Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"Underground Cable"”.
-
The optimization of cooling of underground cable systems
… of the cooling process of electric power cable system by an integral liquid coolant configuration. A model is first obtained for constant fluid velocities, by the use of Laplace transform and subsequent solution of an ordinary differential equation. A simple integral expression is …
-
Series impedance and shunt admittance matrices of an underground cable system
… impedance matrix and shunt admittance matrix of underground cable systems. In the series impedance matrix, the terms most difficult to compute are the internal impedances of tubular conductors and the earth return impedance. The various formulae for the internal impedance of tubular conductors …
-
DEVELOPMENT OF COST-EFFECTIVE FAULT LOCALIZATION PLATFORM FOR UNDERGROUND CABLE SYSTEM
… forms of electricity distribution is through underground cables, but the electricity systems regularly confront contingencies due to cable breakdowns or defects. Depending on fault types, detective tools, and cable position, it may take several hours to days to detect the exact fault location …
-
Underground cable ampacity: a fresh look at addressing the future electric grid
Underground power cables serve a critical purpose in electric power applications and the electric grid. Many have experienced the frustration of a power outage resulting from a failed cable. This dissertation addresses underground electric power cable ampacity and provides analytical, experimental, …
-
Characteristics and annealing behavior of polyethylene designed for use as underground cable insulation
… developed for use as high voltage electric cable insulation have been characterized. All crosslinked polyethylene materials show similar melting behavior, whereas linear-low-density polyethylene shows complicated melting behavior due to the variation of copolymer content. The IR …
-
A Study of Underground Cable as Applied to a Single-phase Circuit and a Paralleled Overhead-underground Single-phase Circuit
… of this country has spurred the development of underground cable. Overhead circuits, which once cluttered the landscape, are being retired and underground circuits are being installed. At new development sites, whether rural or urban, the question of installing underground circuits is being …
-
The Investigation of Tree-Retardant Ethylene Propylene Rubber Insulated Medium Voltage Cable as an Alternative Underground Cable for Victorian Power Distribution Network
Cross-linked Polyethylene (XLPE) underground cables are widely used in Victorian power distribution networks due to its lower Dielectric Dissipation Factor (DDF) over Ethylene Propylene Rubber (EPR) cable. Advancement in compounding technology led to the reduction of DDF in some EPR proprietary …
-
Study of Cables in the Distribution System: Parameters Calculation, Fault Analysis, and Configuration Optimization
Underground cables offer more advantages than overhead lines since cables are better protected and do not detract from the appearance of urban areas. In recent years, more and more electrical utilities are using cables to distribute electric power to their customers. However, the cost of …
-
Underground distribution cable incipient fault diagnosis system
… fault diagnosis system (IFDS) to detect underground cable incipient faults before they become catastrophic. The system provides vital information to help the operator with the decision-making process regarding the condition assessment of the underground cable. It incorporates advanced …
-
Flow Characteristics and Heat Transfer for Pressure and Electric Field Driven Laminar Flow With Temperature-Dependent Properties in a Pipe With Irregular Cross Section
… to solve the temperature-dependent problems of underground cable systems under pressure and/or electric fields. The temperature-dependent solutions have a large effect on the secondary flow and Nusselt number. However, it has only a minor effect on axial velocity and friction factor.
-
Electrolysis Mitigation of the Underground Telephone Cable Plant of the City of Green Bay, Wisconsin
… Bay, the track network with its relation to the underground cable sheaths of the Wisconsin Telephone Company as shown on the General Condition Map.
-
Design of the Subtransmission System connecting Vík í Mýrdal
… í Mýrdal consists primarily of a 150 mm2, 33 kV underground cable from Rimakot to Vík limited mainly by it’s ampacity. Vík í Mýrdal is also connected to the main transmission system via a 19 kV connection to Prestbakki. However, this connection has very limited capacity and is used primarily in …
-
An Electrolysis Survey of the Cumberland Telephone Co's Knoxville Underground Plant
… to determine the amount of damage to which the underground cable of the Cumberland Telephone Company at Knoxville was liable, from electrolysis due to stray currents at the time the survey was made. It deals briefly with the general principles of electrolysis, but consist chiefly of data, and an …
-
Intelligent Fault Location for Smart Power Grids
… composed of an overhead line combined with an underground cable. The proposed fault location method is utilized to overcome the difficulties introduced by the discontinuity at the transition point from the overhead line to the underground cable and the different traveling wave velocities along …
-
Characterization of real power cable defects by diagnostic measurements
… need for electric power combined with an aging underground cable infrastructure in a deregulated market environment have forced utilities to refocus their attention on reliability while at the same time reducing maintenance costs as much as possible. This has created a significant need for …
-
Partial discharge ageing of polymer insulation under combined AC and DC stress at elevated temperatures
Cable termination is the weakest part in any HV underground cable system, as defects may be left in the main insulation during the installation process. In HVDC systems, the converters produce the intended DC voltage for transmission but there may also be AC harmonics superimposed. The frequency of …
-
Multi-physics modeling of heat and particle transfer in porous media
The dissertation comprises two main components: underground duct-bank thermal dissipation considering the convection heat transfer in porous media and the filtration mechanisms of bentonite grout in porous media. In the first part, the study challenges traditional underground duct-bank design …
-
Simulation of electromagnetic transients in underground cables with frequency-dependent modal transformation matrics
… a new model to simulate the behaviour of underground cable systems under transient conditions. The new cable model belongs to the class of time-domain, frequency-dependent models, and it is directly compatible with the solution algorithm of the EMTP (Electromagnetic Transients Program). …
-
Full-space conformal mapping for the calculation of the parameters of overhead transmission lines and underground cables
… of a given overhead transmission line or underground cable in an unbounded space considering the effect of the ground. This is achieved using a two-dimensional conformal mapping technique, which consists of a modified bilinear transformation to map a semi-open half-space problem into a …
Page 1 of 3