Doppler velocity profile measurements show good agreement, as does the adjusted pressure drop along the tube's axis. Analysis of the shear rates show that the shear-thinning effect of the fluid becomes relevant in the cross-sections with …

    mtu Repository record for SIMULATIONS OF NEWTONIAN AND NON-NEWTONIAN FLOWS IN DEFORMABLE TUBES (opens in a new tab)

  10. Computational modeling of hemodynamics and blood washout in the patient-specific left atrial appendages

    … at the mitral valve orifices are obtained from ultrasound Doppler measurement for boundary conditions. Several direct numerical simulations are carried out using a sharp-interface immersed boundary method (IBM). From the flow field analysis, it is found that the velocity and vorticity magnitude …

    jhu Repository record for Computational modeling of hemodynamics and blood washout in the patient-specific left atrial appendages (opens in a new tab)

  11. Development of Contactless Inductive Flow Tomography for Rayleigh-Bénard convection in liquid metal

    … synchronization of CIFT, temperature probes and ultrasound Doppler velocimetry (UDV). A comparison between CIFT and UDV is shown to validate the reconstructed velocities. The dissertation then focuses on the analysis of time-dependent flow dynamics, capturing transient patterns and structures …

    qucosa-diss

  12. Contrast-enhanced Doppler Ultrasound Imaging using Plane Waves

    … and vascular imaging simultaneously. In ultrasound, Doppler can visualize veins and arteries, but cannot detect the capillary level perfusion. Conversely, microbubble contrast-enhanced ultrasound imaging enables low velocity perfusion to be detected and separated from the tissue echo, but …

    toronto-retro Repository record for Contrast-enhanced Doppler Ultrasound Imaging using Plane Waves (opens in a new tab)

  13. Pathophysiology of fetal intrauterine central shunts in high-risk pregnancies : a prospective observational Doppler study.

    … of assessment during pregnancy and in labour. Doppler ultrasound is one of the tests widely used in clinical practice in the evaluation of pregnancies that are at a greater risk of developing maternal or fetal complications due to uteroplacental insufficiency. Doppler ultrasound enables …

    adelaide Repository record for Pathophysiology of fetal intrauterine central shunts in high-risk pregnancies : a prospective observational Doppler study. (opens in a new tab)

  14. New Image Processing Methods for Ultrasound Musculoskeletal Applications

    In the past few years, ultrasound (US) imaging modalities have received increasing interest as diagnostic tools for orthopedic applications. The goal for many of these novel ultrasonic methods is to be able to create three-dimensional (3D) bone visualization non-invasively, safely and with high …

    tamu Repository record for New Image Processing Methods for Ultrasound Musculoskeletal Applications (opens in a new tab)

Page 1 of 3