Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 125 for “"Ultrasound transducer"”
-
Design and analysis of capacitive micromachined ultrasound transducer
Capacitive Micromachined Ultrasound Transducers (CMUTs) have been recently introduced as a viable substitute to piezoelectric transducers in medical ultrasound imaging. CMUT possesses advantages such as allowing high frequency, having wide bandwidth, high sensitivity, low cost, CMOS compatibility …
-
A miniaturised focussed ultrasound transducer for soft tissue ablation
Focussed ultrasound surgery (FUS) in literature has been developed in the direction of large extra-corporeal transducers. With the rise of surgical robotics in recent years, a new niche is emerging in which miniaturised ultrasonic transducers for laparoscopic surgery will be required. Laparoscopic …
-
Ultrasound Transducer Arrays for Risk Stratification in Coronary Artery Disease
… coronary intervention (PCI). Intravascular ultrasound (IVUS) imaging is used to provide anatomical (morphological) imaging during PCI. However, current side-viewing IVUS does provide imaging of physiology and must cross the lesion in order to image it. Alternatively, forward-viewing IVUS …
-
Surface-micromachined Optical Ultrasound Transducer Array for 3D Photoacoustic Computed Tomography
… its combination of high optical contract at deep ultrasound penetration, which grant PACT momentum in applications like tumor diagnosis, endoscopy guidance, cancer drug development and functional brain imaging. Nevertheless, ultrasound detection remains as a bottleneck hindering the imaging …
-
Surface-micromachined Optical Ultrasound Transducer Array for 3D Photoacoustic Computed Tomography
… its combination of high optical contract at deep ultrasound penetration, which grant PACT momentum in applications like tumor diagnosis, endoscopy guidance, cancer drug development and functional brain imaging. Nevertheless, ultrasound detection remains as a bottleneck hindering the imaging …
-
Capacitive micromachined ultrasound transducer (CMUT) design and fabrication for intracardiac echocardiography
… to develop capacitive micromachined ultrasonic transducer (CMUT) arrays with novel geometry for intracardiac echocardiography (ICE) imaging along with a novel reliable CMUT fabrication process to improve the system performance. We used custom CMOS electronics and monolithically integrated our …
-
A novel EEG Artifact in the ICU: Ultrasound Transducer simulating Ictal Activity
We describe an EEG artifact seen during an ultrasound-guided central venous catheter placement that showed an evolving ictal-like electrographic pattern.
-
The Effects of ultrasound transducer velocity on intramuscular tissue temperature across a treatment site
… of this study was twofold: to determine whether ultrasound transducer velocity affected tissue temperature increase, and whether heating was uniform across the treatment site. Thermocouples were inserted 2.5cm below the skin surface at the center, edge of the ERA, and the edge of the treatment …
-
Novel Polymer Transparent Ultrasound Transducers for Photoacoustic Imaging Applications
… rich optical contrast information at deep ultrasound penetration depth not achievable with conventional optical imaging techniques. It is expected to find applications ranging from fundamental biological research to clinical diagnosis. In photoacoustic imaging, short pulsed-laser …
-
Electromechanical modeling, performance testing, and design of piezoelectric polymer film ultrasound transducers
… for accurate simulation of piezo film ultrasound transducer performance;The first part of this work describes a method for determining the piezoelectric constants and the frequency-dependent dielectric properties for the polymers, from analysis of air-loaded broadband impedance …
-
Novel ultrasonic transducers and array designs using self-similar fractal geometries
… bandwidth is an important requirement of an ultrasound transducer across many applications. Naturally occurring resonating systems utilise structures containing a range of length scales to produce a broad operating bandwidth. In this work, a novel concept of designing a piezoelectric …
-
Development of low-cost photoacoustic imaging systems and their applications
… which combines the optical contrast and the ultrasound resolution in a single imaging modality. In PAI, an object is irradiated with a short-pulsed light source. The light energy is absorbed by the object and is partially converted into heat energy, leading to local temperature rise and …
-
Design of efficient wireless power-transfer system and piezoelectric transducer for sonoporation-based drug delivery implants
… wireless power delivery and efficient small ultrasound transducer with low aspect ratio (G = length/thickness) is required to obtain high power transfer efficiency for implantable sonoporation based system. To provide power wirelessly to implantable device, resonance-based wireless power …
-
A visual comparison between the Ultrasound X6-1 Matrix transducer and MRI in lesion detection in the dome of the liver
… liver can be a very challenging area to image by Ultrasound. Due to its position inside the ribcage there can be difficulty with rib shadowing artifacts causing the sonographer to miss small lesions. The X6–1 Matrix transducer is one of the newest of its kind and claims to be the better multi-use …
-
Transperineal ultrasound image guidance system for robot-assisted laparoscopic radical prostatectomy
… evaluates the feasibility of using transperineal ultrasound for image guidance to improve visualization of anatomical structures and cancer localization during robotic prostate surgery. The proposed image guidance system utilizes a matrix array ultrasound transducer capable of real-time imaging …
-
Towards photoacoustic tomography for robot-assisted prostate imaging
… in the presence of the challenges of the linear transducers. These challenges include the directivity effect of the transducer and limited-view PA imaging that cause the rank deficiency of the reconstruction system. Therefore, a sparse representation of the PA absorber distribution using the …
-
Ultrasound elastography for intra-operative use and renal tissue imaging
… over time. These changes can be imaged with ultrasound elastography, a technique for quantitatively assessing tissue elasticity. If proven effective, elastography tissue characterization can replace biopsy. The ultrasound elastography method used in this thesis, called Shear Wave Absolute …
-
Acoustic Radiation Force Optical Coherence Elastography : Localized Vs. Wide-Area Perturbation – A Comparison
… of tissues. The experimental setup has a 10 MHz ultrasound transducer (focal length of 5cm and a spot size of 0.3mm localized excitation and unfocused for wide-area excitation) which generates acoustic radiation force (ARF) to perturb the sample and the corresponding mechanical response is imaged …
-
Automatic Arterial Wall Detection and Diameter Tracking Using M-mode Ultrasound
… lumen diameter of the artery is proposed using ultrasound radio-frequency signals acquired with a single ultrasound transducer in M-mode.Detection of the region containing the artery walls is obtained using a machine learning trained classifier. Artery lumen diameter is estimated using peak …
Page 1 of 7