Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 20 for “"VASCULAR PROSTHESIS"”

  1. The mechanical design aspects of a small diameter vascular prosthesis

    Failure of medium to small diameter vascular grafts is believed to be in part due to the compliance mismatch between the native artery and the implanted graft. Consequently, designers are examining the use of more compliant materials for their manufacture. Ether free polyurethanes are currently …

    cape-town Repository record for The mechanical design aspects of a small diameter vascular prosthesis (opens in a new tab)

  2. The effects of twist on pressure through a teflon vascular prosthesis

    <p>A closed loop fluid system was developed which mimics the flow curve in the human circulatory system in order to test the effects of pressure drop and flow velocity on artificial arterial implants. This device consists of a piston pump connected to a microcomputer controlled servo-motor. Fluid …

    njit Repository record for The effects of twist on pressure through a teflon vascular prosthesis (opens in a new tab)

  3. Development of a numerical tool for the optimisation of vascular prosthesis towards physiological compliance

    It has been proposed that if a vascular prosthesis is to more closely approximate the mechanical behaviour of a native vessel, it should similarly feature a multi-component structure. One of the components could be a metal support structure, similar to an endovascular stent. The objective of the …

    cape-town Repository record for Development of a numerical tool for the optimisation of vascular prosthesis towards physiological compliance (opens in a new tab)

  4. Modeling and optimization of heparinized collagenous surfaces

    … (less than 6 mm diameter) (Parsonnet, 1976) vascular prosthesis which will remain functional while serving as a suitable interposition in the circulatory system.

    ttu Repository record for Modeling and optimization of heparinized collagenous surfaces (opens in a new tab)

  5. Antiseptikų veiksmingumo palyginimas veikiant Staphylococcus aureus infekuotą austą kraujagyslės protezą in vitro ir in vivo /

    Prosthetic vascular graft infection remains a great challenge in vascular surgery. Unsuccessful treatment of vascular prosthesis infection often results in limb amputations and death. A conservative treatment option – local wound irrigation with antiseptic solutions – it not yet a well established …

    vilnius Repository record for Antiseptikų veiksmingumo palyginimas veikiant Staphylococcus aureus infekuotą austą kraujagyslės protezą in vitro ir in vivo / (opens in a new tab)

  6. The comparison of the efficacy of the antiseptic solutions in treatment of Staphylococcus aureus infected woven vascular graft in vitro and in vivo /

    Prosthetic vascular graft infection remains a great challenge in vascular surgery. Unsuccessful treatment of vascular prosthesis infection often results in limb amputations and death. A conservative treatment option – local wound irrigation with antiseptic solutions – it not yet a well established …

    vilnius Repository record for The comparison of the efficacy of the antiseptic solutions in treatment of Staphylococcus aureus infected woven vascular graft in vitro and in vivo / (opens in a new tab)

  7. A Vascular Graft On-a-Chip Platform for Assessing Thrombogenicity with Tuneable Flow and Surface Conditions

    Vascular grafts are essential for the management of cardiovascular disease. However, the lifesaving potential of these devices is undermined by thrombosis arising from material and flow interactions on the blood contacting surface. To combat this issue, the use of antithrombogenic coatings has …

    mcmaster Repository record for A Vascular Graft On-a-Chip Platform for Assessing Thrombogenicity with Tuneable Flow and Surface Conditions (opens in a new tab)

  8. Cell-free cryopreserved arterial allografts from multiorgan donors: a new strategy to fabricate artificial blood vessels suited for peripheral vascular surgery

    … approach is infrainguinal bypass. Synthetic vascular prosthesis, are good conduits in high-flow low-resistance conditions but have difficulty in their performance as small diameter vessel grafts. A new approach is the use of native decellularized vascular tissues. Cell-free vessels are …

    bologna Repository record for Cell-free cryopreserved arterial allografts from multiorgan donors: a new strategy to fabricate artificial blood vessels suited for peripheral vascular surgery (opens in a new tab)

  9. Computational Investigation of Potential Failure Modes in Arterial Hemodynamic Flowpath

    … change of flow path wall stiffness due to the vascular prosthesis, is estimated by analysis of the corresponding edge effects for the stress components in arterial wall. In case of the composite stent material (reinforced elastollan) an optimal orthotropy is calculated and interpreted. Arterial …

    rit Repository record for Computational Investigation of Potential Failure Modes in Arterial Hemodynamic Flowpath (opens in a new tab)

  10. Engineering Poly(Ethylene Glycol) Hydrogel Scaffolds to Modulate Smooth Muscle Cell Phenotype

    … may facilitate the regeneration of functional vascular tissue as part of a tissue engineered blood vessel (TEBV) and may mitigate SMC intimal hyperplasia, which is one of the common modes of vascular prosthesis failure. A photopolymerizable poly(ethylene glycol) diacrylate (PEGDA) hydrogel …

    ohiolink Repository record for Engineering Poly(Ethylene Glycol) Hydrogel Scaffolds to Modulate Smooth Muscle Cell Phenotype (opens in a new tab)

  11. The immune response in Q fever.

    … mainly manifests as endocarditis, infection of vascular prosthesis or aortic aneurysms, or both. We studied the immune response against C. burnetii in blood of healthy individuals, chronic Q fever patients and people with a past Q fever infection. Immune cells of chronic Q fever patients showed …

    radboud Repository record for The immune response in Q fever. (opens in a new tab)

  12. Conception et caractérisations mécaniques et biologiques de substituts artériels de petit diamètre

    Il n'existe pas aujourd'hui de matériel vasculaire prothétique pour la chirurgie d'urgence de remplacement de vaisseaux de petit diamètre malades ou abîmés, voire détruits, par accident, dans l'attente d'une greffe thérapeutique pérenne. Les travaux réalisés dans cette étude exposent le …

    star-france Repository record for Conception et caractérisations mécaniques et biologiques de substituts artériels de petit diamètre (opens in a new tab) Restricted access

  13. Langzeiterfahrungen mit der silberazetatbeschichteten Polyesterprothese - Ist der prophylaktische Einsatz gerechtfertigt?

    Was ist Silber wert? Langzeiterfahrung mit der Silberacetat-beschichteten Polyesterprothese EINLEITUNG: Nicht nur zur Behandlung von Protheseninfekten, sondern auch zur Prophylaxe wurden neue silberacetat-beschichtete Gefäßprothesen entwickelt. Die hier vorliegende Studie beschreibt die Sicherheit, …

    wurz-thes Repository record for Langzeiterfahrungen mit der silberazetatbeschichteten Polyesterprothese - Ist der prophylaktische Einsatz gerechtfertigt? (opens in a new tab)

  14. Analýza a ověření metody měření průtoku krve v cévní protéze pomocí triboelektrických materiálů

    Tato diplomová práce se zaměřuje na problematiku triboelektrických nanogenerátorů (TENG) a možnosti využít je jako zdroje energie získané pohyby cévní protézy, a tím analyzovat průtok krve cévní protézou. První část práce se věnuje literární rešerši v oblasti kardiovaskulárního systému. Dále se …

    brno-tech Repository record for Analýza a ověření metody měření průtoku krve v cévní protéze pomocí triboelektrických materiálů (opens in a new tab)

  15. Evaluation du traitement antibiotique des infections de prothèse vasculaire à Staphylococcus aureus : apport d'un modèle murin

    Les infections de prothèses vasculaires (IPV) sont des maladies particulièrement graves. Malgré une fréquence finalement assez importante, elles demeurent mal connues. Staphylococcus aureus en est l’agent responsable principal. Les données concernant le traitement antibiotique à administrer pour …

    star-france Repository record for Evaluation du traitement antibiotique des infections de prothèse vasculaire à Staphylococcus aureus : apport d'un modèle murin (opens in a new tab)

  16. Utilisation d'une décharge à barrière diélectrique pour développer une matrice polymère plasma dégradable pour des applications vasculaires

    Chaque année, environ 1,5 million de patients requièrent un remplacement vasculaire en réponse à une athérosclérose avancée, causant le rétrécissement interne des vaisseaux sanguins. Malheureusement, encore aujourd'hui les matériaux synthétiques utilisés pour remplacer les artères de petits …

    star-france Repository record for Utilisation d'une décharge à barrière diélectrique pour développer une matrice polymère plasma dégradable pour des applications vasculaires (opens in a new tab)

  17. Mechanical optimization of vascular bypass grafts

    Synthetic vascular grafts are useful to bypass diseased arteries. The long-term failure of synthetic grafts is primarily due to intimal hyperplasia at the anastomotic sites. The accelerated intimal hyperplasia may stem from a compliance mismatch between the host artery and the graft since …

    gatech Repository record for Mechanical optimization of vascular bypass grafts (opens in a new tab)