Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 48 for “"Underground cables"”.
-
Asset Management of Underground Cables Factoring Resilience
… or assets, can be distributed on the ground and underground across a wide area. The health and age of the equipment in different parts of the system will vary depending on many factors, including the environment in which it is installed. To keep these assets operational and to maintain power …
-
Oil pressure effects in H.V. underground cables
The basis of the design of the oil system of a H.V. oil filled cable circuit is considered in particular the choice of oil feed locations along the cable route. Methods are established for determining the oil pressure tank requirements and the oil pressure response on application of step or pulse …
-
Water-Tree Modelling and Detection for Underground Cables
… dissertation studies water-tree development in underground cables, potential methods to detect water-tree location and water-tree severity estimation. The dissertation begins by developing mathematical models of water-tree using finite element analysis. The method focuses on surface-originated …
-
Electromagnetic full wave modal analysis of frequency-dependent underground cables
… calculating the frequencydependent parameters of underground cables. The method uses full wave formulation for calculating the modal electromagnetic fields and corresponding voltages and currents and then extracting frequency-dependent per unit length parameters of underground cables. The proposed …
-
Full frequency-dependent modelling of underground cables for electromagnetic transient analysis
… and stable model to simulate the behavior of underground cable systems under transient conditions. This thesis presents a new cable model (zCable model), which separates the representation of the wave propagation into two parts: a constant ideal propagation, which parameters depend only on the …
-
Simulation of electromagnetic transients in underground cables with frequency-dependent modal transformation matrics
… a new model to simulate the behaviour of underground cable systems under transient conditions. The new cable model belongs to the class of time-domain, frequency-dependent models, and it is directly compatible with the solution algorithm of the EMTP (Electromagnetic Transients Program). …
-
Configuration Optimization of Underground Cables inside a Large Magnetic Steel Casing for Best Ampacity
… losses in the steel casing and sheathed cables, for an arbitrary cables configuration, and 2) implementing an algorithm for determining the optimal cables configuration to obtain the best total ampacity. The first part involves approximating the eddy current and hysteresis losses in the …
-
Full-space conformal mapping for the calculation of the parameters of overhead transmission lines and underground cables
… of a given overhead transmission line or underground cable in an unbounded space considering the effect of the ground. This is achieved using a two-dimensional conformal mapping technique, which consists of a modified bilinear transformation to map a semi-open half-space problem into a …
-
Harmonic/Transient analysis of the RARIK distribution network
… out all overhead lines and replacing them with underground cables. Now 70% of the distribution grid of RARIK are underground cables. RARIK has noticed that the number of damaged electronics being reported to them, due to events in their grid has increased over the years. Thus, it is of great …
-
Water Tree Analysis and On-Line Detection Algorithm Using Time Domain Relectometry
… amount of overhead lines being converted to underground cables in the distribution system, the need to be able to determine the health of these underground cables becomes imperative. Since the health of underground cables cannot be determined by visual means like overhead lines, an on-line …
-
Πειραματικός και υπολογιστικός καθορισμός της έκθεσης ανθρώπων σε ηλεκτρικά και μαγνητικά πεδία
… systems equipments (overhead transmission lines underground cables transformers substations). The field intensities in the vicinity of substations are mainly determined with measurements, because their calculation is practically very difficult due to the complexity of the electrical equipment. In …
-
Study of Cables in the Distribution System: Parameters Calculation, Fault Analysis, and Configuration Optimization
Underground cables offer more advantages than overhead lines since cables are better protected and do not detract from the appearance of urban areas. In recent years, more and more electrical utilities are using cables to distribute electric power to their customers. However, the cost of …
-
Voltage sags in power distribution networks
… using surge arresters instead of spark gaps. Underground cables are superior to overhead line networks, but mixed networks having both underground cables and overhead lines in the same distribution network should be avoided. Surprisingly, the increased level of distribution automation often …
-
Technical consideration and impact of converting overhead power lines to underground power cables
… irrelevant in the development of new cities as underground cables become mandatory. Nonetheless, it is crucial to understand overhead line technology in order to model the next generation of power networks, as most of the power networks still comprise overhead lines. This field of study was …
-
Investigation of islanding operation in a small distribution network with small scale generation unit
… in 2005, overhead lines are being replaced by underground cables. However the transition to cables lead to appearance of overvoltages during islanding. In order to analyze the problem, a part of the distribution grid where the problems appeared, is studied. The study is performed in PSCAD where …
-
Aplicação de fasores dinâmicos na localização de defeitos em linhas de transmissão aéreas
… and location of fault in overhead lines and underground cables. Instead of using the traditional formulation of the dynamic phasor based on amplitude modulation, this thesis proposes to use a formulation based on frequency modulation, as it was found that the frequency modulation increases …
-
Reactive Power and Voltage Control for Northern Iceland : Assessment of Network Reinforcements
… contingency severity. However, the addition of underground cables increases capacitive reactive power leading to sustained overvoltage and underexcited operation of generators. A synchronous condenser is evaluated as a mitigation measure. A $\pm$50~MVAr unit at Bus~B4 effectively improves …
-
Maintenance and retirement of ageing power system assets and reinforcement of transmission systems with seismic risk
… failure models of ageing medium voltage underground cables and old power transformers, used for quantitative risk assessment, is a challenging task for utilities due to the lack of failure data. Using non-traditional failure models, i.e., models that incorporate components' condition data …
-
The Investigation of Tree-Retardant Ethylene Propylene Rubber Insulated Medium Voltage Cable as an Alternative Underground Cable for Victorian Power Distribution Network
Cross-linked Polyethylene (XLPE) underground cables are widely used in Victorian power distribution networks due to its lower Dielectric Dissipation Factor (DDF) over Ethylene Propylene Rubber (EPR) cable. Advancement in compounding technology led to the reduction of DDF in some EPR proprietary …
-
Transient fault location in low voltage underground distribution networks
… transient fault location in Low Voltage Underground Distribution Networks (LVUDN). A transient fault is the first stage of development of a fault condition which is indicative of a threat to power network security, but is not significant enough to trip the protection system. The proposed …
Page 1 of 3