Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"Uniformity correction"”.

  1. Uniformity correction for infrared IR-CCD camera

    … the results of a study of three types of uniformity correction schemes for an infrared camera. More specifically, a Datacube Image System was used to simulate the three uniformity correction schemes for a 320x244-element IR-CCD TV camera with PtSi Schottky-barrier detectors. The three …

    njit Repository record for Uniformity correction for infrared IR-CCD camera (opens in a new tab)

  2. Fixed Pattern Noise Non-Uniformity Correction Through K-Means Clustering

    … distributed and subsequently produces inadequate corrections. Noise correction methods that target fixed pattern noise rely on dynamically identifying present noise and adjust correction values appropriately using nearby information or general assumptions about the image’s composition. If noise …

    utahstate Repository record for Fixed Pattern Noise Non-Uniformity Correction Through K-Means Clustering (opens in a new tab)

  3. Uniformity correction for a scanned long wavelength infrared focal plane array

    … presents an alternative approach in providing uniformity correction for an infrared focal plane array by utilizing analog MOSFET circuitry. This technology is compatible with modern VLSI production and is capable of enhanced operation at cryogenic temperatures. The method presented here is a …

    ucf Repository record for Uniformity correction for a scanned long wavelength infrared focal plane array (opens in a new tab)

  4. A Time Delay and Integration Design for Focal Plane Arrays

    … four bits of gain enhanced resolution to provide uniformity correction. The output multiplexer buffer is designed to transfer the data off-plane to the external processing electronics while conserving power consumption across the plane. The methodology and rational behind each stage design is …

    ucf Repository record for A Time Delay and Integration Design for Focal Plane Arrays (opens in a new tab)

  5. Multi-wavelength infrared imaging computer systems and applications

    … implemented, including real-time two-point non-uniformity correction, thermal image pseudocoloring, PC to SUN workstation data transfer, automatic IR camera integration time control, and radiometric measurement parallel processing. A third computer system was developed for the demonstration of a …

    njit Repository record for Multi-wavelength infrared imaging computer systems and applications (opens in a new tab)

  6. Heat Transfer Studies with IR Thermography Techniques

    … Also, a new calibration and NUC (Non Uniformity Correction) has been made so that all the image corrections can be made automatically using MatLab code and LabView without any need of intermediate software. This will be explained more deeply in the report. Heat transfer experiments …

    chalmers Repository record for Heat Transfer Studies with IR Thermography Techniques (opens in a new tab)

  7. Efficient pre-segmentation filtering in MRCP

    … to inter-image and intervolume intensity non-uniformity correction, • a highly versatile adaptive smoothing filter, implemented as an oriented, scaled and shaped ellipsoid filter mask, • the downhill filter, an efficient new algorithm for morphological reconstruction by dilation, and • a novel …

    dcu Repository record for Efficient pre-segmentation filtering in MRCP (opens in a new tab)

  8. Development and Initial Evaluation of an MR Compatible Preclinical SPECT Insert for Simultaneous SPECT/MR Imaging

    … Without proper system calibration and data correction, SPECT images reconstructed from data acquired with our insert exhibit poor image quality. We developed a novel energy calibration method to identify the photopeak of the gamma photons from a Tc-99m source at all 24,320 detector pixels …

    jhu Repository record for Development and Initial Evaluation of an MR Compatible Preclinical SPECT Insert for Simultaneous SPECT/MR Imaging (opens in a new tab)

  9. Compact Lens Technologies: Curved Image Sensor and Volumetric Imaging Efficiency

    … by color leveling and 2-points or 3-points non-uniformity correction (NUC). The results are compared with original figure as a proof of concept showing the capability of the device being extended to an array.

    ucf Repository record for Compact Lens Technologies: Curved Image Sensor and Volumetric Imaging Efficiency (opens in a new tab)

  10. Polarimetric thermal imaging

    … with three internal wire grid polarizers. Non uniformity correction and radiometric calibration were performed to compensate for differences in detector response and polarizer's transmittance. The scene consisted of a heated aluminum plate in front of a large area blackbody as background. The …

    nps Repository record for Polarimetric thermal imaging (opens in a new tab)

  11. Modular gamma cameras: Improvements in scatter rejection, and characterization and initial clinical application.

    … of PMT gain. We describe and compare some uniformity correction methods used in the research group. We do the camera characterization by measuring spatial resolution and sensitivity of the modular camera and compare these characteristics to those of the commercial gamma camera. We design …

    arizona-thes Repository record for Modular gamma cameras: Improvements in scatter rejection, and characterization and initial clinical application. (opens in a new tab)

  12. Modelling the total appearance of gonio-apparent surfaces using stereo vision

    … After linearisation of camera response, spatial uniformity correction was performed to minimise the effect of uneven illumination. A characterisation method was then used to transfer the RGB to device-independent values. Two images captured under different lighting conditions were merged to …

    whiterose

  13. Design fabrication and characterization of high performance in GaAs/InP focal plane array in the 1-2.6 µm wavelength region

    … double sampling circuit, threshold non uniformity correction circuit and an output buffer stage. Integration and testing of InGaAs focal plane arrays with cut-off wavelengths of 1.7 um, 2.2 um and 2.6 um are described. The performance of the focal plane arrays was analyzed in detail and …

    njit Repository record for Design fabrication and characterization of high performance in GaAs/InP focal plane array in the 1-2.6 µm wavelength region (opens in a new tab)