Discharge Coefficient Performance of Venturi, Standard Concentric Orifice Plate, V-Cone, and Wedge Flow Meters at Small Reynolds Numbers
… area for the Venturi, standard orifice plate, V-cone, and wedge flow meters. The Computational Fluid Dynamics (CFD) program FLUENT© was used to perform the research, while GAMBIT© was used as the preprocessing tool for the flow meter models created. Heavy oil and water were used separately as the …
-
Measurement of total hydrocarbon emissions with MEMS using a portable FID and a novel exhaust flow meter
… 3030PM hydrocarbon analyzer and McCrometer's V-Cone flow meter. The Signal Model 3030PM analyzer uses a heated flame ionizing detection scheme to measure hydrocarbons. The V-Cone is an obstructive, differential pressure flow meter that reshapes the flow profile, therefore conditioning the …
-
Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
… plate to the standard orifice plate and V-Cone for two-phase flows of water and air at various qualities, flow rates, and pressures are shown visually. The effect of oil as it flows through a slotted orifice plate and standard orifice plate are visually documented. The effect of …
-
Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters
… types of Venturi meters, a wedge meter, a V-cone meter, an electromagnetic flow meter, and an ultrasonic flow meter. The characteristics researched in this study are discharge coefficient (Cd) over a range of Reynolds numbers (Re), head loss across each flow meter, life, and cost of meter. …
-
Characterization of Flow Homogeneity Downstream of a Slotted Orifice Plate in a Two-Phase Flow Using Electrical Resistance Tomography
… than a standard orifice plate and a V-cone. However, the location downstream of the slotted orifice plate where the two-phase flow becomes most homogeneous is still not known. Knowing this would help in accurate flow metering of the two-phase flow as the sensors (such as the electrical …
-
The Effects of Pipewall Offsets on Water Meter Accuracy
… meters: classical Venturi, Halmi Venturi Tube, V-cone, and the wedge meter. Each meter was tested for accuracy with ten different pipe schedules installed upstream forming a pipewall offset varying between +0.125 inches and 0.937 inches. Ten flow rates between 400gpm and 6,550gpm were considered …