Showing 1 to 20 of 86 for “"Unity power factor"”.

  1. A new unity power factor quasi-resonant induction heater

    … heating systems based upon resonant switch mode power converter techniques. The proposed three phase unity power factor induction heating system consists of two stages of power conversions. The important requirements for each stage of the power conversion of a typical induction heating system …

    southwales Repository record for A new unity power factor quasi-resonant induction heater (opens in a new tab) Download PDF for A new unity power factor quasi-resonant induction heater (opens in a new tab)

  2. Optimal current control for sub-unity power factor correction

    Switching mode power supplies (SMPS) are subject to low power factor and high harmonic distortions. Active power-factor correction (APFC) is a technique to improve the power factor and to reduce the harmonic distortion of SMPSs. However, this technique results in double frequency output voltage …

    mtu Repository record for Optimal current control for sub-unity power factor correction (opens in a new tab)

  3. A single three phase variable speed drive with unity power factor

    … from the supply are also the result of poor power factors. The converter should therefore operate at close to unit power factor. N Mohan, T Underland, W.P Robins [3].

    cape-town Repository record for A single three phase variable speed drive with unity power factor (opens in a new tab)

  4. AC/DC power conversion schemes with unity power factor and minimum harmonic distortion

    In most line-interfaced power converter applications the ac mains voltage is first rectified into a dc voltage or current, which is subsequently converted into voltages and currents of appropriate amplitude, frequency and shape to meet the load requirements. The front-end rectifier must satisfy …

    concordia Download PDF for AC/DC power conversion schemes with unity power factor and minimum harmonic distortion (opens in a new tab)

  5. Bi-directional AC-DC matrix converter with unity power factor for electric vehicle chargers

    … of EVs. EV chargers are recognized to impact the power quality of the grid when used in large quantities. This challenge is addressed in this thesis work to reduce the impact on the grid. First, this thesis reviews two rectifier configurations under steady state, dynamic state and fault …

    uoit Repository record for Bi-directional AC-DC matrix converter with unity power factor for electric vehicle chargers (opens in a new tab)

  6. Active and Reactive Power Control of Flexible Loads for Distribution-Level Grid Services

    … which means EVs could provide reactive power at any state-of-charge (SOC). This dissertation shows four-quadrant operation of EVs and aggregation of EVs for support of grid operations. First, this work develops hierarchical coordination frameworks to optimally manage active and reactive …

    mtu Repository record for Active and Reactive Power Control of Flexible Loads for Distribution-Level Grid Services (opens in a new tab)

  7. IMPLEMENTATION OF REACTIVE POWER FLOW CONTROL IN A SINGLE-PHASE MICROGRID

    Advancements have been made in the field of power electronics and particularly in energy management of microgrids. In this thesis, we present a comparison of two single-phase reactive power control strategies used to achieve a unity power factor with an energy management system in an AC microgrid. …

    nps Repository record for IMPLEMENTATION OF REACTIVE POWER FLOW CONTROL IN A SINGLE-PHASE MICROGRID (opens in a new tab)

  8. Neural network applications in the control of power electronic converters

    … widely used PI regulator for the regulation of Power Electronic converters. Neural Networks may be used to both control of and identification in a system. In general, one assumes that the mapping performed by the Neural Network can adequately represent the system's behavior over the desired …

    concordia Download PDF for Neural network applications in the control of power electronic converters (opens in a new tab)

  9. Advanced Single-Stage Power Factor Correction Techniques

    Five new single-stage power factor correction (PFC) techniques are developed for single-phase applications. These converters are: Integrated single-stage PFC converters, voltage source charge pump power factor correction (VS-CPPFC) converters, current source CPPFC converters, combined voltage …

    vt Repository record for Advanced Single-Stage Power Factor Correction Techniques (opens in a new tab)

  10. Design and analysis of an active power factor correction circuit

    The design of an active-unity power factor correction circuit with variable-hysteresis control for off-line dc-to-dc switching power supplies is described. Design equations relating the boost inductor current ripple to the circuit components selection and circuit performance arc discussed. A …

    vt Repository record for Design and analysis of an active power factor correction circuit (opens in a new tab)

  11. A resonant AC/DC converter for high frequency power distribution systems

    A Resonant AC/DC Converter for High Frequency Power Distribution Systems is presented in this thesis. The proposed converter employs a resonant network consisting of a few passive components. With this resonant network, the converter can attain close to unity power factor and very small total …

    concordia Download PDF for A resonant AC/DC converter for high frequency power distribution systems (opens in a new tab)

  12. On mitigating voltage rise in distribution networks with high solar PV penetration

    … rise (VR) is the resulting issue of reverse power flow from solar PVs, owing to their high penetration in the distribution network (DN). The main purpose of this thesis is to mitigate VR in such situation. Mitigation methods found in literature are evaluated in chapter 1 from PV-inverter and …

    unsw Repository record for On mitigating voltage rise in distribution networks with high solar PV penetration (opens in a new tab)

  13. SiC-Based High-Frequency Soft-Switching Three-Phase Rectifiers/Inverters

    … to the current industry practice, with a power rating between 10 and 30 kW, the power density are limited by silicon (Si) power semiconductor devices, which make the systems operate at only up to around 30 kHz. The emerging wide bandgap (WBG) power semiconductor devices are considered as …

    vt Repository record for SiC-Based High-Frequency Soft-Switching Three-Phase Rectifiers/Inverters (opens in a new tab)

  14. Modelling and real-time simulation of a modular bidirectional solid-state transformer for ultra-fast charging of electric vehicles

    … a three-phase MV utility network enabling high-power and ultra-fast charging capabilities for electric vehicles, with the capacity to incorporate energy storage systems at the MVDC-link. This topological configuration allows bi-directional power flow for Vehicle-to-Grid and for scalability to …

    uoit Repository record for Modelling and real-time simulation of a modular bidirectional solid-state transformer for ultra-fast charging of electric vehicles (opens in a new tab)

  15. Controlling the Vienna rectifier using a simplified space vector pulse width modulation technique

    … that the simplified SVPWM provides a low THD, unity Power-Factor (PF) and effective capacitor voltage balancing even after extreme faults. This study introduces a multilevel Power-Factor-Correction (PFC) converter in a 2-stage configuration. The first stage is the Vienna rectifier which has a …

    uoit Repository record for Controlling the Vienna rectifier using a simplified space vector pulse width modulation technique (opens in a new tab)

  16. Hardware implementation of boost power factor correction converter.

    Nowadays, there has been an increasing demand of unity power factor in electrical power sector. Due to the nonlinear nature of load equipment, switching devices, source voltage and current are out of phase with each other. Many power converters topologies are used for the power factor correction. …

    louisville Repository record for Hardware implementation of boost power factor correction converter. (opens in a new tab)

  17. A Novel Arc Welding Power Supply with Improved Power Factor Correction

    … design and development of a novel Arc Welding Power Supply utilizing a modified two-switch forward converter topology. The proposed design improves the power quality by improving power factor to near unity and reducing total harmonic distortion. State space analysis of the proposed circuit …

    calpoly Repository record for A Novel Arc Welding Power Supply with Improved Power Factor Correction (opens in a new tab)

  18. A Generalized Instantaneous Nonactive Power Theory for Parallel Nonactive Power Compensation

    <p>Although the definitions of active power and nonactive power in a three-phase sinusoidal power system have been accepted as a standard, it has been an issue on how to define instantaneous nonactive power in power systems with non-sinusoidal or even non- periodic voltage and/or current.</p> …

    utk-theses Repository record for A Generalized Instantaneous Nonactive Power Theory for Parallel Nonactive Power Compensation (opens in a new tab)

  19. A constant extinction angle control for a magnetohydrodynamic generator inverter system

    … to provide efficient, economical, and reliable power conversion from the direct current output of magnetohydrodynamic generators to the alternating current of an AC power grid. A study was made on inverter systems and the current-fed line-commutated inverter (CFLCI) was found to be the most …

    ut-knoxville Repository record for A constant extinction angle control for a magnetohydrodynamic generator inverter system (opens in a new tab)

  20. Reactive power compensation using an energy management system

    … and reduced energy efficiency is the reactive power demand on the grid. Inductive power demand reduces power factor, increases energy losses during transmission, limits real power supplied to the consumer, and results in higher costs to the consumer. Compensating for a reactive power demand on …

    nps Repository record for Reactive power compensation using an energy management system (opens in a new tab)