Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"Unity power factor operation"”

  1. Neural network applications in the control of power electronic converters

    … widely used PI regulator for the regulation of Power Electronic converters. Neural Networks may be used to both control of and identification in a system. In general, one assumes that the mapping performed by the Neural Network can adequately represent the system's behavior over the desired …

    concordia

  2. Design and implementation of a 130KW, 750VDC bidirectional PWM rectifier supplied from 400V, 50HZ grid

    … was made in the scope of this thesis study. Power losses of SiC MOSFET and Si IGBT having same voltage and current ratings were analyzed. Selection criteria of all materials used in rectifier panel was explained in detail. Unity power factor operation, bidirectional power flow, pure …

    metu Repository record for Design and implementation of a 130KW, 750VDC bidirectional PWM rectifier supplied from 400V, 50HZ grid (opens in a new tab)

  3. Advanced digital resonant control techniques for grid-connected voltage source converters

    It is a fact that the presence of power distributed generation sources in the electrical sector is growing exponentially worldwide. This can mainly be explained by the increase of renewable energy production, which involves principally grid-connected single- and three-phase Voltage Source …

    barcelona Repository record for Advanced digital resonant control techniques for grid-connected voltage source converters (opens in a new tab)

  4. Analysis, design and control of grid connected three phase pulse width modulated AC-DC converter

    The increasing penetration of line-commutated power diode and thyristor rectifiers into the grid power system is becoming a problem in transmission and distribution lines due the harmonic and reactive currents they inject to the grid system. Therefore, three-phase pulse width modulation (PWM) ac-dc …

    newfoundland Repository record for Analysis, design and control of grid connected three phase pulse width modulated AC-DC converter (opens in a new tab)

  5. Performance Improvement of Doubly Fed Induction Generator-based Wind Energy Conversion System during Various Internal Converter Faults

    … the LVRT capability of the DFIG and maintain its unity power factor operation during various voltage source converter (VSC) faults. To introduce a general and robust controller that helps to enhance the system’s performance under various faults, the controller parameters are tuned using the Nelder …

    unsw Repository record for Performance Improvement of Doubly Fed Induction Generator-based Wind Energy Conversion System during Various Internal Converter Faults (opens in a new tab)

  6. Power Electronic Transformer with Open-End Winding Electric Drive for Wind Energy Conversion Systems

    Power Electronic Transformers (PETs) provide a reduction in size over line frequency transformers by operating at much higher frequencies than line frequency or grid frequency. Due to their smaller size, they could be useful in renewable energy systems where an interface with the grid is needed. As …

    umn Repository record for Power Electronic Transformer with Open-End Winding Electric Drive for Wind Energy Conversion Systems (opens in a new tab)

  7. Advanced control of microgrids with renewables

    … smart grids to improve the energy efficiency and power reliability. There are two main features of the microgrid: It can be locally controlled, and it can be operated in grid-connected or islanded mode. Nowadays, more and more renewable energies are connected to the microgrid, since renewable …

    ttu Repository record for Advanced control of microgrids with renewables (opens in a new tab) Embargoed until 2027-08-01

  8. Integrated on-board battery chargers for EVs based on multiphase machines and power electronics

    … considered. In the former group the charging power rating cannot exceed the limit set by the single-phase mains. Therefore, the topologies are characterised with low charging powers, leading to a long duration of the charging process. Although the topologies supplied form three-phase mains are …

    liverpool-jm Repository record for Integrated on-board battery chargers for EVs based on multiphase machines and power electronics (opens in a new tab)

  9. A GENERALIZED CONTROL METHOD FOR CONSTANT SWITCHING FREQUENCY THREE PHASE PWM BOOST RECTIFIER UNDER EXTREME UNBALANCED OPERATION CONDITION

    … extremely unbalanced operating conditions in the power system. The proposed analytical method is verified by using MATLAB/ Simulink model developed under severe unbalanced conditions of input source voltages and input impedances. The closed loop control method for controlling the output DC voltage …

    ohiolink Repository record for A GENERALIZED CONTROL METHOD FOR CONSTANT SWITCHING FREQUENCY THREE PHASE PWM BOOST RECTIFIER UNDER EXTREME UNBALANCED OPERATION CONDITION (opens in a new tab)

  10. Investigation of power converters for AC and DC power collection in wind turbine systems

    … fossil fuel. With the overall increase in wind power production, individual wind turbines are also getting bigger producing power rating as high as 20 MW. WTSs are a complex electro-mechanical system, and as the wind turbines are getting bigger, vibration issues are becoming one of the …

    nanyang Repository record for Investigation of power converters for AC and DC power collection in wind turbine systems (opens in a new tab)

  11. Power loss management for modular multilevel converters

    … converters (VSCs) are implemented in modern power systems, such as the interface to integrate renewable energy sources (RES), and variable speed electric motor drives. Also, in the applications such as high voltage direct current (HVDC) systems and flexible alternating current transmission …

    nanyang Repository record for Power loss management for modular multilevel converters (opens in a new tab)